![Delta Membranes PowerMaxx2 Installation & Operating Manual Download Page 12](http://html1.mh-extra.com/html/delta-membranes/powermaxx2/powermaxx2_installation-and-operating-manual_2478263012.webp)
16.0 AlertMaxx2 wiring schematic
Figure 5. AlertMaxx2 wiring schematic
PRIMARY
SECONDARY
AlertMaxx2 High Level Alarm
(DMS-298)
For internal wiring of the high
level alarm, please refer to the
AlertMaxx2 instruction manual.
- The pump is supplied with a 10m cable.
- When only using the standard 10m
cable attached to the pump, the cable
duct should be no longer than 6m.
- If the cable duct requires to be longer
than 6m, please follow the cable
extension guide to select an appropriate
cable core diameter.
Finger Float Switch
The electrical installation must comply with the requirements of
BS 7671:2008 ‘Requirements for
Electrical Installations’ incorporating amendment 3:2015
Separate 16 Amp RCBO’s
13 Amp Non-switched
fused spurs
Secondary
From Mains
Primary
From Mains
Primary To Pump/
AMX2 Mains In
Secondary To Pump/
AMX2 Mains In
MaxxConnect Cable
PowerMaxx2 Battery Backup
(DMS-280-1)
For internal wiring of the battery
backup, please refer to the
PowerMaxx instruction manual.
12