![Delta Elektronika INT MOD ANA Manual Download Page 15](http://html1.mh-extra.com/html/delta-elektronika/int-mod-ana/int-mod-ana_manual_2478112015.webp)
11
TROUBLE SHOOTING
11.1
INTERFACE IS NOT DETECTED
•
Check the interface is in slot 2, 3 or 4, not in slot 1.
•
Check that there is only one simulation interface installed, and no analog interface.
•
Check the firmware version as specified in chapter 3.3
11.2
INTERFACE IS PROGRAMMING ZERO
•
Check the power supply programming source is the correct slot.
•
Check the simulation interface is in the corresponding simulation type and simulation mode.
•
Check the simulation interface configuration. When the simulation type has been changed, all settings are cleared to pre-
vent unpredictable behavior.
11.3
INTERFACE DOES NOT CORRECT THE OUTPUT VOLTAGE OR CURRENT
•
Check if the simulation type is enabled.
•
Check the simulation interface settings.
SM3300 INTERFACES
DELTA ELEKTRONIKA BV
May 2013
Page 3 - 5
fig. 3 - 6
Foldback