background image

14

Infrasuite Power Management

No.

Item

Description

7

Test 

LED

Green. If you press the test button, the STS will be under 

test and the Test LED will flash (on: 0.5s; off: 0.5s). In normal 

operation, the LED will be off. 

8

Fault 

LED

Red. If the STS has any internal fault, the LED will light up as 

red. If the STS has any environmental fault, the LED will flash 

(on: 0.5s; off: 0.5s). Via the 

NETWORK

 port, fault messages 

will be sent to a connected PC. From the PC, you can see 

error codes as follows.

Environmental Fault 

Error Code

Meaning

E01

Output overload

E02

Over temperature (due to detection of 
ambient temperature)

E03

Over temperature warning (due to 
detection of S1 heat-sink temperature)

E04

Over temperature warning (due to 
detection of S2 heat-sink temperature)

Internal Fault

Error Code

Meaning

E11

Over temperature (due to detection of S1 
heat-sink temperature)

E12

Over temperature (due to detection of S2 
heat-sink temperature)

E13

Auxiliary power 1 circuit failure

E14

Auxiliary power 2 circuit failure

E21

Input relay of S1 is open

E22

Input relay of S1 is short

E23

Input relay of S2 is open

E24

Input relay of S2 is short

E25

Input SCR of S1 is open

E27

Input SCR of S2 is open

Summary of Contents for STS30002SR00035

Page 1: ...nfrasuite Power Management User Manual The power behind competitiveness Static Transfer Switch TEST O P S1 S1 ON S2 S2 ON RESET NETW ORK TEST O P S1 S1 ON S2 S2 ON NETW ORK RESET LOCA L TEST O P S1 S1...

Page 2: ...f this product Any disposition duplication dissemination reproduction modification translation extraction or usage of this Manual in whole or in part is prohibited without the prior written permission...

Page 3: ...Model Type 5 Chapter 3 Installation 7 3 1 Installation_Model STS30002SR00035 7 3 2 Installation_Model STS30002SR10035 8 3 3 Installation_Model STS30002SR10135 9 Chapter 4 Wiring 10 4 1 Wiring_Model S...

Page 4: ...ent 7 3 Top View and Front View of SNMP IPv6 19 7 4 Console Management 20 7 5 Upgrade 24 7 6 STS Command Settings 26 7 7 Key Generation for SSH 30 Chapter 8 Troubleshooting 32 Appendix 1 Specification...

Page 5: ...cts from getting inside the unit 7 Do not operate the unit close to gas or fire z z Upstream circuit breaker must be added for each input The recommended break er is D curve 30A for STS30002SR00035 an...

Page 6: ...R 22 Class A and FCC Class A z z EMS IEC 61000 4 2 IEC 61000 4 6 IEC 61000 4 3 IEC 61000 4 8 IEC 61000 4 4 IEC 61000 4 11 IEC 61000 4 5 z z IPv6 Certification IPv6 Ready Logo Phase 2 Core for Host Log...

Page 7: ...and STS s status from the front panel s LED indi cators and monitor the STS via the built in InsightPower SNMP IPv6 card The unit has a network interface for the user to read and write parameters and...

Page 8: ...whom you purchased the unit 2 If the STS needs to be returned carefully repack the STS and all of the accessories using the original packing material that came with the unit 2 3 Features z z Flexible...

Page 9: ...ctures Model No Input Output Type Length Type Length STS30002SR00035 L6 30P 3600mm 12 feet L6 30R 450mm 18 inches STS30002SR10035 IEC309 32A 4000mm IEC309 32A 1000mm STS30002SR10135 HP T4049S 3P L2 N...

Page 10: ...6 Infrasuite Power Management z z Model STS30002SR10035 TEST O P S1 S1 O N S2 S2 O N NETW ORK RESE T LOCA L z z Model STS30002SR10135 TEST O P S1 S1 O N S2 S2 O N NETW ORK RESE T LOCA L...

Page 11: ...odel STS30002SR00035 z z Front installation TEST O P S1 S1 ON S2 S2 ON NETWORK RESET LOCAL z z Rear installation TEST O P S1 S1 ON S2 S2 ON NETWORK RESET LOCAL NOTE After installation the surplus four...

Page 12: ...0002SR10035 z z Front installation TEST O P S1 S1 ON S2 S2 ON NETWORK RESET LOCAL z z Rear installation TEST O P S1 S1 ON S2 S2 ON NETWORK RESET LOCAL NOTE After installation the surplus four bracket...

Page 13: ...2SR10135 z z Front installation TEST O P S1 S1 ON S2 S2 ON NETWOR K RESET LOCAL z z Rear installation TEST O P S1 S1 ON S2 S2 ON NETWORK RESET LOCAL NOTE After installation the surplus four bracket sc...

Page 14: ...3 Connect the Ethernet cable not provided to the front panel s NETWORK port To Source 1 T o S o u r c e 2 T o L o a d TEST O P S1 S1 O N S2 S2 O N RES ET NET WOR K LOC AL 4 2 Wiring_Model STS30002SR1...

Page 15: ...urce 1 T o S o u r c e 2 T o L o a d TEST O P S1 S1 O N S2 S2 O N NETW ORK RES ET LOC AL 4 3 Wiring_Model STS30002SR10135 1 Remove the two screws shown in the figure below TE ST O P S1 S1 ON S2 S2 ON...

Page 16: ...ect the wiring terminals and the source 1 S1 source 2 S2 and your load For wiring please refer the figure below Please note that source 1 S1 is the preferred source Wiring Terminal Location L N G Wire...

Page 17: ...light up as green If the input source 2 is out of the acceptable range the LED will be off 3 S1_ON LED Green If the STS uses input source 1 to supply power to the output the LED will light up as green...

Page 18: ...onmental Fault Error Code Meaning E01 Output overload E02 Over temperature due to detection of ambient temperature E03 Over temperature warning due to detection of S1 heat sink temperature E04 Over te...

Page 19: ...twork communication status STS LED amber indicates the STS s communication status NETWORK NET LED STS LED LED Condition Meaning ALL Blinking Rapidly Firmware is upgrading NET LED OFF Ethernet is unlin...

Page 20: ...The built in SNMP IPv6 provides the STS s status information and parameters through a network system OFF ON Pass Through Mode The built in SNMP IPv6 stops polling the STS but transfers the communicat...

Page 21: ...ensitive equipment L N G 2 poles circuit breaker STS L N G S1 S2 L1 N1 G L2 N2 G After power connection the STS will automatically perform power on self test After the test the STS will start supplyin...

Page 22: ...nd manage your STS via the SNMP IPv6 7 2 SNMP IPv6 Features z z Network STS management Allows remote management of the STS from any workstation through Internet or Intranet z z Remote STS monitoring v...

Page 23: ...rough syslog IPv6 Ready Logo certified ID 02 C 000624 DEFAULT SETTING User Name admin Password password DHCP Client Enable IPv4 Address 192 168 1 100 7 3 Top View and Front View of SNMP IPv6 z z Top V...

Page 24: ...1f MAC Address 00 30 ab 26 b1 b4 1 User Manager 2 TCP IP Setting 3 Network Parameter 4 Time Server 5 Soft Restart 6 Reset All To Default d Device Communication z Exit Without Save 0 Save And Exit Plea...

Page 25: ...ion e Auto Negotiation Enable f Speed 100M g Duplex Full h Status Stable 3 i Telnet Idle Time 60 Seconds 0 Back To Previous Menu Please Enter Your Choice TCP IP Setting z z Network Parameter 1 HTTP Se...

Page 26: ...Back To Previous Menu Please Enter Your Choice Time Server z z Soft Restart Web Card Version 01 12 11f MAC Address 00 30 ab 26 b1 b4 1 User Manager 2 TCP IP Setting 3 Network Parameter 4 Time Server...

Page 27: ...bs2p 180 0 STS Tdp2s 12 0 STS Tds2p 12 0 STS TempF 96 STS TempC 36 STS Age 1075878 STS Time 13 3 24 07 18 2011 STS XCount 4402 STS Prefer S1 STS DevID 12345678901234567890 STS Serial STS Tprevl 13 35...

Page 28: ...tart after finishing self upgrade If you upload the STS s firmware to the Web you can see the STS s firmware upgrade progress from the Web z z Upgrade via FTP SFTP You can also upgrade the SNMP IPv6 s...

Page 29: ...rade via EzSetting You can also upgrade the SNMP IPv6 s firmware or the STS s firmware by using EzSetting 1 Click Discover A list of SNMP devices is shown Select a device from the Device List and clic...

Page 30: ...t summary information N A Command response unit TempF Report internal STS fahrenheit temperature N A TempC Report internal STS celsius temperature N A Age Report internal STS age N A Time Report prese...

Page 31: ...Report the output voltage N A Iout Report the output current N A Vs1 Report the primary voltage N A Vs2 Report the secondary voltage N A Fs1 Report the primary frequency N A Fs2 Report the secondary...

Page 32: ...Mts2 Report the max time of comparing cycles for secondary AC blackout N A Log Report the event code and time of prior transfers 1 10 hh mm ss MM DD YYYY 0x Tprev 1 9 Report the time of prior transfe...

Page 33: ...s Set the recover time of transfer from primary to secondary 12 0 1800 0 Various kinds SetTds2p Set the recover time of transfer from secondary to primary 12 0 1800 0 Various kinds SetMvs1 Set the max...

Page 34: ...B XXX Link Check current Modbus connection N A 1 Normal 2 Abnormal 3 Upgrading Bye Terminate remote connection N A Various kinds 7 7 Key Generation for SSH z z For Linux 1 Please download and install...

Page 35: ...y and assign a file name to the RSA key Please ignore it when prompted to provide key passphrase 5 Select SSH 2 DSA from the Parameters area and select Key Generate key pair to generate a DSA key 6 Se...

Page 36: ...ers S1 or S2 LED is off The corresponding power source is absent or out of range 1 Check the corresponding power source 2 Reset the corresponding upstream circuit breaker Fault LED flashes Output over...

Page 37: ...440mm x 385mm STS30002SR10135 43mm x 440mm x 390mm Weight STS30002SR00035 7 7Kg STS30002SR10035 7 6Kg STS30002SR10135 6 2Kg Environment Operating temperature 0 40 C Storage temperature 15 50 C Humidit...

Page 38: ...on usage maintenance or irresistible force i e war fire natural disaster etc and this warranty also expressly excludes all incidental and consequential damages Maintenance service for a fee is provide...

Page 39: ......

Page 40: ...5013212302...

Reviews: