PG-02 Terminal Descriptions 

Terminals 
 

Terminal Symbols 

Descriptions 

VP 

Power source of PG-02 (FSW1 can be switched to 12V or 5V)   
Output Voltage: (+12VDC 

±

5% 200mA) or (+5VDC 

±

2% 400mA) 

DCM 

Power source (VP) and input signal (A, B) common 

 

Input signal from Pulse Generator. Input type is selected by FSW2. 
Maximum 500KP/Sec   

A/O, B/O 

PG-02 output signal for use with RPM Meter. 
Maximum DC24V 300mA 

COM 

PG-02 output signal (A/O, B/O) common. 

 

Wiring Notes 

 

The control, power supply and motor leads must be laid separately. They 
must not be fed through the same cable conduit / trunking. 
 

1.  Please use a shield cable to prevent interference. Do not run control wire parallel to any 

high voltage AC power line (220 V and up). 

2.  Connect shielded wire to 

 E only.  

3.  Recommended wire size 0.21 to 0.81mm

(AWG24 to AWG18). 

4. Wire 

length: 

Types of Pulse 

Generators 

Maximum Wire Length

Wire Gauge 

Output Voltage 

50m 

Open Collector 

50m 

Line Driver 

300m 

Complementary 70m 

1.25mm

(AWG16) or above 

 

 