background image

 

 

 

DELTA ELECTRONICS, INC.

 

12 Jun., 

2007

Rev. 0F

www.deltaww.com

 

P

S

: Sensitivity optical power of receiver. 

5)  Byte 95 contains the low order 8bits of sum of bytes 0-94. 
6) 

State/ Control Bits 

Byte 

 Bit 

Name 

Description 

110 

Tx Disable State 

Digital state of the Tx disable input pin 

110 

Soft Tx Disable 

Read/ Write bit that allow software disable of laser 

110 5 

Reserved 

 

110 

Rate Select tate 

NA 

110 

Soft Rate Select 

NA 

110 

Tx Fault 

Digital state of the Tx fault output pin 

110 1 

LOS 

Digital 

state 

of the LOS output pin. 

110 

Data_Ready_Bar 

NA 

7) 

Optional Set of Alarm and Warning 

Byte 

 Bit 

Name 

Description 

112 

Temp High Alarm 

Set when internal temperature exceeds high alarm level 

112 

Temp Low Alarm 

Set when internal temperature is below low alarm level 

112 

Vcc High Alarm 

Set when internal supply voltage exceeds high alarm level 

112 

Vcc Low Alarm 

Set when internal supply voltage is below low alarm level 

112 

Tx Bias High Alarm 

Set when Tx Bias current exceeds high alarm level 

112 

Tx Bias Low Alarm 

Set when Tx Bias current is below low alarm level 

112 

Tx Power High Alarm 

Set when Tx output power exceeds high alarm level 

112 

Tx Power Low Alarm 

Set when Tx output power is below low alarm level 

113 

Rx Power High Alarm 

Set when received power exceeds high alarm level 

113 

Rx Power Low Alarm 

Set when received power is below low alarm level 

113 

5-0 

Reserved 

 

116 

Temp High Warning 

Set when internal temperature exceeds high warning level 

116 

Temp Low Warning 

Set when internal temperature is below low warning level 

116 

Vcc High Warning 

Set when internal supply voltage exceeds high warning level 

116 

Vcc Low Warning 

Set when internal supply voltage is below low warning level 

116 

Tx Bias High Warning 

Set when Tx Bias current exceeds high warning level 

116 

Tx Bias Low Warning 

Set when Tx Bias current is below low warning level 

116 

Tx Power High Warning 

Set when Tx output power exceeds high warning level 

116 

Tx Power Low Warning 

Set when Tx output power is below low warning level 

117 

Rx Power High Warning 

Set when received power exceeds high warning level 

117 

Rx Power Low Warning 

Set when received power is below low warning level 

117 

5-0 

Reserved 

 

Digital Diagnostic Monitor Accuracy

 

Parameter 

Typical Value 

Note 

Transceiver Temperature 

±

 3

 

Power Supply Voltage 

±

 3% 

TX Bias Current 

±

 10% 

 

TX Optical Power 

±

 1.5dB 

 

RX Optical Power 

±

 3dB 

Notes: 

Summary of Contents for Multi-Rate CWDM SFP Transceiver LCP-155 CWDM

Page 1: ...s up to 155 Mb s The LCP 155 CWDM series are support Fast Ethernet ATM and OC 3 SDH STM 1 standards The selectiveness of center wavelength has 1470 1490 1510 1530 1550 1570 1590 and 1610 nm The LCP 155 CWDM series are designed to be compliant with SFF 8472 SFP Multi source Agreement MSA with digital diagnostic monitoring functions Temperature VCC TX optical power TX laser bias current and RX recei...

Page 2: ...nsmitter Differential Input Voltage VDT 0 5 2 4 V 1 Transmitter Disable Input High VDISH 2 VCC V Transmitter Disable Input Low VDISL Vee 0 8 V Transmitter Fault Pull up Resistor RTX_FAULT 4 7 10 kΩ 2 Transmitter Fault Output High VTXFH 2 VCC V Transmitter Fault Output Low VTXFL Vee 0 8 V Receiver Receiver Differential Output Voltage VDR 0 35 2 V 3 Receiver LOS Load RRXLOS 4 7 10 kΩ 2 LOS Output Vo...

Page 3: ...57 5 1577 5 1597 5 1617 5 nm Spectral Width 20dB σ 1 nm Side mode Suppression Ratio SMSR 30 dB Optical Rise Fall Time tr tf 2 nsec 1 Relative Intensity Noise RIN 120 dB Hz Output Eye Compliant with ITU T G 957 Receiver VCC 3 3V 5 Data Rate 155Mb sec PRBS 223 1 NRZ Parameter Symbol Min Typ Max Unit Note Sensitivity Avg LCP 155D4RxxR LCP 155D4VxxR LCP 155D4UxxR PS 34 36 36 dBm 2 Input Optical Wavele...

Page 4: ...F 10uF 0 1uF 0 01uF 0 01uF 0 01uF 0 01uF 0 1uF 10uF RES1 RES1 100 Ohms RES1 RES1 RES1 10k Ohms 100 Ohms VCC Protocol Vcc SerDes IC Protocol IC PLD PAL Mod_def 2 Mod_def 1 Mod_def 0 3 3V 3 3V DELTA SFP Module Preamp Tx_Disable Quantizer Tx_Fault TD TD VeeT RD RD Rx_LOS VeeR Tx_Disable Tx_Fault Rx_LOS RES1 4 7k to 10k Ohms VccT VccR Laser Driver Depands on SerDes IC used EEPROM ...

Page 5: ...l ID interface 6 MOD DEF0 Module Definition 0 3 Note 3 Grounded in Module 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 Note 4 9 VeeR Receiver Ground 1 Note 5 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD Inv Received Data Out 3 Note 6 13 RD Received Data Out 3 Note 7 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 3 3 5 Note 7 16 Vcc...

Page 6: ...n In the low state the output will be pulled to 0 8V 5 VeeR and VeeT may be internally connected within the SFP module 6 RD These are the differential receiver outputs They are AC coupled 100Ω differential lines which should be terminated with 100Ω differential at the user SERDES The AC coupling is done inside the module and is thus not required on the host board The voltage swing on these lines w...

Page 7: ...5 LOS Assert Time t_loss_on 100 µsec 6 LOS Deassert Time t_loss_off 100 µsec 7 Serial ID Clock Rate f_serial_clock 100 kHz Notes 1 Time from rising edge of TX_DISABLE to when the optical output falls below 10 of nominal 2 Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90 of nominal 3 From power on or negation of TX_Fault using TX Disable 4 Time from fault to ...

Page 8: ...DELTA ELECTRONICS INC 8 Jun 2007 Rev 0F www deltaww com Package Outline Drawing ...

Page 9: ...about the module s present operating conditions 2 wire address 1010000 X A0h 2 wire address 1010001 X A2h 0 0 55 Alarm and Warning Thresholds 56 bytes 95 Serial ID Defined by SFP MSA 96 bytes 56 95 Cal Constants 40 bytes 96 96 119 Real Time Diagnostic Interface 24 bytes 127 Vender Specific 32 bytes 120 127 Vender Specific 128 128 247 User Writable EEPROM 120 bytes 255 Reserved in SFP MSA 128 bytes...

Page 10: ...1 Note 6 106 00 21 45 E 64 00 107 00 22 4C L 65 1A 108 00 23 54 T 66 00 109 00 24 41 A 67 00 110 00 25 20 68 SN Note 7 111 00 26 20 69 SN 112 00 27 20 70 SN 113 00 28 20 71 SN 114 00 29 20 72 SN 115 00 30 20 73 SN 116 00 31 20 74 SN 117 00 32 20 75 SN 118 00 33 20 76 SN 119 00 34 20 77 SN 120 00 35 20 78 SN 121 00 36 00 79 SN 122 00 37 00 80 SN 123 00 38 00 81 SN 124 00 39 00 82 SN 125 00 40 PN No...

Page 11: ...OP 8 mA 2 24 25 2 TX Power High Alarm P 3 26 27 2 TX Power Low Alarm P 3 28 29 2 TX Power High Warning P 2 30 31 2 TX Power Low Warning P 2 dBm 3 32 33 2 RX Power High Alarm P0 3 34 35 2 RX Power Low Alarm PS 2 36 37 2 RX Power High Warning P0 2 38 39 2 RX Power Low Warning PS dBm 4 40 45 16 Reversed 56 91 36 External Calibration Constants 92 94 3 Reversed 95 1 Checksum 5 96 97 2 Real Time Tempera...

Page 12: ...hen Tx output power exceeds high alarm level 112 0 Tx Power Low Alarm Set when Tx output power is below low alarm level 113 7 Rx Power High Alarm Set when received power exceeds high alarm level 113 6 Rx Power Low Alarm Set when received power is below low alarm level 113 5 0 Reserved 116 7 Temp High Warning Set when internal temperature exceeds high warning level 116 6 Temp Low Warning Set when i...

Page 13: ... Electromagnetic Interference EMC FCC Class B EN 55022 Class B CISPR 22 5 2 Immunity Radio Frequency Electromagnetic Field EN 61000 4 3 IEC 1000 4 3 5 3 Immunity Electrostatic Discharge to the Duplex SC Receptacle EN 61000 4 2 IEC 1000 4 2 IEC 801 2 5 4 Electrostatic Discharge to the Electrical Pins MIL STD 883C Method 3015 4 EIAJ 1988 3 2B Version 2 Machine model 5 1 Satisfied with electrical cha...

Page 14: ...e R RoHS Compliant X4 Temperature Blank 5 to 70 degree C H 10 to 85 degree C T 40 to 85 degree C Revision History Rev Date Contents 0A Jun 2006 First release 0B Aug 2006 Add 10 to 85 and 40 to 85 degree C P Ns in data sheet 0C Aug 2006 1 Update A2h design 2 Changed the wavelength range 0D Nov 2006 Add LCP 155D4UxxR series products in data sheet 0E Dec 2006 To change the supply current from 300mA t...

Reviews: