Delta Electronics H48SA12025 Datasheet Download Page 2

 

 

DS_H48SA12025_05052008 

 

 

 

TECHNICAL SPECIFICATIONS

 

(T

A

=25°C, airflow rate=300 LFM, V

in

=48Vdc, nominal Vout unless otherwise noted.)

 

PARAMETER 

NOTES and CONDITIONS 

H48SA12025 (Standard)

 

 

 

Min.

 

Typ.

 

Max.

 

Units

 

ABSOLUTE MAXIMUM RATINGS 

 

 

 

 

 

Input Voltage

 

 

 

 

 

 

Continuous

 

 

  

80 

Vdc 

Transient (100ms) 

100ms 

 

 

100 

Vdc 

Operating Device Temperature(Openframe)

 

Please refer to fig24. for  the measuring point 

-40 

 

122 

°C 

Operating Device Temperature(Heatspreader)

 

Please refer to fig25. for  the measuring point 

-40 

 

109 

°C 

Storage Temperature

 

 

-55 

 

125 

°C 

Input/Output Isolation Voltage 

 

 

 

2250 

Vdc 

INPUT CHARACTERISTICS 

 

 

 

 

 

Operating Input Voltage

 

 

36 

48 

75 

Vdc

 

Input Under-Voltage Lockout 

 

 

 

 

 

Turn-On Voltage Threshold 

 

32.5 

34 

35.5 

Vdc

 

Turn-Off Voltage Threshold 

 

30.5 32 33.5 

Vdc

 

Lockout Hysteresis Voltage 

 

Vdc 

Maximum Input Current 

Vin=36V, 100% Load

 

 

 

9.5 A 

No-Load Input Current 

 

 

170 

240 

mA 

Off Converter Input Current 

 

 

 

18 

mA 

Inrush Current(I

2

t) 

With 100uF external input cap 

 

 

A

2

Input Terminal Ripple Current 

RMS, With 100uF/0.1ohm input cap, 100% Load

 

 

0.42 

Input Reflected-Ripple Current 

Pk-Pk, thru 12µH inductor, 5Hz to 20MHz, 100% Load

 

 

mA 

Input Voltage Ripple Rejection 

120 Hz 

 

50 

 

dB 

OUTPUT CHARACTERISTICS 

 

 

 

 

 

Output Voltage Set Point 

Vin=48V, Io=Io.max, Tc=25

 

11.82 

12 

12.18 

Vdc 

Output Voltage Regulation 

 

 

 

 

 

Over Load 

Io=Io,min to Io,max 

 

±10 

 

mV 

Over Line 

Vin=36V to 75V 

 

±10 

 

mV 

Over Temperature 

Tc=-40

 to 100

 

 

±120 

 

mV 

Total Output Voltage Range 

over sample load, line and temperature 

11.64 

 

12.36 

Output Voltage Ripple and Noise 

5Hz to 20MHz bandwidth 

 

 

 

 

Peak-to-Peak 

100% Load, 1µF ceramic, 10µF tantalum 

 

60 

120 

mV 

RMS 

100%

 

Load, 1µF ceramic, 10µF tantalum 

 

30 

60 

mV 

Operating Output Current Range 

Full input range 

 

25 

Operating Output Power Range  

Full input range 

 

300 

Output DC Current Protection 

Full input range 

110 

 

150 

DYNAMIC CHARACTERISTICS 

 

 

 

 

 

Output Voltage Current Transient 

48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs

 

 

 

 

Positive Step Change in Output Current 

50% Io,max to 75% Io,max 

 

400 

 

mV 

Negative Step Change in Output Current 

75% Io,max to 50% Io,max 

 

400 

 

mV 

Settling Time (within 1% Vout nominal) 

 

 

400 

 

uS 

Turn-On Transient 

 

 

 

 

 

Start-Up Time, From On/Off Control 

 

12 

 

28 mS 

Start-Up Time, From Input 

 

12 

 

28 

mS 

Maximum Output Capacitance 

100% Resistor load; 5% overshoot of Vout at startup

 

 

10000 

µF 

EFFICIENCY 

 

 

 

 

 

100% Load 

Vin=48V 

 

93.2 

 

60% Load 

Vin=48V  

92.5 

 

ISOLATION CHARACTERISTICS 

 

 

 

 

 

Input to Output  

 

 

 

2250 

Vdc 

Isolation Resistance 

 

10 

 

 

M

 

Isolation Capacitance 

 

 

1500 

 

pF 

FEATURE CHARACTERISTICS 

 

 

 

 

 

Switching Frequency 

 

 

300 

 

kHz 

ON/OFF Control, Negative Remote On/Off logic 

 

 

 

 

 

Logic Low (Module On) 

Von/off  

-2 

 

1.2 

Logic High (Module Off) 

Von/off  

 

18 

ON/OFF Control, Positive Remote On/Off logic 

 

 

 

 

 

    Logic Low (Module Off) 

Von/off  

-2 

 

1.2 

    Logic High (Module On) 

Von/off  

 

18 

ON/OFF Current (for both remote on/off logic) 

Ion/off at Von/off=0.0V 

 

 

0.3 

mA 

ON/OFF Current (for both remote on/off logic) 

Ion/off at Von/off=3V 

10 

 

 

uA 

Leakage Current(for both remote on/off logic) 

Logic High, Von/off=15V 

 

 

100 

uA 

Output Voltage Trim Range 

Pout <= max rated power 

9.6 

 

13.2 

Output Voltage Remote Sense Range 

Pout <= max rated power 

 

 

10 

Output Over-Voltage Protection 

Over full input range; Over full temp range 

115 

 

140 

GENERAL SPECIFICATIONS 

 

 

 

 

 

MTBF

 

Io=80% of Io, max; Ta=25°C,airflow  rate=300 LFM

 

1.5 

 

M hours

Weight 

Open frame 

 

80 

 

grams 

Over-Temperature Shutdown(Openframe) 

Please refer to Fig 24. for  the measuring point 

 

127 

 

°C 

Over-Temperature Shutdown(Heatspreader) 

Please refer to Fig 25. for  the measuring point 

 

116 

 

°C 

 

 

 

Summary of Contents for H48SA12025

Page 1: ...The Delphi Series H48SA Half Brick 48V input single output isolated open frame DC DC converters are the latest offering from a world leader in power systems technology and manufacturing Delta Electro...

Page 2: ...mV Operating Output Current Range Full input range 0 25 A Operating Output Power Range Full input range 0 300 W Output DC Current Protection Full input range 110 150 DYNAMIC CHARACTERISTICS Output Vol...

Page 3: ...age at 25 C Vout 12V Figure 2 Power dissipation vs load current for minimum nominal and maximum input voltage at 25 C Vout 12V 60 65 70 75 80 85 90 95 5 10 15 20 25 OUTPUT CURRENT A EFFICIENCY 36Vin 7...

Page 4: ...ge for minimum nominal and maximum input voltage at 25 C Vout 13 2V Figure 6 Power dissipation vs output voltage for minimum nominal and maximum input voltage at 25 C Vout 13 2V 0 2 4 6 8 10 12 30 0 3...

Page 5: ...ESR 0 2 ohm 25oC 100KHz Cs 220uF Vin Vin is ic 100uF ESR 0 2 ohm 25oC 100KHz Cs 220uF Figure 11 Output voltage response to step change in load current 200mV div 1ms div 75 50 75 of Io max di dt 1A s L...

Page 6: ...STIVE LOAD Figure 15 Output voltage noise and ripple measurement test setup Figure 16 Output voltage ripple at nominal input voltage and rated load current 50mV div 2us div Load capacitance 1 F cerami...

Page 7: ...e power module meets SELV safety extra low voltage requirements If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc for the module s output to meet...

Page 8: ...o restarted Auto restart mode is default mode For latch mode the module will latch off once it shutdown The latch is reset by either cycling the input power or by toggling the on off signal for one se...

Page 9: ...th When using remote sense and trim the output voltage of the module is usually increased which increases the power output of the module with the same output current Care should be taken to ensure tha...

Page 10: ...ules are mounted The following figure shows the wind tunnel characterization setup The power module is mounted on a test PWB and is vertically positioned within the wind tunnel The space between the n...

Page 11: ...put current vs ambient temperature and air velocity Vin 48V Vout 12V Openframe Version Either Orientation H48SA12025 standard Output Current vs Ambient Temperature and Air Velocity Vin 48V Either Orie...

Page 12: ...SENSE TRIM SENSE Vout Positive input voltage Remote ON OFF Case pin Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Positive output volta...

Page 13: ...DS_H48SA12025_05052008 MECHANICAL DRAWING WITH HEATSPREADER 13...

Page 14: ...DCDC delta corp com Europe Phone 41 31 998 53 11 Fax 41 31 998 53 53 Email DCDC delta es com Asia the rest of world Telephone 886 3 4526107 ext 6220 Fax 886 3 4513485 Email DCDC delta com tw WARRANTY...