Delta Electronics E48SB12020 Datasheet Download Page 9

DS_E48SB12020_05222008 
 

 
 

 

THERMAL CONSIDERATIONS 

 
Thermal management is an important part of the system 
design. To ensure proper, reliable operation, sufficient 
cooling of the power module is needed over the entire 
temperature range of the module. Convection cooling is 
usually the dominant mode of heat transfer. 
 
Hence, the choice of equipment to characterize the 
thermal performance of the power module is a wind 
tunnel.

 

 

Thermal Testing Setup 

 

Delta’s DC/DC power modules are characterized in 
heated vertical wind tunnels that simulate the thermal 
environments encountered in most electronics 
equipment. This type of equipment commonly uses 
vertically mounted circuit cards in cabinet racks in which 
the power modules are mounted. 
 
The following figure shows the wind tunnel 
characterization setup. The power module is mounted 
on a test PWB and is vertically positioned within the 
wind tunnel. The space between the neighboring PWB 
and the top of the power module is constantly kept at 
6.35mm (0.25’’). 

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

12.7 (0.5”) 

MODULE 

AIR FLOW 

50.8 (2.0”) 

FACING PWB

PWB 

AIR VELOCITY
AND AMBIENT 

TEMPERATURE 

MEASURED BELOW 

THE MODULE

Figure 17: 

Wind tunnel test setup 

 

Thermal Derating 

 

Heat can be removed by increasing airflow over the 
module. To enhance system reliability, the power module 
should always be operated below the maximum 
operating temperature. If the temperature exceeds the 
maximum module temperature, reliability of the unit may 
be affected. 

 

THERMAL CURVES 

Figure 18:

 Temperature measurement location 

The allowed maximum hot spot temperature is defined at 128

 

E48SB12020(Standard)  Output Current vs. Ambient Temperature and Air Velocity

@Vin = 48V (Transverse Orientation)

0

2

4

6

8

10

12

14

16

18

20

22

20

25

30

35

40

45

50

55

60

65

70

75

80

85

Ambient Temperature (

)

Output Current(A)

Natural

Convection

100LFM

200LFM

300LFM

400LFM

500LFM

Figure 19:

Output current vs. ambient temperature and air 

velocity@Vin=48V (Transverse Orientation)

 

 

Summary of Contents for E48SB12020

Page 1: ...us Converter DC DC Power Modules 48Vin 12V 20A out Delta Electronics Inc a world leader in power systems technology and manufacturing has introduced the E48SB eighth brick sized 240W bus converter int...

Page 2: ...ak to Peak Full Load 1 F ceramic 10 F tantalum 80 100 mV RMS Full Load 1 F ceramic 10 F tantalum 25 40 mV Output current range when Vin below 44V 0 22 3 A Operating Output Power Range Output power ran...

Page 3: ...at 25 C Figure 2 Power loss vs load current for minimum nominal and maximum input voltage at 25 C 2 4 6 8 10 12 14 0 3 6 9 12 15 18 21 24 27 Output Current A Output Voltage V 38Vin 48Vin 55Vin 17 00...

Page 4: ...OFF input 2V div Figure 6 Turn on transient at zero load current 5 ms div Top Trace Vout 5V div Bottom Trace ON OFF input 2V div For Positive Remote On Off Logic Figure 7 Turn on transient at full ra...

Page 5: ...ltage response to step change in load current 50 75 50 of Io max di dt 1A s Load cap 10uF tantalum capacitor and 1 F ceramic capacitor Top Trace Vout 200mV div 200us div Bottom Trace Iout 10A div Scop...

Page 6: ...minal input voltage and rated load current 20 mA div 20us div Vo Vo 10u 1u Copper Strip SCOPE RESISTIVE LOAD Figure 14 Output voltage noise and ripple measurement test setup Figure 15 Output voltage r...

Page 7: ...pliance with CISPR 22 class B which is shown as below Vin 48V Io 20A average mode Soldering and Cleaning Considerations Post solder cleaning is usually the final board assembly process before the boar...

Page 8: ...on the module can be either negative or positive logic Negative logic turns the module on during logic low and off during logic high Positive logic turns the modules on during logic high and off durin...

Page 9: ...ace between the neighboring PWB and the top of the power module is constantly kept at 6 35mm 0 25 Note Wind Tunnel Test Setup Figure Dimensions are in millimeters and Inches 12 7 0 5 MODULE AIR FLOW 5...

Page 10: ...1 2 3 4 5 Vin ON OFF Vin Vout Vout Positive input voltage Remote ON OFF Negative input voltage Negative output voltage Positive output voltage Pin Specification Pins 1 3 1 0mm 0 040 diameter Pins 4 5...

Page 11: ...ng system above or contact your local sales office CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Phone 4...

Reviews: