background image

 

 

 

Warning

 

    Please read this instruction sheet carefully before use and follow the sheet to operate TAP-CN01//02/03 in order to 

prevent damages on the device or injuries to staff. 

    Switch off the power before wiring. 

    This instruction only provides introductory information on electrical specifications, functions, wiring, 

trouble-shooting and peripherals for TAP-CN01/02/03.   

    TAP-CN01/02/03 is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, 

humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the 
device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may 
occur. 

    In order not to damage it, only qualified professional staff familiar with the structure and operation of 

TAP-CN01/02/03 can install, operate, wire and repair it.   

    DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all 

the wiring again before switching on the power and DO NOT touch any terminal when the power is switched on. 

 Introduction

 

Thank you very much for choosing Delta TAP-CN01/02/03  distribution box.  TAP-CN01/02/03 is the distribution 
box for the connection of main cable and sub cable in DeviceNet or CANopen. TB1 and TB2 are for connecting 
main cables, and TB3 ~ TB5 are for connecting sub cables. TAP-CN01/02/03 formulates a termination 
resistance, which is switched by the setup switch. 

 

Nameplate Explanation

 

VX.XXXX

MADE IN XXXXXX

R T U D E N T 0 0 T 7 2 0 0 0 0 1

MADE IN XXXXXX

CN010000W7250001

Model name

Barcode, Serial No.

Version

 

 

Serial No. Explanation

 

CN0X000

W

0001

0

7 25

Production No.

Production week

Production year (2007)

Production plant (W: Wujiang  T: Taoyuan)

Version No.

Model name

 

 

Product Profile & Outline 

1

 

DeviceNet/CANopen main cable connector

 

2

 

DeviceNet/CANopen main cable connector

 

3

 

DeviceNet/CANopen sub cable connector

 

4

 

Termination resistance setup switch

 

5

 

121

 termination resistance

 

1

2

3

4

5

6

6 6 .5 0 [2 .62 ]

8

7

.0

0

[3

.4

3

]

 

Unit: mm

 

6

 

DIN rail

 

 

ENGLISH 

1

 

DeviceNet/CANopen main cable connector 

2

 

DeviceNet/CANopen main cable connector 

3

 

DeviceNet/CANopen sub cable connector 

4

 

DeviceNet/CANopen sub cable connector 

5

 

DeviceNet/CANopen sub cable connector 

6

 

Termination resistance setup switch 

7

 

121

 termination resistance 

1

2

3

4

5

6

7

8

96.50[ 3.80]

9

7

.0

0

[3

.4

3

]

 

Unit: mm

 

8

 

DIN rail 

 

1

 

DeviceNet/CANopen main cable connector

 

2

 

DeviceNet/CANopen main cable connector

 

3

 

DeviceNet/CANopen sub cable connector

 

4

 

DeviceNet/CANopen sub cable connector

 

5

 

DeviceNet/CANopen sub cable connector

 

6

 

Termination resistance setup switch

 

7

 

121

 termination resistance

 

5

6

7

8

1

2

3

4

66.50[ 2.62]

6

6

.5

0

[2

.6

2

]

 

Unit: mm

 

8

 

DIN rail

 

 Specifications 

 

Electrical Specifications 

DeviceNet 

Voltage: 11 ~ 25V DC (supplied by the power cable in the network) 

 

Environment 

Operation/Storage 

Operation: 0ºC ~ 55ºC (temperature), 50 ~ 95% (humidity), pollution degree 2 

Storage: -25ºC ~ 70ºC (temperature), 5 ~ 95% (humidity) 

 How to Install

 

 

Use efficient tool to peel the communication cable 
for approx. 30mm. DO NOT damage the shielded 
cable while peeling.

 

App rox. 3 0m m

 

 

Peel off the metallic shielded net and foil and you 
will see 2 power cables (in red and black), 2 signal 
cables (in blue and white) and 1 shielded cable.

 

Shielded cable

 

  Peel off the exterior metallic shielded net, foil and 

the plastic cover of the power cable and signal cable 
in proper length.

 

 

  Insert the peeled communication cables into the 

holes in the connector in correct order.

 

Black (V-)

Blue (CAN_L)

Shielded cable (CAN_SHLD)

Red (V+)

White (CAN_H)

 

  Tighten the screws on the connector by a slotted 

screwdriver, and fix the communication cables in 
the holes in the connector.

 

Screw by a slotted screwdriver.

 

  Use standard 35mm DIN rail.

 

  Mount TAP-CN01/CN02/CN03 onto the DIN rail. 

 

OF F

OF F

OF F

TAP-C N01

TAP-C N02

TAP -CN0 3

 

 

  Insert the connectors into TAP-CN01/CN02/CN03. 

Insert the connector into
TAP-CN01 terminal.

Insert the connector into
TAP-CN02 terminal.

Insert the connector into
TAP-CN03 terminal.

 

Notes:

 

1.

 

Use only wires specifically designed for DeviceNet/CANopen for wiring. 

2.

 

The terminal screws shall be tightened to 5.18 kg-cm (4.5 in-lbs). 

3.

 

DO NOT place the signal cable and power cable in the same wiring circuit. 

 

 Electrical Circuit 

TAP-CN01 

TAP-CN02 

T

B

1

T

B

2

T

h

ic

C

a

b

le

T

h

ic

C

a

b

le

V+

V+

H

H

S

S

L

L

V-

V-

V+

H

S

L

V-

1

2

1

¿

TB3

Thin Cable

 

TB1

TB2

TB5

TB3

TB4

Thick Cable

Thick Cable

Thin Cable

Thin Cable

V+

V+

V+

H

H

H

S

S

S

L

L

L

V-

V-

V-

V+

V+

H

H

S

S

L

L

V-

V-

1

2

1

¿

 

TAP-CN03 

T

B

1

T

B

2

T

h

ic

C

a

b

le

T

h

ic

C

a

b

le

V+

V+

H

H

S

S

L

L

V-

V-

1

2

1

¿

TB 3

TB4

TB5

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

8 76 5 4 3 2 1

Thin Cable

Thin Cable

Thin Cable

 

 Components

 

 

DeviceNet/CANopen Connector 

To connect with the  DeviceNet/CANopen network, use the connector enclosed with TAP-CN01/02/03 or  any 
connectors you can buy in the store for wiring. 

 

PIN 

Signal 

Description 

V- 

V- 

0V DC 

CAN_L 

Signal- 

SHIELD 

Shielded  cable 

CAN_H 

 

V+ 

V+ 

24V DC 

 

V-

L

S

H

V+

 

 

PIN 

Signal 

Description 

CAN_H 

 

CAN_L 

Signal- 

CAN_GND 

0V DC 

RESE_1 

Reserved 

RESE_2 

Reserved 

CAN_SHLD 

Shielded  cable 

CAN_GND 

0V DC 

CAN_V+ 

24V DC 

1

2

3

4

5

6

7

8

 

 

Termination Resistance Setup Switch

 

O N
O FF

 

The termination resistance switch is used for determining whether the resistance is valid. 

ON = valid; OFF = invalid. 

 

Termination Resistance

 

 

TAP-CN01/CN02/CN03 formulates a 121

 termination resistance. 

 Connection Example

 

Establishing a network through TAP-CN01/CN02/CN03: 

 

 

 

TAP-CN02

TAP-CN01

TAP-CN03

Main  cable

Main  cable

Main  cable

Sub cable

Sub cable

Sub cable

S

u

b

 c

a

b

le

S

u

b

 c

a

b

le

S

u

b

 c

a

b

le

 

  To install TAP-CN01/CN02/CN03 in the starting point or end of the network, you have to switch ON the 

termination resistance. To install TAP-CN01/CN02/CN03 in the middle of the network, you have to switch 
OFF the termination resistance.

 

  When using TAP-CN01/CN02/CN03 to establish a DeviceNet/CANopen network, the sub cable cannot be 

longer than 6m.

 

 

注意事項 

 

請務必在使用之前仔細閱讀本使用手冊,並按照本手冊指示進行操作,以免造成產品受損,或導致人員受傷。

 

 

實施配線,務必關閉電源。

 

 

本使用說明書僅提供電氣規格、功能規格、安裝配線、故障排除及周邊裝置部分說明。

 

 

本機為開放型

  (OPEN  TYPE) 

機殼,因此使用者使用本機時,必須安裝於具防塵、防潮及免於電擊

/

衝擊意外

的外殼配線箱內。另必須具備保護措施

  (

如:特殊的工具或鑰匙才可打開

,防止非維護人員操作或意外衝擊

本體,造成危險及損壞。請勿在上電時觸摸任何端子。

 

 

為避免損壞本產品,只有合格且熟悉本產品結構及操作的專業人員才可進行本產品的安裝、操作、配線及維
護。

 

 

交流輸入電源不可連接於輸入

/

輸出信號端,否則可能造成嚴重損壞。請在上電前再次確認電源配線,且請勿

在上電時觸摸任何端子。本體上的接地端子。

 

 

產品簡介

 

謝謝您使用台達

TAP-CN01/CN02/CN03

分接盒。

TAP-CN01/CN02/CN03

定義為

DeviceNet

CANopen

分接盒,

用於

DeviceNet

或者

CANopen

主幹線與分支線的連接,

TB1

TB2

用於連接主幹線,

TB3 ~ TB5

用於連接分支

線。

TAP-CN01/CN02/CN03

集成一個

121

歐姆的終端電阻,並通過

SW

開關來切換是否有效。

 

 

銘牌說明

銘牌說明

銘牌說明

銘牌說明

 

VX.XXXX

MADE IN XXXXXX

RT UDENT0 0T7 2 0 0 0 0 1

MADE IN XXXXXX

CN 010 000W 725 000 1

產品型號

管理條碼序號

版本

 

 

序號說明

序號說明

序號說明

序號說明

 

CN0X000

W

0001

0

7 25

製造序號
生產週次
生產年份(2007年)
製造工廠(W: 吳江廠  T:桃園廠)
版本序號
生產機種

 

 

產品外觀及各部介紹

產品外觀及各部介紹

產品外觀及各部介紹

產品外觀及各部介紹

 

1

 

DeviceNet/CANopen

主幹線通訊連接器

 

2

 

DeviceNet/CANopen

主幹線通訊連接器

 

3

 

DeviceNet/CANopen

分支線通訊連接器

 

4

 

終端電阻設置開關

 

5

 

121

Ω終端電阻

 

1

2

3

4

5

6

66. 50[2.62]

8

7

.0

0

[3

.4

3

]

 

尺寸單位:

mm 

6

 

DIN

軌槽

 

繁體中文

繁體中文

繁體中文

繁體中文    

1

  DeviceNet/CANopen

主幹線通訊連接器

 

2

  DeviceNet/CANopen

主幹線通訊連接器

 

3

  DeviceNet/CANopen

分支線通訊連接器

 

4

  DeviceNet/CANopen

分支線通訊連接器

 

5

  DeviceNet/CANopen

分支線通訊連接器

 

6

 

終端電阻設置開關

 

7

  121

Ω終端電阻

 

1

2

3

4

5

6

7

8

96.50[ 3.80]

9

7

.0

0

[3

.4

3

]

尺寸單位:

mm 

8

  DIN

軌槽

 

 

功能規格 

 

電氣規格

電氣規格

電氣規格

電氣規格

 

DeviceNet 

電壓規格:

11 ~ 25V DC

(由網路中的電源線提供)

 

 

環境規格

環境規格

環境規格

環境規格

 

操作

/

儲存環境

 

操作:

0ºC ~ 55ºC

(溫度)、

50 ~ 95%

(濕度)、污染等級

  2 

儲存:

-25ºC ~  70ºC

(溫度)、

5 ~ 95%

(濕度)

 

 

安裝說明

 

 

請使用專業工具將通訊電纜剝開大約

30mm

,在剝線過程

中注意不要損壞遮蔽線。

 

大約 30mm

 

 

剝開外層的金屬遮蔽網和鋁箔,你會看到

2

根電源線(紅

色和黑色)、

2

根信號線(藍色和白色)、

1

根遮蔽線。

 

遮蔽線

 

 

去除外層的金屬遮蔽網和鋁箔,然後剝去電源線以及信號
線的塑膠表皮,剝開的長度要適當。

 

 

1

 

DeviceNet/CANopen

主幹線通訊連接器

 

2

 

DeviceNet/CANopen

主幹線通訊連接器

 

3

 

DeviceNet/CANopen

分支線通訊連接器

 

4

 

DeviceNet/CANopen

分支線通訊連接器

 

5

 

DeviceNet/CANopen

分支線通訊連接器

 

6

 

終端電阻設置開關

 

7

 

121

Ω終端電阻

 

5

6

7

8

1

2

3

4

66.50[ 2.62]

6

6

.5

0

[2

.6

2

]

 

尺寸單位:

mm 

8

 

DIN

軌槽

 

Reviews: