The input source must be insulated from the ac 

mains by reinforced or double insulation. 

 

 

The input terminals of the module are not operator 

accessible. 

 

 

If the metal baseplate is grounded

one Vi pin and 

one Vo pin shall also be grounded. 

 

 

A SELV reliability test is conducted on the system 

where the module is used

in combination with the 

module, to ensure that under a single fault, 
hazardous voltage does not appear at the module’s 
output. 

 
When installed into a Class II equipment (without 
grounding), spacing consideration should be given to 
the end-use installation, as the spacing between the 
module and mounting surface have not been evaluated.

 

The power module has extra-low voltage (ELV) outputs 
when all inputs are ELV. 
 
This power module is not internally fused. To achieve 
optimum safety and system protection, an input line 
fuse is highly recommended. The safety agencies 
require a normal-blow fuse with 10A maximum rating to 
be installed in the ungrounded lead. A lower rated fuse 
can be used based on the maximum inrush transient 
energy and maximum input current. 

 

Soldering and Cleaning Considerations 

 
Post solder cleaning is usually the final board assembly 
process before the board or system undergoes 
electrical testing. Inadequate cleaning and/or drying 
may lower the reliability of a power module and severely 
affect the finished circuit board assembly test. Adequate 
cleaning and/or drying are especially important for 
un-encapsulated and/or open frame type power 
modules. For assistance on appropriate soldering and 
cleaning procedures, please contact Delta’s technical 
support team. 

DESIGN CONSIDERATIONS 

 

Input Source Impedance 

 
The impedance of the input source connecting to the 
DC/DC power modules will interact with the modules and 
affect the stability. A low ac-impedance input source is 
recommended. If the source inductance is more than a 
few 

µ

H, we advise adding a 10 to 100 

µ

F electrolytic 

capacitor (ESR < 0.7 

 at 100 kHz) mounted close to the 

input of the module to improve the stability.

 

 

Layout and EMC Considerations 

 
Delta’s DC/DC power modules are designed to operate 
in a wide variety of systems and applications. For design 
assistance with EMC compliance and related PWB 
layout issues, please contact Delta’s technical support 
team. An external input filter module is available for 
easier EMC compliance design. Application notes to 
assist designers in addressing these issues are pending 
to release. 

 

Safety Considerations 

 
The power module must be installed in compliance with 
the spacing and separation requirements of the 
end-user’s safety agency standard, i.e., UL60950, 
CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and 
IEC60950-1999, if the system in which the power module 
is to be used must meet safety agency requirements. 
 
Basic insulation based on 75 Vdc input is provided 
between the input and output of the module for the 
purpose of applying insulation requirements when the 
input to this DC-to-DC converter is identified as TNV-2 or 
SELV.    An additional evaluation is needed if the source 
is other than TNV-2 or SELV. 
 
When the input source is SELV circuit, the power module 
meets SELV (safety extra-low voltage) requirements. If 
the input source is a hazardous voltage which is greater 
than 60 Vdc and less than or equal to 75 Vdc, for the 
module’s output to meet SELV requirements, all of the 
following must be met:

 

 

DS_L36SA3R315_02142007 
 

 
 

Summary of Contents for Delphi L36SA

Page 1: ...chnology and manufacturing Delta Electronics Inc This L36SA series provides up to 50 watts of power or 15A of output current 3 3V in an industry standard 2 x 1 6 form factor and pinout The Delphi L36SA series operates from a wide 18 75V 4 1 input voltages With creative design technology and optimization of component placement these converters possess outstanding electrical and thermal performances...

Page 2: ...ut Current Range 0 15 A Output over current protection 110 150 DYNAMIC CHARACTERISTICS Output Voltage Current Transient 48V 10µF Tan 1µF Ceramic load cap 0 1A µs Positive Step Change in Output Current 50 Io max to 75 Io max 80 mV Negative Step Change in Output Current 75 Io max to 50 Io max 80 mV Settling Time within 1 Vout nominal 150 us Turn On Transient Start Up Time From On Off Control 20 ms S...

Page 3: ...ad current for minimum nominal and maximum input voltage at 25 C Figure 2 Power dissipation vs load current for minimum nominal and maximum input voltage at 25 C 0 0 3 0 6 0 9 1 2 1 5 1 8 2 1 2 4 2 7 3 3 3 16 21 26 31 36 41 46 51 56 61 66 71 INPUT VOLTAGE V INPUT CURRENT A Figure 3 Typical full load input characteristics at room temperature 75Vin 18Vin 24Vin 48Vin 24Vin 18Vin 48Vin 75Vin DS_L36SA3...

Page 4: ...ient at zero load current 5 ms div Vin 48V Top Trace Vout 1V div Bottom Trace ON OFF input 5V div For Positive Remote On Off Logic Figure 6 Turn on transient at full rated load current resistive load 5 ms div Vin 48V Top Trace Vout 1V div Bottom Trace ON OFF input 5V div Figure 7 Turn on transient at zero load current 5 ms div Vin 48V Top Trace Vout 1V div Bottom Trace ON OFF input 5V div 0 0 0 0 ...

Page 5: ... current 75 50 75 of Io max di dt 1A µs Load cap 330µF 35mΩ ESR solid electrolytic capacitor and 1µF ceramic capacitor Top Trace Vout 100mV div 200us div Bottom Trace I out 3 75A div Scope measurement should be made using a BNC cable length shorter than 20 inches Position the load between 51 mm to 76 mm 2 inches to 3 inches from the module Figure 10 Test set up diagram showing measurement points f...

Page 6: ...rce impedance and 33µF electrolytic capacitor 500 mA div 2us div Figure 12 Input reflected ripple current is through a 12µH source inductor at nominal input voltage and rated load current 20 mA div 2us div Strip Copper Vo Vo 10u 1u SCOPE RESISTIVE LOAD Figure 13 Output voltage noise and ripple measurement test setup 0 0 DS_L36SA3R315_02142007 6 ...

Page 7: ...t Io 10A 10 mV div 2us div Load capacitance 1µF ceramic capacitor and 10µF tantalum capacitor Bandwidth 20 MHz Scope measurements should be made using a BNC cable length shorter than 20 inches Position the load between 51 mm to 76 mm 2 inches to 3 inches from the module Figure 15 Output voltage vs load current showing typical current limit curves and converter shutdown points 0 DS_L36SA3R315_02142...

Page 8: ...support team DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC DC power modules will interact with the modules and affect the stability A low ac impedance input source is recommended If the source inductance is more than a few µH we advise adding a 10 to 100 µF electrolytic capacitor ESR 0 7 Ω at 100 kHz mounted close to the input of the module to ...

Page 9: ...ng a logic low and off during logic high Positive logic turns the modules on during logic high and off during logic low Remote on off can be controlled by an external switch between the on off terminal and the Vi terminal The switch can be an open collector or open drain For negative logic if the remote on off feature is not used please short the on off pin to Vi For positive logic if the remote o...

Page 10: ...uit configuration for trim up increase output voltage If the external resistor is connected between the TRIM and SENSE the output voltage set point increases Fig 19 The external resistor value required to obtain a percentage output voltage change is defined as Ω K up Rtrim 2 10 511 1 225 100 Vo 11 5 Ex When Trim up 10 5V 1 1 5 5V Ω K up Rtrim 168 2 10 10 511 10 1 225 10 100 5 11 5 The output volta...

Page 11: ...n the neighboring PWB and the top of the power module is constantly kept at 6 35mm 0 25 Note Wind Tunnel Test Setup Figure Dimensions are in millimeters and Inches 12 7 0 5 MODULE AIR FLOW 50 8 2 0 FACING PWB PWB AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE Figure 20 Wind tunnel test setup Thermal Derating Heat can be removed by increasing airflow over the module To enhance syste...

Page 12: ...IVE INPUT VOLTAGE 4 NC NOT CONNECTED 5 ON OFF REMOTE ON OFF 6 TRIM OUTPUT VOLTAGE TRIM 7 SENSE OPTION NEGATIVE OUTPUT VOLTAGE SENSE 8 VOUT NEGATIVE OUTPUT VOLTAGE 9 VOUT POSITVE OUTPUT VOLTAGE 10 SENSE OPTION POSITVE OUTPUT VOLTAGE SENSE 11 NC NOT CONNECTED ALL PINS ARE COPPER WITH TIN PLATING DS_L36SA3R315_02142007 12 ...

Page 13: ...t your local sales CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Telephone 41 31 998 53 11 Fax 41 31 998 53 53 Email DCDC delta es tw Asia the rest of world Telephone 886 3 4526107 x6220 Fax 886 3 4513485 Email DCDC delta com tw WARRANTY Delta offers a two 2 year limited warranty Complete warranty infor...

Reviews: