The input source must be insulated from the ac 

mains by reinforced or double insulation. 

 

 

The input terminals of the module are not operator 

accessible. 

 

 

If the metal baseplate is grounded

one Vi pin and 

one Vo pin shall also be grounded. 

 

 

A SELV reliability test is conducted on the system 

where the module is used

in combination with the 

module, to ensure that under a single fault, 
hazardous voltage does not appear at the module’s 
output. 

 
When installed into a Class II equipment (without 
grounding), spacing consideration should be given to 
the end-use installation, as the spacing between the 
module and mounting surface have not been evaluated.

 

The power module has extra-low voltage (ELV) outputs 
when all inputs are ELV. 
 
This power module is not internally fused. To achieve 
optimum safety and system protection, an input line fuse 
is highly recommended. The safety agencies require a 
normal-blow fuse with 20A maximum rating to be 
installed in the ungrounded lead. A lower rated fuse can 
be used based on the maximum inrush transient energy 
and maximum input current. 

 
 

Soldering and Cleaning Considerations 

 
Post solder cleaning is usually the final board assembly 
process before the board or system undergoes electrical 
testing. Inadequate cleaning and/or drying may lower the 
reliability of a power module and severely affect the 
finished circuit board assembly test. Adequate cleaning 
and/or drying is especially important for un-encapsulated 
and/or open frame type power modules. For assistance 
on appropriate soldering and cleaning procedures, 
please contact Delta’s technical support team. 

DESIGN CONSIDERATIONS 

 

Input Source Impedance 

 
The impedance of the input source connecting to the 
DC/DC power modules will interact with the modules 
and affect the stability. A low ac-impedance input source 
is recommended. If the source inductance is more than 
a few 

µ

H, we advise adding a 10 to 100 

µ

F electrolytic 

capacitor (ESR < 0.7 

 at 100 kHz) mounted close to 

the input of the module to improve the stability.

 

 

Layout and EMC Considerations 

 
Delta’s DC/DC power modules are designed to operate 
in a wide variety of systems and applications. For design 
assistance with EMC compliance and related PWB 
layout issues, please contact Delta’s technical support 
team. An external input filter module is available for 
easier EMC compliance design.  Application notes to 
assist designers in addressing these issues are pending 
release.

 

 

Safety Considerations 

 
The power module must be installed in compliance with 
the spacing and separation requirements of the 
end-user’s safety agency standard, i.e., UL60950, 
CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and 
IEC60950-1999, if the system in which the power 
module is to be used must meet safety agency 
requirements. 
 
Basic insulation based on 75 Vdc input is provided 
between the input and output of the module for the 
purpose of applying insulation requirements when the 
input to this DC-to-DC converter is identified as TNV-2 
or SELV.  An additional evaluation is needed if the 
source is other than TNV-2 or SELV. 
 
When the input source is SELV circuit, the power module 
meets SELV (safety extra-low voltage) requirements. If 
the input source is a hazardous voltage which is greater 
than 60 Vdc and less than or equal to 75 Vdc, for the 
module’s output to meet SELV requirements, all of the 
following must be met:

 

Summary of Contents for Delphi H48SV

Page 1: ...put output voltage current and temperature conditions The Delphi Series converters meet all safety requirements with basic insulation OPTIONS Positive Remote On Off logic Short pin lengths available A...

Page 2: ...A Output DC Current Limit Inception Output Voltage 10 Low 110 150 DYNAMIC CHARACTERISTICS Output Voltage Current Transient 48V 10 F Tan 1 F Ceramic load cap 0 1A s Positive Step Change in Output Curre...

Page 3: ...9 0 10 0 11 0 12 0 13 0 14 0 2 5 5 7 5 10 12 5 15 17 5 20 OUTPUT CURRENT A POWER DISSIPATION W 36Vin 48Vin 75Vin Figure 1 Efficiency vs load current for minimum nominal and maximum input voltage at 2...

Page 4: ...re 5 Turn on transient at zero load current 2 ms div Vin 48V Top Trace Vout 2V div Bottom Trace ON OFF input 5V div For Positive Remote On Off Logic Figure 6 Turn on transient at full rated load curre...

Page 5: ...p change in load current 75 50 75 of Io max di dt 2 5A s Load cap 470 F 35m ESR solid electrolytic capacitor and 1 F ceramic capacitor Top Trace Vout 100mV div Bottom Trace Iout 5A div Scope measureme...

Page 6: ...voltage with 12 H source impedance and 33 F electrolytic capacitor 200 mA div Figure 12 Input reflected ripple current is through a 12 H source inductor at nominal input voltage and rated load current...

Page 7: ...nd rated load current Io 20A 20 mV div Load capacitance 1 F ceramic capacitor and 10 F tantalum capacitor Bandwidth 20 MHz See Figure 12 Scope measurement should be made using a BNC cable length short...

Page 8: ...25 35 45 55 65 75 85 95 105 Ambient Temperature Output Current A Natural Convection 100LFM 200LFM 300LFM 400LFM 500LFM 600LFM H48SV05020 Standard Output Current vs Ambient Temperature and Air Velocit...

Page 9: ...ta s technical support team DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC DC power modules will interact with the modules and affect the stability...

Page 10: ...a logic high Positive logic turns the modules on during a logic high and off during a logic low Remote on off can be controlled by an external switch between the on off terminal and the Vi terminal Th...

Page 11: ...reases the power output of the module with the same output current Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power FEATURES DESCR...

Page 12: ...n which the power modules are mounted The following figure shows the wind tunnel characterization setup The power module is mounted on a test PWB and is vertically positioned within the wind tunnel Th...

Page 13: ...egative input voltage Case Ground Remote ON OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage Pin Specification...

Page 14: ...c and pin length please refer to part numbering system above or contact your local sales CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Em...

Reviews: