Delta Electronics Delphi F48SA Datasheet Download Page 8

DESIGN CONSIDERATIONS 

 

Input Source Impedance 

 
The impedance of the input source connecting to the 
DC/DC power modules will interact with the modules 
and affect the stability. A low ac-impedance input source 
is recommended. If the source inductance is more than 
a few 

μ

H, we advise adding a 220 to 470 

μ

F electrolytic 

capacitor (ESR < 0.1 

 at 100 kHz) mounted close to 

the input of the module to improve the stability.

 

 

Layout and EMC Considerations 

 
Delta’s DC/DC power modules are designed to operate 
in a wide variety of systems and applications. For design 
assistance with EMC compliance and related PWB 
layout issues, please contact Delta’s technical support 
team. An external input filter module is available for 
easier EMC compliance design.  Application notes to 
assist designers in addressing these issues are pending 
release. 
 

Safety Considerations 

 
The power module must be installed in compliance with 
the spacing and separation requirements of the 
end-user’s safety agency standard, i.e., UL60950, 
CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and 
IEC60950-1999, if the system in which the power 
module is to be used must meet safety agency 
requirements. 
 
Basic insulation based on 75 Vdc input is provided 
between the input and output of the module for the 
purpose of applying insulation requirements when the 
input to this DC-to-DC converter is identified as TNV-2 
or SELV.  An additional evaluation is needed if the 
source is other than TNV-2 or SELV. 
 
When the input source is SELV, the power module meets 
SELV (safety extra-low voltage) requirements. If the 
input source is a hazardous voltage which is greater than 
60 Vdc and less than or equal to 75 Vdc, for the module’s 
output to meet SELV requirements, all of the following 
must be met: 

 

 
 
 
 

 

The input source must be insulated from the ac 

mains by reinforced or double insulation. 

 

 

The input terminals of the module are not operator 

accessible. 

 

 

If the metal baseplate is grounded

one Vi pin and 

one Vo pin shall also be grounded. 

 

 

A SELV reliability test is conducted on the system 

where the module is used

in combination with the 

module, to ensure that under a single fault, 
hazardous voltage does not appear at the module’s 
output. 

 
 
When installed into a Class II equipment (without 
grounding), spacing consideration should be given to 
the end-use installation, as the spacing between the 
module and mounting surface have not been evaluated.

 

The power module has extra-low voltage (ELV) outputs 
when all inputs are ELV. 
 
This power module is not internally fused. To achieve 
optimum safety and system protection, an input line fuse 
is highly recommended. The safety agencies require a 
normal-blow fuse with 20A maximum rating to be 
installed in the ungrounded lead. A lower rated fuse can 
be used based on the maximum inrush transient energy 
and maximum input current. 

 

Soldering and Cleaning Considerations 

 
Post solder cleaning is usually the final board assembly 
process before the board or system undergoes electrical 
testing. Inadequate cleaning and/or drying may lower the 
reliability of a power module and severely affect the 
finished circuit board assembly test. Adequate cleaning 
and/or drying is especially important for un-encapsulated 
and/or open frame type power modules. For assistance 
on appropriate soldering and cleaning procedures, 
please contact Delta’s technical support team. 

 

DS_F48SA28025_12072007 

 
 

Summary of Contents for Delphi F48SA

Page 1: ...isolated DC DC converter is the latest offering from a world leader in power systems technology and manufacturing Delta Electronics Inc The Delphi F48SA series provides up to 700 watts of power or up...

Page 2: ...Noise 5Hz to 20MHz bandwidth Peak to Peak Full Load 1 F ceramic 10 F Low ESR cap 200 mV RMS Full Load 1 F ceramic 10 F Low ESR cap 65 mV Operating Output Current Range 2 25 A Output DC Current Limit...

Page 3: ...rrent for minimum nominal and maximum input voltage at 25 C 70 75 80 85 90 95 0 5 10 15 20 25 30 OUTPUT CURRENT A EFFICIENCY 36Vin 48Vin 75Vin Figure 2 Power dissipation vs load current for minimum no...

Page 4: ...urn on transient at minimum load current CH3 Vout 5V div CH1 ON OFF input 5V div For Positive Remote On Off Logic Figure 5 Turn on transient at full rated load current resistive load 10ms div Top Trac...

Page 5: ...nge in load current 50 75 of Io max di dt 1A s Load cap 470 F aluminum 10uF Low ESR capacitor and 1 F ceramic capacitor Top Trace Vout 200mV div Bottom Trace Iout 10A div Scope measurement should be m...

Page 6: ...th 15 H source impedance and 220 F electrolytic capacitor 1A div Figure 11 Input reflected ripple current is through a 15 H source inductor at nominal input voltage and rated load current 10 mA div Fi...

Page 7: ...1 F ceramic capacitor and 10 Flow ESR capacitor Bandwidth 20 MHz Scope measurement should be made using a BNC cable length shorter than 20 inches Position the load between 51 mm to 76 mm 2 inches to 3...

Page 8: ...ous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc for the module s output to meet SELV requirements all of the following must be met The input source must be insulated from the...

Page 9: ...the module will shut down again This restart trial will continue until the temperature is within specification Remote On Off On Off Vin Vin On Off Input side on off control On Off Aux Sense On Off Ou...

Page 10: ...uit configuration for trim up increase output voltage If the external resistor is connected between the TRIM and SENSE the output voltage set point increases Fig 19 The external resistor value require...

Page 11: ...l environments encountered in most electronics equipment This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted The following fig...

Page 12: ...out Vout gative input volt sitive input v Po oltage Negative Remote ON O Positive Remote ON OFF Positive output voltage Positive output voltage Positive output voltage Negative output voltage Negative...

Page 13: ...335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Phone 41 31 998 53 11 Fax 41 31 998 53 53 Email DCDC delta es com Asia the rest of world Telephone 886 3 4526107 ext...

Reviews: