Preliminary DS_NE12S20A_07272007

 

7

Output Voltage Programming 

 

The output voltage of the NE series is trimmable by 
connecting an external resistor between the trim pin and 
output ground as shown Figure 21 and the typical trim 
resistor values are shown in Table 1.   
 

FEATURES DESCRIPTIONS (CON.) 

 

The ENABLE input can be driven in a variety of ways as
shown in Figures 19 and 20. If the ENABLE signal comes
from the primary side of the circuit, the ENABLE can be
driven through either a bipolar signal transistor (Figure
18).If the enable signal comes from the secondary side, 
then an opto-coupler or other isolation devices must be
used to bring the signal across the voltage isolation
(please see Figure 19). 

 

ND6A/10A

 

Vout

 

Ground

 

Trim

 

Enable

 

Ground

 

Vin

 

 

Figure 19: Enable Input drive circuit for NE series 

 

Ground

 

Ground

 

 

 

ND 6A/10A

 

 

 

Vin

 

Vout

 

 

 

 

 

Trim

 

 

 

Enable

 

 

 

 

 

 

Figure 20: Enable input drive circuit example with isolation. 

 
Input Under-Voltage Lockout 

 
The input under-voltage lockout prevents the converter 
from being damaged while operating when the input
voltage is too low. The lockout occurs between 3.3V to 
4.3V. 
 

Over-Current and Short-Circuit Protection 

 
The NE series modules have non-latching over-current 
and short-circuit protection circuitry. When over current
condition occurs, the module goes into the non-latching 
hiccup mode. When the over-current condition is
removed, the module will resume normal operation. 
 
An over current condition is detected by measuring the
voltage drop across the MOSFETs. The voltage drop
across the MOSFET is also a function of the MOSFET’s
Rds(on). Rds(on) is affected by temperature, therefore
ambient temperature will affect the current limit inception 
point.  
 
The detection of the Rds(on) of    MOSFETs also acts as
an over temperature protection since high temperature
will cause the Rds(on) of the MOSFETs to increase,
eventually triggering over-current protection. 
 

 

Vin 

Vout 

Enable

Ground 

Ground 

Trim 

ND 6A/10A 

Rs 

 

 
Figure 21: 
Trimming Output Voltage 

 
 
The NE20 module has a trim range of 0.59V to 5.0V. 
The trim resistor equation for the NE20A is: 

591

.

0

1182

)

(

=

Vout

Rs

 

 
Vout is the output voltage setpoint 
Rs is the resistance between Trim and Ground 
Rs values should not be less than

 

240

 

 

Output Voltage 

Rs (

0.59V 

open 

+1 V 

2.4k 

+1.5 V 

1.3K 

+2.5 V 

619 

+3.3 V 

436 

+5.0V 

268 

Table 1: Typical trim resistor values 

 

 
 

NE20A 

NE20A

NE20A

 

Summary of Contents for 0.59V~5.1Vout

Page 1: ...fficiency and high density point of load solution With creative design technology and optimization of component placement these converters possess outstanding electrical and thermal performance as well as extremely high reliability under highly stressful operating conditions OPTIONS Vertical or horizontal versions APPLICATIONS DataCom Distributed power architectures Servers and workstations LAN WA...

Page 2: ...ature regulation and set point 2 0 2 0 Vo Output Voltage Ripple and Noise 5Hz to 20MHz bandwidth Peak to Peak Full Load 10uF Tan cap 12Vin 5Vo 20 mV RMS Full Load 10uF Tan cap 12Vin 5Vo 5 mV Output Current Range 0 20 A Output Voltage Under shoot at Power Off Vin 12V Turn OFF 100 mV Output short circuit current RMS value Continuous 3 6 A Output DC Current Limit Inception Hiccup mode 110 200 Iomax D...

Page 3: ...5 1 2 4 6 8 10 12 14 16 18 20 Output current A Efficiency 55 60 65 70 75 80 85 90 95 1 2 4 6 8 10 12 14 16 18 20 Output current A Efficiency Figure 3 Converter efficiency vs output current 1 5V output voltage 12V input Figure 4 Converter efficiency vs output current 2 5V output voltage 12V input 55 60 65 70 75 80 85 90 95 1 2 4 6 8 10 12 14 16 18 20 Output current A Efficiency 55 60 65 70 75 80 85...

Page 4: ...ipple noise at 12Vin 0 59V 20A out Figure 8 Output ripple noise at 12Vin 0 9V 20A out Figure 9 Output ripple noise at 12Vin 1 5V 20A out Figure 10 Output ripple noise at 12Vin 2 5V 20A out Figure 11 Output ripple noise at 12Vin 3 3V 20A out Figure 12 Output ripple noise at 12Vin 5 0V 20A out ...

Page 5: ...t Figure 14 Turn on delay time Remote On Off 2 5V 20A out Ch1 Enable Ch4 Vout Figure 15 Turn on delay time at 12Vin 3 3V 20A out Ch1 Vin Ch4 Vout Figure 16 Turn on delay time at Remote On Off 5 0V 20A out Ch1 Enable Ch4 Vout Figure 17 Typical transient response to step load change at 5A µS from 75 100 load at 12Vin 2 5V out 0 0 0 0 0 0 0 0 ...

Page 6: ...n the input line for safety The output voltage set point and the output current in the application could define the amperage rating of the fuse FEATURES DESCRIPTIONS Enable On Off The ENABLE on off input allows external circuitry to put the NE converter into a low power dissipation sleep mode Positive ENABLE is available as standard With the active high function the output is guaranteed to turn on...

Page 7: ...t occurs between 3 3V to 4 3V Over Current and Short Circuit Protection The NE series modules have non latching over current and short circuit protection circuitry When over current condition occurs the module goes into the non latching hiccup mode When the over current condition is removed the module will resume normal operation An over current condition is detected by measuring the voltage drop ...

Page 8: ...re 22 shows the circuit configuration for output voltage margining adjustment Vt Voltage Margining Adjustment FEATURES DESCRIPTIONS CON Output Capacitance There is internal output capacitor on the NE series modules Hence no external output capacitor is required for stable operation Reflected Ripple Current and Output Ripple and Noise Measurement The measurement set up outlined in Figure 23 has bee...

Page 9: ...5 60 65 70 75 80 85 Natural Convection 100LFM 200LFM Ambient Temperature Output Current A 500LFM 400LFM 600LFM 300LFM Thermal Testing Setup Delta s DC DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the p...

Page 10: ...rature and Air Velocity Vin 12V Vout 0 9V Through PWB Orientation 0 2 4 6 8 10 12 14 16 18 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Natural Convection 100LFM 200LFM Ambient Temperature Output Current A 500LFM 400LFM 300LFM Figure 29 Output current vs ambient temperature and air velocity Vin 12V Vout 0 9V Through PWB Orientation NE12S0A0V20 standard Output Current vs Ambient Temperature and Air Ve...

Page 11: ...Preliminary DS_NE12S20A_07272007 11 VERTICAL HORIZONTAL MECHANICAL DRAWING ...

Page 12: ... dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Telephone 41 31 998 53 11 Fax 41 31 998 53 53 Email DCDC delta es tw Asia the rest of world Telephone 886 3 4526107 ext 6220 Fax 886 3 4513485 Email DCDC delta com tw WARRANTY Delta offers a two 2 year limited warranty Complete warranty information is listed on our web site or is a...

Reviews: