background image

INFO

APPLICATION

Presentation

Installation

Tydom Pro

 must be installed on a DIN rail, either within a 

consumer unit, or in a VDI cabinet.

The equipment must be installed by a suitably qualified person.

Tydom Pro

 must be protected by a 

2A circuit breaker, 

which will also serve as a power switch.

Avoid proximity with power controls

(of the type used for domestic hot water contactors)

 Disconnect your installation’s 230V power supply.

Connect your Tydom Pro 

:

 connect the Ethernet cable (

B

). 

 then, connect the mains power line.

The 230 V power line must be stripped back to a length of 8 mm.

 To do so, you can make use 

of the design of the casing

 as shown below.  

Restore the power to the installation

.

Download the Tydom app

.

 -  Log in to either the Google Play or App Store, depending on your 

device.

 - Search for and download the free «Tydom» app. 

Activate the Wi-Fi

 connection on your smartphone or tablet

, and connect to the same local network as your Tydom Pro.

Configure the Tydom app.

 - Note the last 6 characters of your Tydom Home’s MAC address (stated 
on the front).
 - Log in to the app and follow the instructions.

Remote antenna

Some installation cases will require the use of a remote antenna (available as 

an accessory)

The radio range can be adjusted based on the installation conditions.

This is advised, for example, in the case of installation in a metallic cabinet or in proximity to a metallic mass.

2

8 mm

Ø 0,75-1,5 mm²

Technical specifications

230V, 50/60 Hz power supply 

Class II insulati on

X3D transmission frequency: 868.7 MHz to 879.2 MHz

Maximum wireless power < 10mW - Category 2 receiver

Zigbee transmission frequency: 2.4 GHz to 2.4835 GHz

 Maximum consumpti on (without USB connecti on): 1,1 W

-20°C / +70°C

-10°C / +40°C

IP

IP 30

4-module unit, height = 53 mm

Installati on in an environment with normal polluti on levels

Help

LED

System status

Flashing white

System accessible locally and 

remotely, user connected

Steady white

System accessible locally and 

remotely

Flashing orange

System accessible locally, user 

connected

Steady Orange

System accessible locally

Steady Red

No IP address allocated

5 red flashes

Thermal safety mechanism. 

Leave a clear space around the 

Tydom Pro in the event that it 

starts to heat up.

Advanced functions 

Below are the functions accessible depending on 

how long the button on the back of your Tydom 

Home is pressed

.

A

  

 Secure connection and viewing connection status

Briefly press the button. LED displays for 10 seconds.

Flashing yellow

Static IP mode

Flashing blue

DHCP mode

Flashing blue (3x)

DHCP in progress Check the DHCP 

activation on the router

Flashing red

No network connection Check 

the Ethernet link

B

  

Change from static IP to DHCP

Press the button for 3 seconds until the pink LED flashes 

slowly. Release.

C

 Reset to factory settings 

Press the button for 30 seconds until the LED stops 

flashing. Release.

System status

- DHCP mode

- Clear product associations

3’’

>

15’’

>

30’’

>

B

A

C

Static IP -> DHCP

RESET

xxxxxx

www.deltadore.com

Smart home hub

Tydom Pro

10/21

A

B

C

xxxxxx

D

E

F

H

I

G

xxxxxx

N

N

N

L

2A

ON

Box Internet

2A

xxxxxx

xxxxxx

N

L

N

N

2A

OFF

xxxxxx

The connection quality of the product may be affected by 

different modifications of the IP architecture on which it 

operates.

These modifications can be, but are not limited to, a change 

of hardware, a software update or configuration, work 

conducted on your operator’s equipment or any other 

multimedia equipment such as tablets, smartphones, etc.

IOS is a Cisco trademark or registered trademark in the 

United States and in other countries, and is used under 

licence. Android

TM

 and Google Play are Google LLC 

registered trademarks.

Wi-Fi

TM

 is a trademark registered by Wi-Fi Alliance.

Because of changes in standards and equipment,

the characteristics given in the text and the

illustrations in this document are not binding

unless confirmed.

Description

D. 230 V power supply terminal
E. Ethernet port

F. Configuration/Information/MAC address button
G. System status light

H. Remote antenna connection (optional)
I . USB port connection (optional)

Box contents

A. Tydom Pro

B. Ethernet cable

C. Important Product Information

Reserved functionality

Reviews: