Nothing is displayed on the room unit screen.
There is no power supply. 

Check the circuit breaker.

Pb — is displayed on the screen.
Problem with the connection on a Pilot Wire output. 

Contact our technical department.

The i symbol flashes.
A fault is detected on the installation. 

Press the button to view the fault(s).

The device displays: dEF and a number
There is a fault with the unit which requires a 
return to our after-sales service. 

Contact our technical department.

Troubleshooting

>5s

>5s

1

2

3

3

4

4

EXIT

5

3

4

0

23

0

59

1

2

1

7

2

0

>5s

1

0

1

2

3

4

5

6

7

8

Choix du pas de 

programmation

pas d'1 heure

pas de 30 minutes

pas de 15 minutes

Choix du type de  

programmation

Hebdomadaire

Journalière

2

0

>5s

1

0

1

2

3

4

5

6

7

8

Correction de

la température

mesurée.

De -5°C à + 5°C

Autorisation

de modification 

pour l'utilisateur

Modification autorisée du programme 

Modification non autorisée du programme

2 zones display is only available on 
DRIVER 620.  
If you want to exit configuration, turn the 
selector selector dial to the right.

Time setting

 

Basic configurations (menu 1)

 

Advanced configurations (menu 2)

 

Reset

Init

Menu 1

Init

Menu 2

Press 

> 5s

Appui 

> 5s

Press 

> 5s

The first time you activate the 
unit, you must set the clock.
Turn the selector dial to 

.

The days flash.

Press + or - to set the day, then 
OK to confirm and
go to the next setting.
Repeat these steps for the 
other menus.
To exit the “time setting” mode, 
turn the selector
selector dial.

To enter the configuration menus, turn the selector dial to 

, then press and hold the 

i

 button for 5 seconds. The 

unit will propose 2 configurations to choose.  
After each menu has been configured, the unit returns to the choice of menus.

Press button 2.
To modify the various settings, press the 
+ or - buttons, then press the OK button to 
validate and go to the next setting.

Press button 1.
To modify the various settings, press the 
+ or - buttons, then press the OK button to 
validate and go to the next setting.

If there is a difference between the actual
temperature (taken with a thermometer) and the
temperature measured and displayed by the unit,
function 2-02 can be used to compensate for the
difference by changing the way the sensor takes
measurements.

Example : If the temperature displayed by the unit is 
19°C and the temperature measured is 20°C, add 
1°C to the display and confirm by pressing OK.

The factory settings may be restored for each of the menus.
Turn the selector dial to 

, then press and hold the 

i

 button for 5 seconds.

Repeat these steps for the other menus.
To exit the mode, turn the knob to another mode.

Programming type
selection

Modification
authorization for
the user

Correcting the
temperature
measured.

Daily

Weekly

Program modification authorized

Program modification unauthorized

Correction possible from -5°C to + 5°C in 
increments of 0.1°C.
Press the + or – buttons to modify,
and press the OK button to confirm.

1-hour increments

30-minute increments

15-minute increments

Choice of 
programming
increments

Summary of Contents for DRIVER 610

Page 1: ...mpt to repair the unit yourself an after sales service is available Check that the fastenings are suited to the surface to which the unit will be attached plasterboard brick etc The diagrams provided...

Page 2: ...ation 1 or 2 pilot wires output 0 1A 230V Clock backup in the event of a blackout 2 hours per capacitor Dimensions WxHxD 80 x 103 x 16 mm Protection index IP 30 Installation in an environment with nor...

Page 3: ...the casing Unscrew the terminal box cover and lift it up as high as it will go to block it then position the base on the wall running the wires out through the hole in the cover Secure the base using...

Page 4: ...ER 620 Terminal 3 Convectors zone 1 Convectors zone 1 Terminal 4 Non Connected Convectors zone 2 N L N L Non connected Zone 1 Pilot Wire Convectors Zone 2 Pilot Wire Convectors Zone 1 Pilot Wire Conve...

Page 5: ...a sortie choisie Exemple test de la sortie 2 Output 2 test underway Repeat the operations for zone 1 Check the incorrect connections To exit test mode press the init button Checking the pilot wire con...

Page 6: ...u activate the unit you must set the clock Turn the selector dial to The days flash Press or to set the day then OK to confirm and go to the next setting Repeat these steps for the other menus To exit...

Page 7: ...ions menu 1 To enter the configuration menus turn the selector dial to then press and hold the i button for 5 seconds The unit will propose 2 configurations to choose After each menu has been configur...

Page 8: ...temperature taken with a thermometer and the temperature measured and displayed by the unit function 2 02 can be used to compensate for the difference by changing the way the sensor takes measurement...

Page 9: ...t Menu 2 Press 5s Press 5s The factory settings may be restored for each of the menus Turn the selector dial to then press and hold the i button for 5 seconds Repeat these steps for the other menus To...

Page 10: ...the connection on a Pilot Wire output Contact our technical department The i symbol flashes A fault is detected on the installation Press the button to view the fault s The device displays dEF and a...

Reviews: