Because of changes in standards and equipment, the characteristics given in 

the text and the illustrations of this document are not binding unless confirmed 

by our services.

• Carefully read these instructions prior to installation.
• The unit must be installed in compliance with
current standards.
• Always switch off the mains before installing or
servicing the unit.
• Do not attempt to repair the unit yourself;
an after-sales service is available.
• Check that the fastenings are suited to the surface to 
which the unit will be attached (plasterboard, brick, etc.).
• The diagrams provided are simplified for greater
clarity. Protections and other accessories required
by standards are not illustrated.
Standard NF C15-100 and good practice must be com-
plied with. Connected or nearby units must not generate 
excessive interference (directive 2004/108/EC).

1. Technical characteristics

3. Connection

• 230 V, 50 Hz power supply, ±10%

• Consumption: 2 VA

• Class II insulation

• 1 or 2 pilot wires output 0.1A / 230V

• Clock backup in the event of a blackout:

2 hours (per capacitor)

• Dimensions: WxHxD = 80 x 103 x 16 mm

• Protection index: IP 30

• Installation in an environment with normal pollution

levels

• Storage temperature: -10°C to +70°C

• Operating temperature: 0°C to +40°C

Put all of the installation’s convectors on Comfort 
(with the set-point on its maximum setting).
When the unit is switched on, a test lasting about
1 minute 30 seconds checks that the outputs are
correctly connected.
If the display remains “normal”, this means there 
are no problems.
If a problem exists, the DRIVER displays Pb - - .

Sortie et relance 

du mode test

Choix de la sortie à tester

Lancement du test

sortie par sortie

Validation et démarrage

du test de la sortie choisie

Exemple : test de la sortie 2

Output 2 test underway. 

Repeat the operations for zone 1.
Check the incorrect connections.
To exit test mode, press the init button.

Checking the pilot wire connections

DRIVER 610

DRIVER 620

Terminal 3

Convectors

zone 1

Convectors

zone 1

Terminal 4

Non Connected

Convectors

zone 2

N

L

N

L

Non

connected

Zone 1

Pilot Wire

Convectors

Zone 2

Pilot Wire

Convectors

Zone 1

Pilot Wire

Convectors

DRIVER

610

The room unit must be installed at a height of
approximately 1.5 m, so that it is within arm’s reach
for ease of use. To attach the unit to the wall, you
must separate it from its base. To do so, unlock the
casing.

Unscrew the terminal box cover and
lift it up as high as it will go to block it,
then position the base on the wall
running the wires out through the hole in the cover.
Secure the base using suitable screws  
and screw anchors or fit  
onto a flush-mounted box
(distance between  
centres 60 mm).
Connect the control wires.
Close the box and tighten
the terminal box cover
screw.

DRIVER

620

DRIVER

 

Room unit mounting

    Installation guide

www.deltadore.com

DRIVER 610 - 620

Pilot wire programmer 1 or 2 zones

DEL

TA DORE - 08/18

Exit and relaunch
test mode

Launch the test
output by output

Choose the output to test

Raccordement de la

sortie 2 

correct

Raccordement de la

sortie 2 

incorrect

OU

Le numéro de la 
sortie devient fixe

Le numéro de la 
sortie disparaît

Connection of output 2

incorrect

The output’s number

becomes fixed

The output’s

number disappears

Connection of output 2

correct

Approve and restart the test
for the chosen output
Example: test for output 2

Summary of Contents for DRIVER 610

Page 1: ...mpt to repair the unit yourself an after sales service is available Check that the fastenings are suited to the surface to which the unit will be attached plasterboard brick etc The diagrams provided...

Page 2: ...ation 1 or 2 pilot wires output 0 1A 230V Clock backup in the event of a blackout 2 hours per capacitor Dimensions WxHxD 80 x 103 x 16 mm Protection index IP 30 Installation in an environment with nor...

Page 3: ...the casing Unscrew the terminal box cover and lift it up as high as it will go to block it then position the base on the wall running the wires out through the hole in the cover Secure the base using...

Page 4: ...ER 620 Terminal 3 Convectors zone 1 Convectors zone 1 Terminal 4 Non Connected Convectors zone 2 N L N L Non connected Zone 1 Pilot Wire Convectors Zone 2 Pilot Wire Convectors Zone 1 Pilot Wire Conve...

Page 5: ...a sortie choisie Exemple test de la sortie 2 Output 2 test underway Repeat the operations for zone 1 Check the incorrect connections To exit test mode press the init button Checking the pilot wire con...

Page 6: ...u activate the unit you must set the clock Turn the selector dial to The days flash Press or to set the day then OK to confirm and go to the next setting Repeat these steps for the other menus To exit...

Page 7: ...ions menu 1 To enter the configuration menus turn the selector dial to then press and hold the i button for 5 seconds The unit will propose 2 configurations to choose After each menu has been configur...

Page 8: ...temperature taken with a thermometer and the temperature measured and displayed by the unit function 2 02 can be used to compensate for the difference by changing the way the sensor takes measurement...

Page 9: ...t Menu 2 Press 5s Press 5s The factory settings may be restored for each of the menus Turn the selector dial to then press and hold the i button for 5 seconds Repeat these steps for the other menus To...

Page 10: ...the connection on a Pilot Wire output Contact our technical department The i symbol flashes A fault is detected on the installation Press the button to view the fault s The device displays dEF and a...