Delta Controls DLC-G1212 Installation & Application Manual Download Page 13

Delta Controls 

Cautions and Warnings 

 

WARNING

 

The GE Lighting Controller is an Electro-statically sensitive device.  Proper ESD protection 
(ground strap) should be used when installing this product so that damage to the product does 
not occur. 
 

 
 

Compliance Declarations 

 

BACnet Testing Labs

 

The Delta Controller Engine (DCE) used in this product is BTL listed (with at least V3.22 firmware). 

Refer to 

http://www.bacnetassociation.org/bacnet_testing.htm

 for more detailed product listing information. 

 

 

BACnet is a registered trademark of ASHRAE.  ASHRAE does not endorse, approve or test 
products for compliance with ASHRAE standards.  Compliance of listed products to 
requirements of ASHRAE Standard 135 is the responsibility of the BACnet Manufacturers 
Association (BMA).  BTL is a registered trademark of the BMA. 

 
FCC Compliance Information 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, 
may cause harmful interference to radio communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be required to correct the interference at his 
own expense. 

 
Industry Canada Compliance Statement 

ICES-003   This Class A digital apparatus meets all requirements of the Canadian Interference-Causing 

Equipment Regulations 

 

Cet appareil numérique de la Classe A Respecte toutes les exigences du Règlement sur le matérial 
brouiller du Canada. 

 

Document Edition 1.5

 

 

Page 13 of 15 

Summary of Contents for DLC-G1212

Page 1: ...ching up to 12 GE lighting relay zones the GE Lighting Controller is ideal for mounting in various GE relay enclosures for both new and retrofit construction projects The controller also includes a bu...

Page 2: ...3 22 Firmware Software Important Information The capabilities of the GE Lighting Controller are dependent on the firmware version that is loaded The following is not intended to be comprehensive but s...

Page 3: ...ing Relay Outputs Maximum 4 GE Relays per output RR7x 3 wire Relays Control Only with No Status Delta PN 47101 Relays with no feedback RR9x 5 wire Relays Control and Status including LED Indication De...

Page 4: ...d jumpers or Software Setup DIP switch MAC Address Range 0 to 99 per network segment Software Address Range As per the BACnet standard Supports DNA Delta s intuitive addressing scheme Size Controller...

Page 5: ...E L 9 R E L 1 0 SWITCH 9 SWITCH 10 R E L 1 1 R E L 1 2 SWITCH 11 SWITCH 12 SC AN P W R RS O N OF F G ND RS O N OF F G ND RS O N OF F G ND RS O N OF F G ND RS O N OF F G ND RS O N OF F G ND RS O N OF...

Page 6: ...ing data through the port Inputs IP1 IP12 Input Status Indicators A corresponding red LED flickers when the associated binary input is in the active state Sweep Output OP13 Sweep Output Signal Indicat...

Page 7: ...mapped into the Subnet portion of its address inheriting other portions of its BACnet address when DNA is enabled DNA DERIVED NETWORK ADDRESSING DNA Derived Network Addressing DNA which works in conj...

Page 8: ...ON OFF GND POWER OUT GND BI1 SWITCH 3 RELAY 2 SWITCH 2 RELAY 3 RELAY 4 SWITCH 4 SWITCH 5 SCAN PWR RS ON OFF GND RS ON OFF GND RS ON OFF GND PILOT ON OFF GND FRONT VIEW BACK VIEW GE RS3xP LOW VOLTAGE...

Page 9: ...ropagation of 66 or higher Topology Ensure the MS TP network cable is installed as a daisy chain from one device to the next Max Nodes The maximum number of devices per MS TP network without any repea...

Page 10: ...ext 1000 or 300m maximum 3 Ensure you install MS TP terminator boards when you have more than 1 or 2 devices 4 Depending on the controller up to 12 devices are supported on a LINKnet network with limi...

Page 11: ...ed to represent two things Relay Output i e command Relay Status including when controlled by associated hardwired lighting switches E g To look for the Status Feedback Value the property you should u...

Page 12: ...BO object to a non feedback condition To set the Binary Output BO object to a non feedback condition 1 Open the BO associated with the RR7 relay 2 Under the Device Tab in the Module section there is a...

Page 13: ...CC Compliance Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reas...

Page 14: ...erconnected To Reduce the Risk of Fire or Electric Shock Use only Class 2 sources Suitable for Interconnection Use Copper Conductor Only Select an external power supply that is certified for safety fo...

Page 15: ...000 3 2 1999 Power Line Harmonics Class D EN 61000 3 3 1998 Power Line Fluctuations Pst 1 Plt 0 65 EN50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Immunity Level B EN...

Reviews: