3

Model: 

SIG80 / SIG80M /SIG80D/ SIG110 / SIG110H / SIG110D

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION

1.   Make sure that the electric service supply voltage is AC 

120V, 60Hz.

2.   Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the Occupational 
Safety and Health Act (OSH Act).

3.   Always disconnect the power source before working on or 

near the ventilating fan, motor or junction box.

4.   Protect the power cord from sharp edges, oil, grease, hot 

surfaces, chemicals or other objects.

5.  Do not kink the power cord.

6.   Do not install the unit where ducts are configured as 

shown in Fig.A.

7.  Provide suction parts with proper ventilation.
8.   This unit is UL Listed for use over a bathtub or shower 

when installed in a GFCI protected branch circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.   Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 
manufacturer.

2.   Before servicing or cleaning the unit, switch the power off 

at the service panel and lock the service disconnecting 
means to prevent the power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

3.   Installation work and electrical wiring must be done by 

a qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction.

4.   Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society 
for Heating Refrigeration and Air Conditioning Engineers 
(ASHRAE) and local code authorities.

5.   When cutting or drilling into the wall or ceiling, do not 

damage electrical wiring and other hidden utilities.

6.   Ducted ventilating fans must always be vented to the 

outdoors.

 GENERAL SAFETY INFORMATION

7.   If this unit is to be installed over a tub or shower, it must 

be marked as appropriate for the application and be 
connected to a GFCI (Ground Fault Circuit lnterrupter) – 
protected branch circuit.

8.   Do not use this unit with any other solid-state control 

device. Solid-state controls may cause harmonic 
distortion, which can cause a motor humming noise.

9.   NEVER place a switch where it can be reached from a 

tub or shower.

10.   Not to be installed in a ceiling thermally insulated to a 

value greater than R40. (This is required for installation 
in Canada only).

CAUTION

1.   For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.   Not for use in cooking areas. (Fig.B)
3.   This product must properly connect to the grounding 

conductor of the supply circuit.

4.   To  reduce the risk of injury to persons, install the fan at 

least 8.2 feet (2.5m) above the floor.

Turning angle too large

Duct shrink

y

d

o

b

 

e

h

r

a

e

n

 

w

o

b

l

E

s

w

o

b

l

e

 

y

n

a

m

 

o

o

T

Body

45°

Cooking area

45°

Do not install above or

  inside this area

 Cooking

Equipment

floor

 

Minimum 18 in.

Turning angle too large

Duct shrink

y

d

o

b

 

e

h

r

a

e

n

 

w

o

b

l

E

s

w

o

b

l

e

 

y

n

a

m

 

o

o

T

Body

45°

Cooking area

45°

Do not install above or

  inside this area

 Cooking

Equipment

floor

 

Minimum 18 in.

Fig. A

Fig. B

Summary of Contents for SIG110

Page 1: ...ckage Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions New Construction 5 Assembly Instructions Existing Construction 6 Grille Installation 10 Operation 10 Care and Maintenance 11 Troubleshooting 12 Dimensions 13 Product Specifications 13 Warranty 14 VENTILATION FAN MODEL SIG80 SIG80M SIG80D SIG110 SIG110H SIG110D ...

Page 2: ...NTENTS 1 2 3 4 5 PART DESCRIPTION QTY Fan Body 1 Grille 1 Suspension bracket Ⅰ 13 318 5mm 2 Suspension bracket Ⅱ 13 318 5mm 2 Duct Connector 1 A B C HARDWARE CONTENTS Images are to scale X 4 X 4 X 1 Long Wood Screw 4 x 25mm Short screw 8 32x1 4 Duct Screw M4x12mm ...

Page 3: ...pment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utili...

Page 4: ...ovide inspection and future maintenance access at a location that will not interfere with installation work You may need the help of a second person to install this fan one person on the attic side and one on the room side Note Installations may vary depending on how the previous bath fan was installed Supplies necessary for the installation of your bath fan are not all included However most are a...

Page 5: ...or joist spacing 16 in 24in insert suspension bracket I and suspension bracket II into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with nails and secure the suspension brackets to the fan body by using the short screws provided Hardware B Short screw NEW CONSTRUCTION ATTACHING TO THE JOIST Suspension Bracket II Suspension ...

Page 6: ... Reattach fan junction box cover c 5 Connect a 4 in circular duct a not supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and finish celling Mask protects unit during construction Remove before installing Grille c b a 4 joist joist a 5 6 Turn off power source Review al...

Page 7: ...an be sure to cut a 10 25 in x 10 25 in opening for the fan body 4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in Position the screws far enough away from the edge of the ceiling board that it does not crumble and give way Put screws in both ends of wood beyond the 10 25 in hole Keep screw...

Page 8: ...n page 4 Wire connections are as follows black to live switch wire white to neutral green to ground Reattach fan junction box cover c 7 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the wood support and 2 long wood screws through the flange into the joist Hardware A Long wood screw 8 Attach the duct connector from ...

Page 9: ...ws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Wire connections are as follows black to live switch wire white to neutral green to ground Reattach fan junction box cover c 3 Connect a 4 in circular duct a not supplied and vent to the outside Secure it with duct tape no...

Page 10: ...ER switch on to operate at humidity control mode the LED indicator will be blue When the ambient humidity is higher than the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the set point the fan will continue to run at the full speed until a 10 minute time delay has elapsed and then will automatically change to the user...

Page 11: ... immerse resin parts in water over 140º Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Wash and clean the grille in a sink and dry with a cloth 3 Remove dust and dirt from the fan body with a vacuum cleaner 4 Dampen cloth with dust detergent and wipe the fan body Then wipe dry with a clean cloth 5 Replace grill...

Page 12: ...rating on the fan matches the size of your room 2 Check damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the ...

Page 13: ... SP CFM Weight lb Max Current amps Note SIG80 120 60 8 7 80 10 0 30 Single Speed SIG80M 120 60 8 7 80 10 0 30 Motion Sensor SIG80D 120 60 8 7 80 10 0 30 Dual Speed SIG110 120 60 13 6 110 10 0 38 Single Speed SIG110H 120 60 13 6 110 10 0 38 Humidity Sensor SIG110D 120 60 13 6 110 10 0 38 Dual Speed Note Design and specifications subject to change without notice ...