Guarantee/technical specification

GUARANTEE AND TECHNICAL ASSISTANCE

The conditions of the guarantee and techni-

cal assistance are given on the certificate

supplied with your appliance.

LIMIT CONDITIONS

Room temperature 

21 ÷ 35°C

TECHNICAL SPECIFICATION

Power supply 
voltage 

see rating plate

Max. absorbed power 
during air conditioning 

Max. absorbed power 
during dehumidifying 

Refrigerant “

Cooling capacity 

Dimensions internal unit:

width 495 

mm

height  

940 mm

depth

410 mm

weight

34 kg

Transport, filling, cleaning, recovery and disposal of refrigerant should be performed by a tech-
nical service centre appointed by the manufacturer only.

The appliance should be disposed of  by a specialist centre appointed by the manufacturer only.

GB-5751012500  14-04-2004  15:59  Pagina 29

Summary of Contents for Pinguino T100ECO

Page 1: ...ECO Istruzioni per l uso pag 4 User manual pag 17 Mode d emploi et d entretien pag 30 Betriebsanleitung pag 43 Gebruiksaanwijzing pag 56 Instrucciones de uso pag 69 Manual de instru es pag 82 95 IT 57...

Page 2: ...sicher da Sie mit Ihrem Kauf zufrieden sein werden und das frische Wohlbefinden das Pinguino und SuperPin guino verbreiten ber eine lange Zeit genie en werden Wir bitten Sie sich etwas Zeit zu nehmen...

Page 3: ...E COMANDOS ACCESSORI ACCESSORIES ACCESSOIRES ZUBEH R ACCESSOIRES ACCESORIOS ACESS RIOS A B C F E D P Q R S H L N O M I T U G Modello T100ECO illustrato Model T100ECO illustrated Mod le T100ECO illustr...

Page 4: ...ppliance while the instructions aim to cover as many eventualities as possible caution and common sense should be used when operating and installing this air conditioning unit At the end of its workin...

Page 5: ...emitted into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas and then when hot and damp is discharged outside In models with case Super Pinguino th...

Page 6: ...sure the air exhaust hose is unob structed Open the window or French window sligh tly and position the outlet as shown in figure B 13 13 12 A Preparing for use B C Keep air hoses as short and free of...

Page 7: ...nge cap NOTE When installing the air conditioning unit semi permanently you should leave a door slightly open as little as 1 cm to guarantee correct ventilation 11 12 in the window pane in the wall yo...

Page 8: ...s and backwards When the appliance is turned off they will close irrespective of their position MODELS WITH REMOTE CONTROL UNIT model T100ECO only Operation Pressing the ON OFF button turns the applia...

Page 9: ...onditioning mode the indicator light M comes on To set operation of the appliance correctly press the G or O buttons until the required temperature is displayed The most suitable temperature for the r...

Page 10: ...tted into the rapid coupling as shown in fig I NB in order for continuous drain to function make sure the accessory is connected correctly to the coupling To release press the coupling flange FAN MODE...

Page 11: ...dby mode Press the timer button L The two centre segments flash on the display Use the G or O buttons to set the number of hours delay before the appliance comes on The indicator light H flashes until...

Page 12: ...the for mation of ice The appliance start up again automatically when the defrosting process is completed P PF F PROBE FAILURE sensor damaged If this is displayed contact your service centre FULL TANK...

Page 13: ...un by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air conditioning unit Never obstruct the air intake or outlet gri...

Page 14: ...The water should never be hotter than 40 C After washing leave the filter to dry To replace put the filters back in the intake grille then attach the intake grille to the appliance Never try and clean...

Page 15: ...r conditioning unit works but does not cool the room window open there are heat sources in the room burner lamp etc the exhaust hose is detached air filters clogged the air conditioning unit is not po...

Page 16: ...rating plate Max absorbed power during air conditioning Max absorbed power during dehumidifying Refrigerant Cooling capacity Dimensions internal unit width 495 mm height 940 mm depth 410 mm weight 34...