19

•  Never rest objects of any kind on the air conditioner.
•  Never obstruct the air intake or outlet flap.

CLEANING

Before  cleaning  or  maintenance,  turn  the  appliance  off  by         
touching the  

C1

C2

C4

C11

C13

C12

C9

C7

C5

C6

C3

C16

C14

C10

C15

C17

C8

 button, then unplug from the outlet.

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then 
dry with a dry cloth.  For safety reasons, never wash the air con-
ditioner with water. 

Attention! 

Never use petrol, alcohol or solvents to clean the ap-

pliance. Never spray insecticide liquids or similar.

CLEANING THE BIO SILVER AIR FILTER

The BioSilver filter helps capture dust and pollen and helps re-
duce the growth of bacteria and mold on the filter.
If the filter is dirty, air circulation is compromised and the effi-
ciency of the appliance decreases. It is therefore good practice 
to clean the filter at regular intervals. The frequency depends 
on the duration and conditions of operation.  If the unit is used 
constantly or systematically, you are recommended to clean the 
filter once a week.
The filter is housed in the intake grille.
To clean the filter, extract as shown in fig. 11.  
Use a vacuum cleaner to remove the dust collected on the filter. 
If it is very dirty, immerse in warm water and rinse a number of 
times. The water should never be hotter than 40°C.
After  washing  the  filter,  allow  it  to  dry  completely  before             
repositioning it.

START OF SEASON CHECKS

Make sure the power cable and plug are undamaged and the 
earth system is efficient.
Follow the installation instructions precisely.

END OF SEASON OPERATIONS

To drain all water from the circuit, remove the external cap by 
unscrewing it in the anticlockwise direction (fig. 12) and allow 
the water to drain out into a basin. 
When the appliance is empty, replace the caps. 
Clean the filter and dry thoroughly before putting back.

TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label

Max. absorbed power 
during air conditioning 

Refrigerant “
Cooling capacity 

 “

Frequency: 

2402.0-2480.0 MHz

Maximum transmission power 

0,00137 W

LIMIT CONDITIONS

Room temperature for air conditioning   

18° ÷ 35°C

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.
Attention!  

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will break down from lack of oil. 

Summary of Contents for Pinguino Air-to-Air PAC EL112CST

Page 1: ...lease note This appliance is provided with an auto evapora tion feature for condensate removal during cooling and dehu midifing modes AIR CONDITIONING WITHOUT INSTALLATION CASEMENT WINDOW If you have a casement window proceed as follows Fittheairexhausthose B2 intherelevanthousinglocated on the rear side of the appliance fig 1 Screw the window outlet B7 and place outside the win dow to exhaust the...

Page 2: ...9 Dehumidifying symbol C10 Fan symbol C11 ECO REAL FEEL indicator C12 SILENT symbol C13 Auto indicator C14 Air flow indicators C15 Alarm symbol C16 ECO REAL FEEL symbol C17 Set temperature values programmed on off time TURNING THE APPLIANCE ON OFF Before plugging the appliance check thecaponbackoftheunitiscorrect ly inserted on drainage hose A10 Insert the plug in the socket Two dashes appear on t...

Page 3: ...liance To correctly set this mode Touch repeatedly the MODE key until the fan symbol appears Select the desired air flow by touching the increase C4 or decrease C3 key The air flows available are Minimumairflow whenmostsilentoperationis desired Medium air flow when the noise level needs to be low but with a good comfort level Maximum air flow for maximum performance SELECT THE TEMPERATURE SCALE Th...

Page 4: ... D1 When turned on the air conditioner starts operating in the same mode as when it was turned off Touchthe C1 C2 C4 C11 C13 C12 C9 C7 C5 C6 C3 C16 C14 C10 C15 C17 C8 ON STAND BYbutton D1 againtoswitchthe appliance off Please note Never switch the appliance off by removing the plug Always switch it off by touching the C1 C2 C4 C3 ON STAND BY but ton D1 and waiting few minutes before removing the p...

Page 5: ...dledPinguino appliance In case the user wants to perform a pairing with an other Pinguino device or in case of a pairing of brand new CST remote control the user needs to put the unit in Stand by mode andkeeptouchedfor10secsthe MODE selectionbutton D6 on the CST remote control The Led D10 starts blinking periodi cally indicating the pairing phase The user is then asked to press for 10 sec the MODE...

Page 6: ...s previously set Tocancelthetimerprogram touchthetimerbutton D5 twice The timer symbol C7 will go off Pleasenote Oncethetimerhasbeenactivated bytouchingthe timerkeyonlyonetime theremaininghourstothestartupwill be displayed USAGE TIPS The CST remote control has humidity temperature sensors onboard It is suggested not to completely cover it with hands or clothes it is as well suggested not to place ...

Page 7: ...hotter than 40 C After washing the filter allow it to dry completely before repositioning it START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient Follow the installation instructions precisely END OF SEASON OPERATIONS To drain all water from the circuit remove the external cap by unscrewing it in the anticlockwise direction fig 12 and allow the ...

Page 8: ...bove there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appliance fig 1 filter clogged clean or replace the filter as described above the technical specification of the appliance is not adequate for the room in which it is located During operation there is an...

Reviews: