TECHNICAL CHARACTERISTICS:

Power supply  voltage

see rating plate

Max. power input 
during air conditioning

Absorbed power heating 
(certain models only)

Refrigerant

Cooling capacity

L

IMIT CONDITIONS

Room temperature for air conditioning

70÷95°F

21÷35°C

Room temperature for heating 

MAX 77°F   (MAX 25°C)

(certain models only) 

A

PPLIANCE DIMENSIONS

:

width

22 in

570  mm

height

35 in

910 mm

depth

18 in

465 mm

weight

112 lb

51 kg

19

570 mm

22 in

910 mm

35 in

475 mm

18 in

NEVER TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS
OCCURS, WAIT AT LEAST  4 HOURS BEFORE TURNING THE APPLIANCE ON
(RECOMMENDED TIME IS 24 HOURS).

This appliance is equipped with a 3 prong grounding plug. The plug must be connected into
an outlet that  is properly installed and grounded in the accordance with all local codes
and ordinances. Do not modify the plug provided with the appliance. If it will not fit the out-
let, have a proper outlet installed by a qualified electrician.
If the household electrical supply does not meet the above specifications, or if you are not
sure your home has an effective ground, have a qualified electrician or your local electrical
utility company check it and correct any problems.

Transport, filling, cleaning, recovery and disposal of refrigerant should be performed by a
technical service center appointed by the manufacturer only.
The appliance should be disposed of by a specialist center appointed by the manufacturer only.

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power cable.
If power is cut off, unplug from the socket and make sure the power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, contact a qualified electrician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off the power supply, check
that the power cable and plug are not damaged.
If the power cable is undamaged, to restore operation press the "RESET" button. 
To verify correct operation of the plug, press the "TEST" button periodically and make sure
the appliance disconnects. If this is not the case, contact the service center.
To restore operation, press the "RESET" button.

Summary of Contents for PAC W130E

Page 1: ...ustrated Visit www delonghiregistration com Visit www delonghi com for a list of service centers near you U S Only Enregistrez ce produit en ligne et recevez un num ro gratuit de Cook s Illustrated Vi...

Page 2: ...erations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combus...

Page 3: ...other in the home or be transported from one building to another Hot air from the room is passed through a coil cooled by refrigerant gas Excess heat and moisture are removed before the air is re emit...

Page 4: ...e hose door I Power cable compartment door J Water fill door K Air exhaust hose L Remote control M Water jug N Window outlet O Silver ion filter P 3M filter Q Suction pad with Velcro R Castor locks S...

Page 5: ...to hold the two parts of the window together fig 3 For optimum results If you have a sash window place the window bracket T on the window sill extend the window bracket fully within the window frame...

Page 6: ...window 11 In the wall it is recommended that you insulate the section of the wall using suitable insulation Fit the wall flange S into the hole Fit the air exhaust hose K in the housing at the back of...

Page 7: ...he rear hose increases FILLING THE TANK You can fill the tank in one of two ways 1 By using the water jug provided Use the water jug provided or any other plastic glass bottle or watering can providin...

Page 8: ...G FROM THE CONTROL PANEL The control panel enables you to manage all the main functions of the appliance but to fully exploit its potential you must use the remote control unit TURNING THE APPLIANCE O...

Page 9: ...peed for silent operation AUTOFAN the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display The most suitable temperature for the room d...

Page 10: ...available Maximum speed for maximum fan power Medium speed reduces noise levels but still maintains a good level of comfort Low speed for silent operation In this mode AUTO speed cannot be selected S...

Page 11: ...r ON button 22 OK button 23 Timer OFF button 24 SLEEP button 25 C or F selection button 26 Swing button function not available in this model 27 WATERSAVE button 28 Ionizer button 29 BOOST button USING...

Page 12: ...y flashes until the time is set Proceed as follows Press the or button until the correct time is reached Hold the button down to run rapidly through first the minutes then the tens of minutes and then...

Page 13: ...the dehumidifying power of the applian ce is partially reduced every hour for the first two hours WATERSAVE FUNCTION FIG 26 This function is designed to increase the operating time of the appliance w...

Page 14: ...F DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are indicated on the control panel display screen IF IS DISPLAYED WHAT SHOULD I DO LOW TEMPERA...

Page 15: ...S The appliance is fitted with a dust filter which retains impurities in the air drawn in from the room Certain models also include other filters with a high filtering capa city namely a silver ion fi...

Page 16: ...g it from the grille Fig 36 Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a num ber of times The water should never be hotter than...

Page 17: ...the inside of the appliance through the drain hoses fig 37 Close and replace the drain hoses Pour 0 5 Liters of descaler one bottle and 1 5 Liters of clean water into the tank Plug in and operate the...

Page 18: ...esent silver ion filter and 3M filter clogged The technical specification of the appliance is not adequa te for the room in which it is located Close doors windows and curtains bearing in mind the tip...

Page 19: ...ove specifications or if you are not sure your home has an effective ground have a qualified electrician or your local electrical utility company check it and correct any problems Transport filling cl...

Page 20: ...r and shipping are to be paid by the owner of the unit This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions that accompa ny it and on an Alternating...

Reviews: