10
FOR U.K. ONLY
Wiring instructions
This appliance must be earthed
Important: The wires in this lead are coloured in accordance with the following codes:
Green and yellow:
Earth
Blue:
Neutral
Brown:
Live
Connect the green/yellow wire to the terminal in the plug marked “E”
(or by the earth symbol) or coloured green or coloured green and yellow.
Connect the brown wire to the terminal in the plug marked “L”
or coloured red.
Connect the blue wire to the terminal in the plug marked “N” or coloured
black.
A 13 amp fuse should be fitted when the appliance is connected to a BS 1363 plug.
Seek professional advice if you are unsure of the correct procedure for the above.
About your factory fitted plug
(supplied with certain models only)
The lead is already fitted with a plug incorporating a 13 amp fuse. If the plug does not fit your
socket outlet, see next paragraph. Should you need to replace the fuse in the plug supplied, a
13 amp approved BS 1362 fuse must be used. (refer to wiring instructions for use rating) If the
plug supplied does not fit your socket outlet, it should be removed from the mains lead and dis-
posed of safely. The flexible cord insulation should be stripped back as appropriate and a suit-
able alternative plug fitted. The replacement plug must be equipped with a 13 amp fuse.
Important: If the electrical cord of this appliance is damaged, it must only be replaced by an au-
thorised Service Dealer. The safety of this appliance complies with the technical regulations and
standards in force.
Green and Yellow or green
Blue or
black
Fit13
amp
fuse
Brown
or red
Use cable
gripper
Summary of Contents for EO-1200.1
Page 11: ...5711810511 06 10...