![DeLonghi DL 48 P6G Installation Instructions Manual Download Page 26](http://html.mh-extra.com/html/delonghi-0/dl-48-p6g/dl-48-p6g_installation-instructions-manual_2470780026.webp)
26
Conduit
Neutral Wire
Power Wires
Conduit Clamp
Terminal Block
Ground strap
Conduit
Bracket
Conduit
Neutral Wire
Power Wires
Conduit Clamp
Terminal Block
Cut Ground strap
Conduit
Bracket
Grounding
Screw
Grounding Wire
4-Wire Conduit Installation
(See Figures 3.1, 3.7, 3.8 and 3.10)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(Figure 3.1).
2. Remove the
Bracket
and
Strain Relief
group by unscrewing
the
Bracket Fixing Screws
(Figure 3.7).
3. Mount the
Conduit Bracket
(supplied with the range in a sep-
arate kit - make sure you are using the correct
Conduit
Bracket
as indicated in Figure 3.8) inside the
Opening For
Electrical Connection
by screwing the 2
Fixing Screws
(as
indicated in Figure 3.8).
4. Feed 1/2” (1.3 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
(Figure 3.10).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
6. Remove the
Ground Strap
from the frame of range and ter-
minal by removing its screw and cutting it as shown in Figure
3.10.
7. Plug the terminal holes of conductors. The
Neutral Wire
of
the
Power Cord
must be connected to the neutral terminal
located in the center of
Terminal Block
; the
Power Wires
must be connected to the outside terminals; the
Ground Wire
must be attached to the frame of range by using the
(Ground) identified
Grounding Screw
.
8. Plug washers and tighten nuts securely.
9. Assemble the
Terminal Block Access Plate
(Figure 3.1).
Fig. 3.9
Fig. 3.10
Strain Relief
Bracket
Bracket
Fixing Screws
Conduit
Bracket
Opening For
Electrical
Connection
Fixing Screws
B
: D=7/8" (22.5 mm)
A
: D=1" 9/64 (29 mm)
3-Wire Conduit Installation
(See Figures 3.1, 3.7, 3.8 and 3.9)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(Figure 3.1).
2. Remove the
Bracket
and
Strain Relief
group by unscrewing
the
Bracket Fixing Screws
(Figure 3.7).
3. Mount the
Conduit Bracket
(supplied with the range in a sep-
arate kit - make sure you are using the correct
Conduit
Bracket
as indicated in Figure 3.8) inside the
Opening For
Electrical Connection
by screwing the 2
Fixing Screws
(as
indicated in Figure 3.8).
4. Feed 1/2” (1.3 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
(Figure 3.9).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
6. Plug the terminal holes of conductors. The
Neutral or Ground
Wire
of the
Power Cord
must be connected to the neutral
terminal located in the center of
Terminal Block
. The
Power
Wires
must be connected to the outside terminals.
7. Plug washers and tighten nuts securely.
8. Assemble the
Terminal Block Access Plate
(Figure 3.1).
Fig. 3.7