DeLonghi DEC12-14 Manual Download Page 9

20

Tr o u b l e s h o o t i n g  

Problem

Cause

Remedy

The appliance does not
work in dehumidifying
mode (indicator light off)

The appliance operates in
dehumidifying mode (light
on) but the humidity is not
reduced

•the appliance is not plug-

ged in

•there is no current
•the humidistat is on mini-

mum

•the tank is full of water
•the tank is incorrectly posi-

tioned

•filter clogged
•the temperature or humi-

dity of the home is too
low

•room too large
•too many sources of humi-

dity in room (boiling pots
etc.)

•plug into the mains
•check the power supply
•turn the humidistat to the

max position.

•empty the tank
•gently place the tank in

the correct position

•clean the filter
•in certain conditions, it is

normal for the appliance
not to dehumidify (in these
cases the room being
dehumidified should also
be heated)

Check the following points before calling your local Technical Service Centre.

The air conditioner doesn’t
work for about 3 minutes
from turning on the applian-
ce

•the appliance’s security

system has intervened 

•wait for 3 minutes

Summary of Contents for DEC12-14

Page 1: ...than 10 C for prolonged periods low level heating will be necessary to allow the condensate to evaporate into the air before dehumidification can take place The air will however be slightly warmed by...

Page 2: ...sate drain hose some models only rubber bung DEC12 14 DEC18 2 1 1 Control panel 2 Control panel cover 3 Air outlet grille 4 Condensate collection tank 5 Lifting handle 6 Air intake grille 7 Electrosta...

Page 3: ...urfaces Keep the unit at least 50 cm away from inflammable substances alcohol etc or pressurised containers eg aerosol cans Do not rest heavy or hot objects on top of the appliance Clean the air filte...

Page 4: ...The condensate can be drained directly into the tank located inside the appliance fig 2 The tank can be easily removed and has a handle making it simple to carry and empty B Continuous external drain...

Page 5: ...tion knob 1 Plug the appliance into a mains socket 2 Check that the tank full tank missing light is off 3 Select the or or the dehumidification standby light switches on in the first 3 minutes safety...

Page 6: ...rifies in all the other dehumidification functions Low consumption dehumidification function When the set humidity level in the room is reached the appliance stops In cases where dehu midifying is req...

Page 7: ...appliance is effectively dehumidifying if the humidity in the room is already low enough the light will be off Dehumidification standby low temperature operation light The light switches on in the fo...

Page 8: ...atically you are recommended to clean the filter once a week To remove the air filter extract by pulling it as shown in fig 5 Use a vacuum cleaner to remove dust accumulations from the filter If the f...

Page 9: ...oo low room too large too many sources of humi dity in room boiling pots etc plug into the mains check the power supply turn the humidistat to the max position empty the tank gently place the tank in...

Page 10: ...d power Maximum absorbed current Defrosting device yes Humidistat yes Fan speeds 1 2 Air filter yes Purifying filter no yes Dimensions LxHxP 570x360x300mm Tank capacity 4 liters Operating limits Dehum...

Reviews: