Installation of the outdoor unit drain line (if available)
During operation in the heating mode, the condensate water
may be drained from the outdoor unit through three drain
holes.
Insert the drain male fitting into the hole where drainage of
the condensate water is required and plug the remaining
two holes using the plugs B supplied in the kit, as shown in
Fig.(14).
FLOOR INSTALLATION
Installation on a floor or flat roof does not necessitate fixing
the feet to the floor. The feet should instead be placed on
supports (~70÷80 mm) to allow application of the conden-
sate drain line (for units with heat pump only).
The minimum distances shown in the figure should be
observed. Fig.(15).
SUSPENDED INSTALLATION
The minimum spaces indicated should be observed for
suspended installation, which requires a support kit that
must be ordered separately.
Carefully check the structure and the capacity load of
the supporting wall. Fig.(16).
Fig. 14
Fig. 15
Fig. 16
100 mm
200 mm
100 mm
100 mm
A
B
C
D