background image

 

 

 

4. 

Down Arrow Key:

  Press and hold to decrease the alarm setting. 

5. 

Up Arrow Key:

  Press and hold to increase the alarm setting. 

 

OPERATION 

Checking the Battery and Calibration  

  The meter automatically checks the battery level when it is turned on.  If the 

battery voltage is not high enough for reliable operation, all indicators will flash 
for a few seconds. Replace the battery with a new one (9v alkaline).  

 

To check the meter’s calibration, turn the meter on. Press and hold the Cal 
Check key. Hold the meter in the air so that only the internal reference is read. 
The meter must read within the blue calibration check band. If the meter reads 
out of calibration refer to the Service for Your Meter section (pg8).    

Taking a Reading 

  Press the On/Hold key to turn the unit on. 

  Press the Scale key to select the Wood or the Reference scale.  

  When the meter is set to wood, the panel meter wood scale is calibrated to show 

%MC based on the average specific gravity of Douglas Fir (0.46).  

  When the meter is set to the reference scale, the meter switches to a lower 

sensitivity mode which is suitable for a wide range of materials.   

  Press the On/Hold key while reading to hold (or freeze) the current reading.  The 

meter will beep slowly and continue to hold the reading until the On/Hold key is 
pressed again. 

  The alarm (fast beep) will sound whenever the current reading is above the alarm 

setting. 

Setting the Alarm 

  With the meter turned on, press the Up or Down arrow keys to adjust the alarm 

setting.  When the Alarm Setting is being adjusted, the Alarm Setting indicator 
lights and the panel meter shows the alarm setting.  

  The range of alarm settings is 5.0 to 30.0 for wood and 1 to 100 for the reference 

scale.  The meter stores separate wood and reference alarm settings.  

  To turn the alarm off, use the Up key to adjust the alarm setting beyond the end 

of the scale.  The Alarm Setting indicator flashes when the alarm is turned off.  

  Exit the Alarm Setting mode by pressing the On/Hold key.   

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for TechScan

Page 1: ...TechScan v 1 1 Owner s Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ERATION 4 TIPS FOR USING TECHSCAN TO MEASURE WOOD 5 TIPS FOR USING TECHSCAN TO MEASURE RELATIVE MOISTURE 6 CARING FOR YOUR METER 8 SERVICING YOUR METER 8 WARRANTY 8 ADDENDUM 10 www GlobalTestSupply co...

Page 3: ...or need to penetrate through flooring check behind drywall or test lumber over 1 1 2 thick we recommend using TechScan in conjunction with a Delmhorst resistance pin type moisture meter TechScan has t...

Page 4: ...e depends on the material used for calibration and on the meter s range SWITCH KEY FUNCTIONS 1 On Hold Key Press to turn meter on resume reading after checking calibration or setting alarm or hold cur...

Page 5: ...verage specific gravity of Douglas Fir 0 46 When the meter is set to the reference scale the meter switches to a lower sensitivity mode which is suitable for a wide range of materials Press the On Hol...

Page 6: ...readings Test the insulating material with the meter first to confirm it provides the necessary insulation The meter works best on smooth lumber and surfaces Rough uneven or cupped boards yield lower...

Page 7: ...and also a table to correct meter readings for wood species Use these values with the knowledge that specific gravity varies within a single species and may even vary within the same board The follow...

Page 8: ...nd F2420 RH on surface using insulated hood provide quantitative information for determining if moisture levels are within specific limits Using TechScan In A Water Damage Restoration Or Mold Remediat...

Page 9: ...does not resolve the problem go to www delmhorst com and follow the instructions under Product Support If you require further assistance please call 877 DELMHORST 335 6467 or 973 334 2557 WARRANTY De...

Page 10: ...PRODUCT The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and no other warranty written oral or implied applies This warranty is personal to the cu...

Page 11: ...ENDUM 1 Specific Gravity Correction Table TechScan Meter Readings vs MC April 2013 2 TechScan Species Botanical SG List April 2013 www GlobalTestSupply com Find Quality Products Online at sales Global...

Page 12: ...11 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 13: ...12 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 14: ...13 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 15: ...14 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Reviews: