background image

USING THE METER IN THE
CONTINUOUS MODE

h

Change the set-point 

to the desired value as described on

page 3. This must be done prior to turning the meter on.

h

Plug the external power supply 

into the side of the meter.

This will automatically put the meter in the continuous
mode. Once power is supplied,  the backlight will turn on
and remain on until the external power is removed.

h

Turn the meter on

by pressing the read key 

!

. A decimal

point will display for a few seconds and then the meter will
begin displaying the average and highest readings. 

When the meter is operating continuously, it takes two
readings every second, and accumulates eight readings
before calculating their AVERAGE and HIGHEST val-
ues. After all eight readings have been taken, the meter
will begin a new read cycle. 

The meter displays the aver-

age as Axx.x and the highest as xx.x alternately for two
seconds each. 

h

Turn the meter off

by either removing the external power

supply or pressing and holding the calibration check key

@

until the meter is off. The backlight will stay on until

the power supply is removed.

Notes

h

Start tractor before powering up meter. 

h

Disconnect meter before shutting down tractor.

ABOUT YOUR READINGS

The meter reads between 6% and 40%. Readings below 6%
are displayed as “.0” and are used in calculation as 7.5%;

 

readings above 40% are displayed as “99.9” and are used in

 

calculation as 45%.

Readings obtained while using the FX-2000 in its continuous

 

mode are usually higher than those obtained when probing

 

the bale by hand. Under normal conditions, expect the con-
tinuous readings to be around 2-4 points higher on average.

 

Tests show this difference can be even greater, especially on

 

large square bales, depending on overall conditions.

Do not be concerned that such differences exist. However, it

 

is important to have a feel for what the difference is since

 

conditions in the field change rapidly.

We recommend that you spot check the windrow and freshly 
made bales to give additional information with regard to 
these differences and to help establish the appropriate range 
for baling.

CARE OF YOUR METER

To keep your meter in good working order:

h

Store your meter in a clean, dry place. The optional

protective carrying case is an ideal storage place when
the meter is not in use.

h

Change the 9-Volt battery as needed. Continued use with a

low battery may cause the meter to go out of calibration.

h

Clean the meter and probe with any biodegradable cleaner.

Use the cleaner sparingly and on external parts only. 

Do

not immerse the meter or any prod in water.

h

Remove the battery if the meter will not be used for one

month or longer.

WARRANTY

Delmhorst Instrument Co., referred to hereafter as
Delmhorst, guarantees its FX-2000 meter for three years
from date of purchase and any optional electrodes against
defects in material or workmanship for 90 days. If, within
the warranty period of the FX-2000, you find any defect in
material or workmanship return the meter following the
instructions in the 

Service for Your Meter

section. This limited

warranty does not cover abuse, alteration, misuse, damage
during shipment, improper service, unauthorized or unreason-
able use of the meter or electrodes. This warranty does not
cover batteries, pin assemblies, or pins. If the meter or any
optional electrodes have been tampered with, the warranty
shall be void. At our option we may replace or repair the
meter.
Delmhorst shall not be liable for incidental or consequential
damages for the breach of any express or implied warranty
with respect to this product or its calibration. With proper care
and maintenance the meter should stay in calibration; 
follow the instructions in the 

Care of Your Meter

section. 

The express warranty set forth above constitutes the entire

 

warranty with respect to Delmhorst meters and electrodes

 

and no other warranty, written, oral, or implied applies. This

 

warranty is personal to the customer purchasing the product

 

and is not transferable.

SERVICE FOR YOUR METER

If your meter is not working properly, replace the battery with
a new one and check the calibration. If this does not resolve
the problem please send your meter back to Delmhorst for
repair. Go to www.delmhorst.com and click on Support and
then download the Return Form. If you require further assis-
tance please call 877-DELMHORST (335-6467) or 973-334-
2557. E-mail [email protected]

UNDER NO CIRCUMSTANCES SHALL DELMHORST BE

 

LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL,

 

OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHAT-
SOEVER, INCLUDING, BUT NOT LIMITED TO, LOST

 

PROFITS OR DOWNTIME ARISING OUT OF OR RELAT-
ED IN ANY RESPECT TO ITS METERS OR ELEC-
TRODES AND NO OTHER WARRANTY, WRITTEN, ORAL

 

OR IMPLIED APPLIES. DELMHORST SHALL IN NO

 

EVENT BE LIABLE FOR ANY BREACH OF WARRANTY

 

OR DEFECT IN THIS PRODUCT THAT EXCEEDS THE

 

AMOUNT OF PURCHASE OF THIS PRODUCT.

Reviews: