background image

If the meter still indicates green or “dry” the floor is ready for covering. Tests should be made at several points, especially when the 
slab is thick and air circulation is poor. 
Tests should only be made in newly drilled holes, since the  inside surface of the holes can dry out while the rest of the  slab is still 
wet. 
 
Even readings in the red or “wet” area can indicate relatively low moisture content in concrete. For example, readings in the 85-95 

range on the reference scale

indicate approximately 2% to 4% moisture content. 

 
If more testing is required, the calcium chloride test is  recommended, which measures the moisture vapor emission  rate of 
concrete. The National Wood Flooring Association 
offers the following guidelines when evaluating the results of the calcium chloride test***. 
 

 

 

Key Factors to Consider: 

 

 

The age of the slab. 

National Wood Flooring Association guidelines specify to wait at least 30 days after the slab is laid 

before checking moisture content. *** 

 

 

Is the slab on grade or suspended? 

If the slab is on grade, is there an effective vapor barrier under the slab?  

 

 

How thick is the slab? 

 

 

What is the drainage condition  of the ground? 

 

 

History  of other structures in the area 

 

***Taken from Section V Appendix AA 

 

“Moisture Testing Procedures for Concrete Slabs” — NWFA 

 

 

Testing Brick or Concrete for Paint Application 

 
Brick, stucco, or concrete surfaces must be dry at the time of application and must remain dry after paint is applied or failure of the 
paint film may occur. These materials are frequently exposed to unusual moisture conditions that allow them to absorb   moisture 
through some exposed surface or some structural defect. This is why it is   important to check the moisture content of the brick or 
concrete when it has been exposed to conditions that permit it to absorb moisture. 
 

Procedure: 

 

 

Drive two hardened steel masonry nails 

about 19mm (

¾”) apart into the brick or concrete. Drive them about 6.4mm 

(¼”) deep so they make firm contact and do not move when touched. 

 

Touch the nails 

with the contact pins 

 

Press read button

and read the reference scale 

 
Normally, dry concrete or brick will read in the green or “dry” portion of scale, indicating a safe condition to apply paint. Meter 
readings should be evaluated in relation to other factors 

— knowledge of the structure, type of paint used, expected weather 

conditions in the near future, etc. Paint should not be applied if 

readings are in the red or “wet”  portion of the scale. 

 
Do not be misled by surface appearance of masonry materials. Short exposure to rain may thoroughly wet the surface while  the 
interior is still dry. In this instance, we recommend repeating the test on the masonry 

below the surface 

as mentioned above. 

 
 

Key Areas to Check: 
 

 

The rear side of brick parapet walls 

— 

generally are not waterproof above the flashing line and frequently absorb 

moisture during rains. 

 

Painted concrete floors on ground 

— 

subject to peeling as  they absorb moisture from the earth, unless an effective 

vapor barrier has been installed. 

 
Tests on these materials should be made a day or so after they have been exposed to rain or other high moisture conditions to  
verify  to what extent they absorb moisture. 

Summary of Contents for BD-10

Page 1: ...BD 10 BUILDING MATERIALS MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Page 2: ...5 EIFS Exterior Insulation Finish Systems 5 Using 0 100 Reference Scale 5 Testing Concrete Slabs for Flooring Applications 6 Testing Brick or Concrete for Paint Application 7 Testing Plaster Walls Sh...

Page 3: ...staccurate method for measuring moisture 6 40 moisture range for wood 0 to 100 reference scale for non wood materials Analog readout Built in calibration check Temperature stable circuit Ergonomic cas...

Page 4: ...ING A READING Remove the protective cover to expose the pins Check that the contact pins are firmly hand tightened USING 6 40 WOOD SCALE Align contact pins parallel to the grain pushing to their full...

Page 5: ...mid section ofthe slab especiallyif the slab is on or below grade This will help determine ifthere is continuous moisture migration toward the surface If this condition exists the moisture movementma...

Page 6: ...ccur These materials are frequentlyexposed to unusual moisture conditions thatallow them to absorb moisture through some exposed surface or some structural defect This is why it is importantto check t...

Page 7: ...meter The following guidelines maybe used to interpretthe meter readings on plaster or sheetrock prior to painting or applying adhesives Green or dry 4 moisture Red or wet approximately5 Yellow Borde...

Page 8: ...protective carrying case provided is an ideal storage place when the meter is not in use Change the 9 Volt battery as needed Continued use with a low battery may cause the meter to go out of calibrat...

Page 9: ...instructions in the Care of Your Meter section Under no circumstances shall DELMHORSTbe liable for any incidental indirect special or consequential damages ofany type whatsoever including butnot limi...

Page 10: ...10...