We recommend that you spot check the windrow and freshly
made bales to give additional information with regard to
these differences and to help establish the appropriate range
for baling.

CARE OF YOUR METER

To keep your meter in good working order:

h

Store your meter in a clean, dry place. The optional

protective carrying case is an ideal storage place when
the meter is not in use.

h

Change the 9-Volt battery as needed. Continued use with a

low battery may cause the meter to go out of calibration.

h

Clean the meter and probe with any biodegradable cleaner.

Use the cleaner sparingly and on external parts only. 

Do

not immerse the meter or any prod in water.

h

Remove the battery if the meter will not be used for one

month or longer.

WARRANTY

Delmhorst Instrument Co., referred to hereafter as

 

Delmhorst, guarantees its FX-2000 meter for three years

 

from date of purchase and any optional electrodes against

 

defects in material or workmanship for 90 days. This limited

 

warranty does not cover abuse, alteration, misuse, damage

 

during shipment, improper service, unauthorized or unreason-

able use of the meter or electrodes. This warranty does not
cover batteries, pin assemblies, or pins. If the meter or any
optional electrodes have been tampered with, the warranty
shall be void. At our option we may replace or repair the
meter.

Delmhorst shall not be liable for incidental or consequential
damages for the breach of any express or implied warranty
with respect to this product or its calibration. With proper care
and maintenance the meter should stay in calibration; 
follow the instructions in the 

Care of Your Meter

section. 

Under no circumstances shall Delmhorst be liable for any
incidental, indirect, special, or consequential damages of any
type whatsoever, including, but not limited to, lost profits or
downtime arising out of or related in any respect to its 

16

FX-2000 B&W manual:FX-2000 B&W manual 50406Q5  12/10/08  8:57 A

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 50406Q5

Page 1: ...FX 2000 o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T TM FX 2000 B W manual FX 2000 B W manual 50406Q5 12 10 08 8 57 A www com information itm com 1 800 561 8187...

Page 2: ...Density 10 Use of Preservatives 11 Sample Size 11 To Use Meter For Continuous Monitoring 12 To Install The 1986 Bale Sensor 13 Installation on an Inline or Center Line Small Square Baler 13 Installati...

Page 3: ...c case design hIncludes 1 9 volt battery hThree year warranty h60 years of proven quality accuracy and service Digital Readout Read Button Calibration Check Button Set Point Increase Set Point Decreas...

Page 4: ...r will alert you if the meter reads higher than the selected MC Also operates the back light in the portable mode When the battery is replaced the meter displays its software version for one second an...

Page 5: ...nt decrease button and the set point value will decrease hWhen scrolling in either direction release the button to stop at your desired set point If the meter reads a MC higher than that of the set po...

Page 6: ...calibration check button Within one second press and hold the set point increase button hHold the set point increase button until the backlight turns on The backlight will be activated and remain lit...

Page 7: ...easured repre sents the hay in contact with the tip of the prod only hPartially cured hay may have wide variations in moisture content throughout the bale Readings should be taken in several different...

Page 8: ...t with the hay sample hPress the read button and take a reading hMix the sample once again and take at least two more readings Use the highest readings Notes hWhenever pressure is being applied on the...

Page 9: ...one at a time across two adjacent points on the 831 short pin prod hThe average of these stem readings should be about two to five points higher than the actual moisture content Notes hRepeat these s...

Page 10: ...a few high readings indicate that some action be taken to dry the hay to avoid spoilage or even self combustion While it is important to note the average of several readings it is even more important...

Page 11: ...readings 1 2 points higher hLooser bales tend to yield 1 2 point lower hTests in stacks usually yield readings 2 3 lower hTests on grass hay may yield readings about 3 lower Baling should be done acco...

Page 12: ...sture areas samples from these locations should be taken Areas of high moisture content will spoil resulting in loss It is extremely important to note the high readings and the frequency at which they...

Page 13: ...e mounting holes File any burrs from the holes hInstall the sensor plate with only the bale chamber wall between it and the backplate The beveled edge of the insu lation must face the plunger opposite...

Page 14: ...ditional protection to the sensor plate Installation on a John Deere Round Baler hLocate a spot on the right hand side of the bale chamber approximately 4 5 up from the bottom of the frame The back ed...

Page 15: ...baler Installation on all other Round Balers hLocate a spot on the side wall or tailgate on either side of the baler as low as possible to the bottom hFollow instructions for installation as above Be...

Page 16: ...ter off by either removing the external power supply or pressing and holding the calibration check button until the meter is off The backlight will stay on until the power supply is removed Notes hSta...

Page 17: ...nal electrodes against defects in material or workmanship for 90 days This limited warranty does not cover abuse alteration misuse damage during shipment improper service unauthorized or unreason able...

Page 18: ...purchase of this product The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and electrodes and no other warranty written oral or implied applies This...

Page 19: ...o hygrometers Today we offer the innovative KIL MO TROL in kiln monitoring system We also offer a wide range of meters for a variety of applications including wood working lumber agriculture con struc...

Reviews: