To activate the backlight, tap the ON/OFF button.  Tap the ON/OFF button again to 
turn off the backlight. 
 

LOW BATTERY: 

 
A “low battery” indication will appear on the display when voltage is no longer 
sufficient. Immediately replace the battery (9V Alkaline only). Typical battery life is 
approximately 55 hours (without backlight). 
 

ADJUSTING THE DISPLAY CONTRAST: 

 
The display contrast is preset in the system memory at an optimal level. Under most 
operating conditions, no further adjustment should be necessary. However, if the 
meter is operated in extreme temperature conditions, some adjustment may be 
desirable for optimal viewing quality.  
 
Procedure:  
 
1.  Ensure the meter is not in HOLD mode. Press and hold the ON/OFF button. 

Keep it pressed throughout the adjustment process. 

2.  To turn the display darker, press and hold the SCALE (F/C) button within 2 

seconds. Release this button when desired contrast is achieved. 

3.  To turn the display lighter, press and hold the ROTATE button within 2 seconds. 

Release the button when the desired contrast is achieved. 

4.  Once the desired contrast is achieved, release the ON/OFF button within 2 

seconds. 

 

OPERATION SUMMARY: 

 

 

On/Off 
(Hold) 

Hold Rotate Scale On/Off 

 

(Tap) 

On/Off 

Scale 

On/Off 

Rotate 

Turns 
meter ON 
and OFF if 
held for 
longer 
than 2 
seconds 

Places 
meter in 
HOLD 
mode: 
current 
data is 
held, all 
data is 
available 
for display 

Alternates 
between 
T/RH and 
D/AH data 
set 
displayed 
on screen 

Alternates 
between F 
and C 
scales for 
Temp. and 
Dew Point 
readings 

Alternates 
the state 
of the 
backlight 

Contrast 
adj – turns 
display 
darker. 

Contrast 
adj– turns 
display 
lighter. 

Summary of Contents for HT-3000

Page 1: ...LE OF CONTENTS 3 INTRODUCTION 3 OPERATION 3 AUTO OFF 3 BACKLIGHT 4 LOW BATTERY 4 ADJUSTING THE DISPLAY CONTRAST 4 OPERATION SUMMARY 5 CALIBRATION MAINTENANCE 5 TECHNICAL SPECIFICATION Measurement Accuracy Response Time Resolution Power Supply Battery Life 6 CARE OF YOUR METER 6 SERVICE FOR YOUR METER 7 WARRANTY ...

Page 2: ... 2003 DELMHORST INSTRUMENT CO 2 of 2 SCALE ROTATE HOLD ON OFF ...

Page 3: ...the meter memory after power up This allows immediate access to any measured or calculated value even if the data of interest is not currently displayed 4 Press the SCALE F C button at any time to switch Temperature and Dewpoint readings between Fahrenheit and Celsius 5 Press the HOLD button to freeze the displayed readings The letter H appears at the right of the first display line The meter stop...

Page 4: ... mode Press and hold the ON OFF button Keep it pressed throughout the adjustment process 2 To turn the display darker press and hold the SCALE F C button within 2 seconds Release this button when desired contrast is achieved 3 To turn the display lighter press and hold the ROTATE button within 2 seconds Release the button when the desired contrast is achieved 4 Once the desired contrast is achieve...

Page 5: ...ibration is not available for the HT 3000 TECHNICAL SPECIFICATIONS Measurement Temperature 20 C to 70 C 4 F to 158 F Relative Humidity 0 100 RH Dew Point 40 C to 80 C 40 F to 176 F Absolute Humidity 0 55 gpp to 3868 gpp Accuracy Temperature 1 C over 0 C 70 C 1 8 F over 32 F to 158 F Relative Humidity 3 Response time Temperature reaches 80 of full excursion in approx 75 seconds Relative Humidity re...

Page 6: ...ructions prior to returning a meter Include your name address daytime phone and fax numbers or e mail address If you believe the meter is under warranty please provide the original sales slip or invoice Ship via UPS Express Mail Priority Mail or any overnight courier who provides prompt service Do not use standard parcel post Insure your instrument for its full value and ship prepaid We are not re...

Page 7: ...duct or its calibration With proper care and maintenance the meter should stay in calibration follow the instructions in the Care of Your Meter section Under no circumstances shall Delmhorst be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to its meters or ele...

Reviews: