5I DELLMECO I AODD DIAPHRAGM PUMPS 

 

 

 

 

 

 

!!!!    

WARNING 

!!!!    

CAUTION 

!!!!

 

When installing this product, be sure to connect a ground wire from the specified position of this product. 

Otherwise  friction  between  parts  and  abrasion  caused  by  the  flow  of  some  fluids  inside  the  casing  may 
generate  static  electricity.  Depending  on  the  type  of  fluid  being  pumped  and  the  installation  environment 
(such  as  gases  in  the  air  and  type  of  surrounding  mixtures),  static  electricity  could  cause  fire  or  electric 
shock. 

 

!!!!

 

Some fluid may remain inside the pump and inside the connected piping after shutting down the pump, or if 
the pump is left unused for a prolonged period. 

 

Therefore, be sure to purge the system of fluid and clean the pump before prolonged disuse. 

The  fluid  remaining  in  the  connected  piping as  well as the pump  itself  may  expand  because of  freezing  or 
heat which may cause damage to the pump or/and piping and lead to leakage of the fluid. 

 

 

Ø 

 Use only genuine Dellmeco parts when replacing component parts of this product. 

 

!!!!

 

Torque of all tightening parts must be checked before running the pump. Designated torques are mentioned 
in maintenance manual. 

 

!!!!

 

In case of pumping a hazardous fluid (hot, flammable, strong acid, etc.) with this pump, protective measures 
(install a pit, a protection box, sensors, etc.) must be provided in consideration of possible leakage of fluid. 
Warning signs must be displayed at necessary places. Leakage of fluid may cause fire or accident. 

 

!!!!

 

Before using  this  pump,  get  fully  familiar  with  the  precautions  regarding  the  fluid  to  be pumped, and  verify 
the corrosion resistance of the parts that will come into contact with the fluid. NEVER use the pump with any 
fluid  against  which  it  does  not  have  sufficient  corrosion  resistance  or  with  a  fluid  that  poses  a  risk  of 
explosion. If you are unable to verify the corrosion resistance, contact your dealer. Using this product with 
any  fluid  against  which  the  parts  in  contact  with  the  fluid  do  not  have  sufficient  corrosion  resistance  may 
result in damaging the product or leakage of fluid. 

!!!!

 

The running pump may generate loud operating noise. Its level will vary depending upon the conditions of 
use (fluid pumped, supply air pressure and discharge pressure) 

!!!!

 

To drive this product, supply air with minimum moisture content and without any oil must be used. 

!!!!

 

If  a  diaphragm  of  this  pump  is  damaged,  supply  air  may  mix  with  the  fluid  or  the  fluid  may  flow  into  the 
central housing. DO NOT OPERATE THE PUMP if air supply is inadequate or contaminated. 

 Ø 

While operating this product, do NOT put your hand on the inlet port. 

 

Summary of Contents for DM 08/10

Page 1: ...Serial no INSTRUCTION MANUAL Air operated double diaphragm pumps Ver 1 26 Models DM 08 10 DM 10 25 DM 15 55 DM 25 125 DM 40 315 DM 50 565 DM 80 850...

Page 2: ...s Unit 1 Willow Row Longton Stoke on Trent Staffordshire ST3 2PU United Kingdom declares under our sole responsibility that the product Product name Air Operated Double Diaphragm Pumps Models DM serie...

Page 3: ...____________________________________________________ 19 11 Daily check_________________________________________________________________________________ 20 12 Possible problems_________________________...

Page 4: ...operty damage This symbol means a DON T and will be followed by an explanation on what you must not do This symbol means a DO and will be followed by an explanation on what you must do in a specified...

Page 5: ...able strong acid etc with this pump protective measures install a pit a protection box sensors etc must be provided in consideration of possible leakage of fluid Warning signs must be displayed at nec...

Page 6: ...LMECO I AODD DIAPHRAGM PUMPS 5 Names of parts and materials 5 1 DM 08 10 DM 10 25 1 11 24 12 22 5 2 17 7 3 7 9 15 14 25 28 4 27 26 70 13 18 Sleeve with Split connections option code S DM 10 25 only 98...

Page 7: ...20 32 1 08 020 32 14 1 Shaft AISI 304 1 08 24 50 1 08 24 50 NBR 1 08 080 10 1 08 080 10 15 6 O ring FKM 1 08 080 09 1 08 080 09 17 1 Muffler PE porous 1 08 99 35 1 08 99 35 18 1 Air adapter PP 1 08 46...

Page 8: ...MPS 5 2 DM 15 55 DM 25 125 Sleeve with Split connections option code S Flange Connections option code F4 F7 F8 F9 Flange Connections PN10 option code F1 F2 F3 1 2 3 4 5 7 7 9 11 14 15 17 22 24 25 26 2...

Page 9: ...lve PET FKM 1 15 020 32 1 15 020 32 14 1 Shaft AISI 304 1 15 40 50 1 25 40 50 NBR 1 15 080 10 1 15 080 10 15 6 O ring FKM 1 15 080 09 1 15 080 09 16 2 Central housing seal PE 1 15 85 22 1 25 85 22 17...

Page 10: ...PS Sleeve with Split connections option code S Flange Connections option code F4 F7 F8 F9 Flange Connections PN10 option code F1 F2 F3 2 3 4 5 7 7 9 11 12 13 15 14 17 18 22 24 25 26 27 28 16 30 3 1 70...

Page 11: ...020 32 1 40 020 32 14 1 Shaft AISI 304 1 40 40 50 1 50 40 50 NBR 1 40 87 10 1 40 87 10 15 6 O ring FKM 1 40 87 09 1 40 87 09 16 2 Central housing seal PE 1 40 85 22 1 50 85 22 17 1 Muffler PE porous...

Page 12: ...12 I DELLMECO I AODD DIAPHRAGM PUMPS 1 2 3 4 7 7 9 11 12 13 15 14 17 22 24 25 26 27 28 16 30 3 5 18 70 82 83 97 98 99 5 4 DM 80 850...

Page 13: ...Shaft AISI 304 1 80 40 50 NBR 1 40 87 10 15 6 O ring FKM 1 40 87 09 16 2 Central housing seal PE 1 80 85 22 17 1 Muffler Diverse 1 80 99 00 18 1 Air adapter PP 1 80 46 28 PE 2 80 54 20 22 4 Valve seat...

Page 14: ...depending on the construction materials and application parameters The range is from 5 meters dry to 9 meters in a primed condition values calculated for pumping water at 20 degrees Celsius SUBMERGED...

Page 15: ...Exhaust should direct outside not into the fluid in which the pump is submerged The running pump may generate noise Its level will depend upon conditions of use kind of fluid being pumped supply air p...

Page 16: ...port side of the pump 4 Connect a hose on the suction side intake and the discharge port side to the respective vessels WARNING Ground wires must be connected to the piping and any other peripheral eq...

Page 17: ...pressure must be considered WARNING CAUTION A hose must be flexible to absorb pump vibration The hose must be grounded There must be NO external force on any connection part of the pump Be especially...

Page 18: ...ghtened Check that the regulator and the drain valve on the discharge side are closed and that the valve on the suction side is opened Do NOT open the air valve suddenly The supply air pressure may in...

Page 19: ...to purge the pump of remaining fluid as much as possible WARNING CAUTION CAUTION The pump can be shut down with the flow valve closed while air is being supplied However DO NOT leave the pump in this...

Page 20: ...t regular intervals have been changed 12 Possible problems 12 1 Pump does not run Cause Action to take The exhaust port muffler of pump is clogged with sludge Check and clean the exhaust port and muff...

Page 21: ...e Action to take The supply air pressure is low Check the compressor and configuration of air piping Air piping or peripheral equipment is clogged with sludge Check and clean the air piping The discha...

Page 22: ...st the supply air pressure The sleeves are worn out Disassemble the air valve check and clean Replace parts as necessary Connection parts and pump mounting are loose Check each connection part and tig...

Page 23: ...eration Continuous Intermittent ___________Hours day week month Operating air pressure ______________ bar Discharge pressure_________________ bar Discharge volume ________________ l min Suction side__...

Page 24: ...312 426 42 G 1 1 2 109 R 1 2 388 30 60 190 227 DM 50 565 350 385 540 45 G 2 158 R 1 2 485 30 60 270 282 DM 80 850 480 580 800 100 G 3 388 R 3 4 690 40 75 395 495 CAUTION CAUTION WARNING It is the end...

Page 25: ...ting pneumatical with pressure transmitter SC6 SC5 plus stroke counter BF1 Back flushing system hand operated EPDM seals BF2 Back flushing system hand operated FEP FKM seals BF4 Back flushing system p...

Page 26: ...26 I DELLMECO I AODD DIAPHRAGM PUMPS 14 5 Performance curves...

Page 27: ...h damper head in PE conductive 80 C For inflammable liquids as well as for applications in explosion protected areas only dampers made of conductive polymer materials codes R and Z may be used It is n...

Page 28: ...mper head PE conductive 8 08 203 21 8 10 203 21 8 10 203 21 8 25 203 21 8 40 203 21 8 50 203 21 8 80 203 21 42 4 6 8 Housing bolt AISI 304 8 08 542 50 8 10 542 50 8 10 542 50 8 25 542 50 8 40 542 50 8...

Page 29: ...29I DELLMECO I AODD DIAPHRAGM PUMPS PULSATION DAMPER exploded view 41 37 38 39 40 36 42 43 44 43 45 46 46...

Page 30: ...7 21 1 Outlet for Pulsation Damper PTFE conductive 2 08 27 24 2 10 27 24 2 15 27 24 2 25 27 24 2 40 27 24 2 50 27 24 PE 2 15 26 20 2 25 26 20 2 40 26 20 2 50 26 20 PTFE 2 15 26 23 2 25 26 23 2 40 26 2...

Page 31: ...controller itself For further details please refer to the data delivered by the manufacturers of the components The controllers have to be installed in a suitable cabinet Spare part list barrier cham...

Page 32: ...Exploded view barrier chamber system for DM 10 Exploded view barrier chamber system for DM 15 25 40 50 47 58 50 51 56 55 53 54 59 60 57 48 52 63 62 SC5 SC6 only 49 56 61 54 47 48 49 50 only DM 15 DM 2...

Page 33: ...mplete with sensor and stroke counter SC 3 Stroke counting system complete with sensor stroke counter and controller for explosion proof zone In case only the sensor is included code SC1 it has to be...

Page 34: ...d to the pump type and the pump size Spare part list stroke counting Pump size DM 08 DM 10 DM 15 DM 25 DM 40 DM 50 DM 80 Code Pos Quantity Description Material Part no Part no Part no Part no Part no...

Page 35: ...version offers the possibility to use flange connectors according to DIN PN10 options F1 F2 F3 JIS 5K option F4 PN10 DIN 2576 option F7 ANSI 150 RF SO option F8 or PN16 DIN 2277 2278 option F9 For op...

Page 36: ...1 23 2 25 31 23 2 40 31 23 2 50 31 23 S 64 2 Sleeve with split connections PTFE conductive 2 10 31 24 2 15 31 24 2 25 31 24 2 40 31 24 2 50 31 24 16 6 Back Flushing System option code BF1 BF2 BF4 BF5...

Page 37: ...40 072 04 2 50 072 04 PE conductive 2 15 066 21 2 25 066 21 2 40 066 21 2 50 066 21 66 2 Drain plug PTFE conductive 2 15 066 24 2 25 066 24 2 40 066 24 2 50 066 24 PE 2 15 067 20 2 25 067 20 2 40 067...

Page 38: ...the slurry No pressure tank nor pressure transmitter nor speed control are required The complete HP pump works without electric energy End of filtration process When the filter press is filled with th...

Page 39: ...2 50 601 21 PTFE 2 15 601 23 2 25 601 23 2 40 601 23 2 50 601 23 74 2 Pump housing for HP option PTFE conductive 2 15 601 24 2 25 601 24 2 40 601 24 2 50 601 24 75 1 Distance plate short AISI 304 2 1...

Page 40: ...orage or maintenance care 3 Malfunction caused by the use of a fluid that may cause corrosion inflation or dissolution of the component parts of the product 4 Irregularity caused by a repair made by o...

Page 41: ...Notes...

Page 42: ...DELLMECO LTD Unit 1 Willow Row Longton Stoke on Trent Staffordshire ST3 2PU United Kingdom tel 44 1782 793 029 fax 44 1782 501 721 sales dellmeco com www dellmeco com...

Reviews: