3.

Remote Control Operation

The Remote control transmits the signal to system. 

 

Button: press this button to start unit when it is energized or stop the unit when it is 

in operation.   

 

Button: press this button to set unit automatic on and off time 

  Button: press this button to select high speed of fan running (except dry and sleep 

modes)   

Button: press this button to select low speed of fan running. 

Button: press this button to increase temperature or timer setting. 

Button: press this button decrease temperature or timer setting. 

Button: press this button to make Celsius degrees and Fahrenheit degrees interchange. 

Button: 

press this button to select “Cool” mode. 

Button: 

press this button to select “Fan” mode 

Button: 

press this button to select “Dry” or “dehumidifying” mode 

Button: 

press this button to select “Sleep” function under cooling mode. 

Before using your remote, install the AAA batteries into remote control. 

1.

Press and glide the battery cover on the back of the remote control, then you can remove the cover.

2.

Insert two new alkaline AAA batteries into the battery compartment. Be sure to note the proper polarity.

3.

Reattach the battery cover and make sure the locking tab clicks into place.

Notes: 

Use alkaline batteries only. Do not use rechargeable batteries.

When replace batteries, always replace both batteries with new batteries, do not mix old and new batteries.

If  the  air  conditioner  will  not  be  used  for  an  extended  period  of  time,  remove  the  batteries  from  the  remote

control.

CAUTION

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water, do not use the remote 

Be sure to note proper 
polarity of batteries 

Summary of Contents for 048-GM-48334

Page 1: ...ing this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Please keep this Use and Care Manual properly for future refere...

Page 2: ...cal Specification 3 Identification of Parts 4 Operation and Settings 5 Protection 8 Handling and Transportation 8 Installation and Adjustment 9 Drainage Instruction 11 Maintenance and Service 13 End o...

Page 3: ...lectrical shock or injury when using your air conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do n...

Page 4: ...ally adjust the vertical and horizontal louvers slightly to protect louvers from any damage Empty the condensed drainage pan before putting the unit in storage to prolong the unit lifetime end of the...

Page 5: ...ature setting range of this unit is 62 6 86 17 30 This unit is designed with various protection functions such as 24 hour programmable timer auto condensate circle super intelligent temperature sensor...

Page 6: ...el 8 Back shell 9 Central connecting rod 10 Vertical louvers connecting rod 11 Main vertical louver 12 Upper filter 13 Upper drain hole and plug 14 Power cord storage 15 Lower filter 16 Lower drain ho...

Page 7: ...idifying Fan and Sleep modes operations 1 Turn on the unit A Plug in and all indicators will light up on control panel and reminding music will be on display window will show ambient temperature rangi...

Page 8: ...high or low level 2 Fan mode Fan runs at set speed and can be adjusted to high or low compressor do not work Room temperature will automatically show on LED display with range 50 95 10 35 Room temper...

Page 9: ...to select Dry or dehumidifying mode Button press this button to select Sleep function under cooling mode Before using your remote install the AAA batteries into remote control 1 Press and glide the b...

Page 10: ...t off protection function Warning sounds when the water volume reached its alarm level in water tank and unit is automatically stop working both water full indicator and FL on LED window is flashing Y...

Page 11: ...3 laps to keep good connection of exhaust hose assembly and its adapter as Photo 1 2 Installation of the exhaust hose assembly into unit 1 Determine window seal plate position vertical or horizontal d...

Page 12: ...e window in half put the seal plate into window determine in vertical or horizontal position according to window open direction As Photo 2 Extend seal plate parts adjust it to the length of window and...

Page 13: ...talled in good position Lock the screw tightly to avoid fall off Exhaust hose can t be bent or with flexure higher than 45 degrees in order to keep good ventilation of exhaust hose Important notes The...

Page 14: ...e tightly installed to avoid new condensate to wet the floor or carpet when the unit re starts working 2 Continuous drain NOTE You need to buy the PVC drain hose with 13mm by yourself 1 Screw off the...

Page 15: ...force gently into correct place to avoid any damage Notes Do not squash the mesh Do not hit the mesh with sharp objects or brush End of Season Storage 1 Screw off the drain cover and then pull out the...

Page 16: ...rature in cooling mode Change the set temperature Bad cooling effects There is direct sunlight Close the curtain The doors and windows are open the room is crowded or there are other heat sources Clos...

Page 17: ...ioner For specific technical parameters of the model refer to rating label on the product Correct Disposal of this product This marking indicates that the product should not be disposed with other hou...

Page 18: ...ssume for DELLA any additional liability or responsibility in connection with DELLAs merchandise except as described above Implied warranties or merchant ability and fitness of the merchandise are lim...

Page 19: ...WARNING READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE www dellaproductsusa com 909 344 2588...