TDP (W)
Processor model
number
Supported heat sinks
Max DIMM count per CPU
24x 2.5” HDDs enclosure
5118
CPU1: FMM2M
CPU1: 8
35°C/95°F
85 W
5115
CPU1: FMM2M
CPU1: 8
35°C/95°F
4116
CPU1: FMM2M
CPU1: 8
35°C/95°F
4114
CPU1: FMM2M
CPU1: 8
35°C/95°F
4112
CPU1: FMM2M
CPU1: 8
35°C/95°F
4110
CPU1: FMM2M
CPU1: 8
35°C/95°F
4108
CPU1: FMM2M
CPU1: 8
35°C/95°F
3106
CPU1: FMM2M
CPU1: 8
35°C/95°F
3104
CPU1: FMM2M
CPU1: 8
35°C/95°F
70 W
4109T
CPU1: FMM2M
CPU1: 8
35°C/95°F
Expanded operating temperature specifications
Table 23. Expanded operating temperature
Expanded operating temperature
Specifications
Continuous operation
5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to 35°C), the system
can operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, de-rate maximum allowable temperature by 1°C
per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours
–5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C to 35°C), the system
can operate down to –5°C or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable temperature by 1°C
per 125 m above 950 m (1°F per 228 ft).
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event
Log.
24
Technical specifications