![Dell S4100-ON Series Installation Manual Download Page 43](http://html.mh-extra.com/html/dell/s4100-on-series/s4100-on-series_installation-manual_86153043.webp)
Table 14. Environmental parameters
Parameter
Specifications
Operating temperature
5° to 40°C (50°F to 104°F)
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature
–40° to 65°C (–40°F to 149°F)
Storage humidity
5% to 95%, non-condensing
Maximum thermal output
470 W = 1260 BTU/Hr
Maximum operational altitude
10,000 feet (3,048 meters)
Maximum non-operational altitude
39,370 feet (12,000 meters)
Shock
Dell EMC Spec SV0115
Table 15. AC power requirements
Parameter
Specifications
Power supply
100–240 VAC 50/60 Hz
Maximum current draw per switch
4.7A/3.9A at 100/120V AC 2.35A/1.95A at 200/240V AC
Maximum power consumption
370 Watts
Typical power consumption
200 Watts
Table 16. DC power requirements
Parameter
Specifications
Minimum and maximum input voltage range
−40.5V, –48V, -60V
Input power at full load
−40.5V/970W −48V/930W −60V/ 950W, without fan
−40.5V/980W −48V/940W −60V/ 960W, with fan
Input current at full load
−40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan
−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fan
IEEE standards
The S4100–ON Series (S4128F-ON, S4148F-ON, and S4148FE-ON) switch complies with the following IEEE standards:
•
802.1ab (LLDP)
•
802.1ax (Layer 2)
Specifications
43