Port Channel Interfaces
Port channel interfaces support link aggregation, as described in IEEE Standard 802.3ad.
This section covers the following topics:
•
Port Channel Definition and Standards
•
•
•
Configuration Tasks for Port Channel Interfaces
Port Channel Definition and Standards
Link aggregation is defined by IEEE 802.3ad as a method of grouping multiple physical interfaces into a single
logical interface—a link aggregation group (LAG) or port channel.
A LAG is “a group of links that appear to a MAC client as if they were a single link” according to IEEE 802.3ad.
In Dell Networking OS, a LAG is referred to as a port channel interface.
A port channel provides redundancy by aggregating physical interfaces into one logical interface. If one
physical interface goes down in the port channel, another physical interface carries the traffic.
Port Channel Benefits
A port channel interface provides many benefits, including easy management, link redundancy, and sharing.
Port channels are transparent to network configurations and can be modified and managed as one interface.
For example, you configure one IP address for the group and that IP address is used for all routed traffic on
the port channel.
With this feature, you can create larger-capacity interfaces by utilizing a group of lower-speed links. For
example, you can build a 50-Gigabit interface by aggregating five 10-Gigabit Ethernet interfaces together. If
one of the five interfaces fails, traffic is redistributed across the remaining interfaces.
Port Channel Implementation
Dell Networking OS supports static and dynamic port channels.
•
Static
— Port channels that are statically configured.
•
Dynamic
— Port channels that are dynamically configured using the link aggregation control protocol
(LACP). For details, see
Link Aggregation Control Protocol (LACP)
.
There are 128 port-channels with 16 members per channel.
As soon as you configure a port channel, Dell Networking OS treats it like a physical interface. For example,
IEEE 802.1Q tagging is maintained while the physical interface is in the port channel.
Interfaces
465
Summary of Contents for S4048T
Page 1: ...Dell Configuration Guide for the S4048T ON System 9 10 0 1 ...
Page 98: ... saveenv 7 Reload the system uBoot mode reset Management 98 ...
Page 113: ...Total CFM Pkts 10303 CCM Pkts 0 LBM Pkts 0 LTM Pkts 3 LBR Pkts 0 LTR Pkts 0 802 1ag 113 ...
Page 411: ...mode transit no disable Force10 Resilient Ring Protocol FRRP 411 ...
Page 590: ...Figure 67 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 590 ...
Page 646: ...Figure 87 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 646 ...
Page 647: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 647 ...
Page 653: ...Figure 91 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 653 ...
Page 654: ...Figure 92 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 654 ...
Page 955: ...Figure 119 Single and Double Tag First byte TPID Match Service Provider Bridging 955 ...