03.com.redhat01.78b1b8cad821 discovery.sendtargets.auth.password =
password_1
discovery.sendtargets.auth.username = iqn.1984- 05.com.dell:powervault.
123456discovery.sendtargets.auth.password_in = test1234567890
Configure CHAP Authentication On The Host Server Using SUSE Linux
Enterprise Server GUI
1.
Click
Desktop
→
YaST
→
iSCSI Initiator
.
2.
Click
Service Start
, then select
When Booting
.
3.
Select
Discovered Targets
, then select
Discovery
.
4.
Enter the IP address of the port.
5.
Click
Next
.
6.
Select any target that is not logged in and click
Log in
.
7.
Select one of the following:
• If you are not using CHAP authentication, select
No Authentication
. Go to step 8.
or
• If you are using CHAP authentication, enter the CHAP user name and password. To enable Mutual
CHAP, select and enter the Mutual CHAP user name and password.
8.
Repeat step 7 for each target until at least one connection is logged in for each controller.
9.
Go to
Connected Targets
.
10.
Verify that the targets are connected and the status is
true
.
Step 7: Connect To The Target Storage Array From The
Host Server
Connect To The Target Storage Array From the Host Server Using Windows
Server GUI
1.
Click
Start
→
All Programs
→
Administrative Tools
→
iSCI Initiator
.
2.
Click the
Targets
tab.
If previous target discovery was successful, the iqn of the storage array should be displayed under
Targets.
3.
Click
Log On
.
4.
Select
Automatically restore this connection when the system boots
.
5.
Select
Enable multi-path
.
6.
Click
Advanced
and configure the following settings under the
General
tab:
•
Local Adapter
—Must be set to
Microsoft iSCSI Initiator
.
•
Source IP
—The source IP address of the host server you want to connect from.
•
Target Portal
—Select the iSCSI port on the storage array controller that you want to connect to.
•
Data Digest and Header Digest
—Optionally, you can specify that a digest of data or header
information be compiled during transmission to assist in troubleshooting.
•
CHAP logon information
—If CHAP authentication is required, select this option and enter the
Target secret.
•
Perform mutual authentication
—If mutual CHAP authentication is configured, select this option.
43