10
Information Update
E0880
PS REDUNDANCY
LOST
Power supply redundancy has
been lost because a power supply
has been removed from the
system.
Reinstall the power supply to
restore redundancy.
E0D76
BP DRIVE
n
Faulty or improperly installed
hard drive or RAID controller.
See "Troubleshooting SCSI Hard
Drives," "Troubleshooting a RAID
Controller Card," and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide
.
E0D76
SCSI CONNECTOR
SCSI cable is not connected.
See "Troubleshooting SCSI Hard
Drives" in your
Installation
and Troubleshooting Guide
.
EB107
PROC BUS PERR
PROC INIT ERR
PROC PROTOCOL
ERR
Faulty or improperly installed
microprocessor or system board.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide
.
If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide
.
EB107
PROC MACHINE CHK
Faulty or improperly installed
microprocessor or system board.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide
. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide
.
EB107
PROC HOT
Processor is out of acceptable
temperature range and has halted
operation.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide
.
EB10C
ECC UNCORR ERR
ECC UNCORR ERR
BANK #
Uncorrectable ECC errors have
occurred in system memory. The
affected memory bank may be
specified.
See "Troubleshooting System
Memory" in your
Installation
and Troubleshooting Guide
.
Table 1-2.
LCD Status Messages
(continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge 6850
Page 2: ......
Page 19: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 6850 系统 信息更新 ...
Page 32: ...30 信息更新 ...
Page 71: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 6850 システム アップデート情報 ...
Page 87: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerEdge 6850 시스템 설명서 갱신본 ...