Power
Wattage
Maximum
Heat
Dissipation
Voltage
Mini-Tower
265 W
1390 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 5.0 A
Desktop
250 W
1312 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 4.4 A
Small Form
Factor
240 W
1259 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 3.6 A;
100 VAC to 240 VAC, 50 Hz to 60 Hz, 4.0 A
Ultra Small
Form Factor
200 W
758 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 2.9 A
Coin-cell
battery
3 V CR2032 lithium coin cell
NOTE: Heat dissipation is calculated by using the power supply wattage rating.
Physical
Height
Width
Depth
Weight
Mini-Tower
36.00 cm (14.17
inches)
17.50 cm (6.89
inches)
41.70 cm (16.42
inches)
8.87 kg (19.55 lb)
Desktop
36.00 cm (14.17
inches)
10.20 cm (4.01
inches)
41.00 cm (16.14
inches)
7.56 kg (16.67 lb)
Small Form
Factor
29.00 cm (11.42
inches)
9.26 cm (3.65
inches)
31.20 cm (12.28
inches)
5.70 kg (12.57 lb)
Ultra Small
Form Factor
23.70 cm (9.33
inches)
6.50 cm (2.56
inches)
24.00 cm (9.45
inches)
3.27 kg (7.20 lb)
Environmental
Temperature range:
Operating
10 °C to 35 °C (50 °F to 95 °F)
Storage
–40 °C to 65 °C (–40 °F to 149 °F)
Relative humidity (maximum):
Operating
20% to 80% (non-condensing)
Storage
5% to 95% (non-condensing)
Maximum vibration:
Operating
0.26 GRMS
95