background image

DELL™ OPTIPLEX™ 380 TECHNICAL GUIDEBOOK 

 

 

21 

 

Communications 

– Integrated LAN   

Integrated Broadcom57780 Gigabit

1

 LAN

 

MT 

DT 

SFF 

Connector Type 

RJ-45 

Data Rates supported 

10/100/1000M 

Controller Details 

 

Controller bus architecture (example PCIe 1.0a x1) 

PCIe V1.1 x 1 

Integrated memory 

Yes (buffer memory) 

Data transfer mode (example Bus-Master DMA) 

DMA 

Power consumption (full operation per data rate 

connection speed) 

814mW(1000BASE-T) / 450mW(100BASE-T) / 

359mW(10BASE-T) 

Power consumption (standby operation) 

30 mW 

IEEE standards compliance (example 802.1P) 

IEEE802.3, IEEE802.3u, IEEE802.3x 

Hardware Certifications (example FCC, B, GS mark…) 

IEEE 

Boot ROM Support 

Yes 

Network Transfer Mode (example Full Duplex, Half Duplex) 

Full Duplex/Half Duplex

 

 

Network Transfer Rate 

 

10BASE-T (half-duplex) 10 Mbps 

10BASE-T (full-duplex) 20 Mbps 

100BASE-TX (half-duplex) 100 Mbps 

100BASE-TX (full-duplex) 200 Mbps 

1000BASE-T (full-duplex) 2000 Mbps 
Depends on the system environment.

 

Environmental 

 

Operating temperature 

0 to 70°C 

Operating humidity 

NA 

Operating System Driver Support 

Windows XP, Windows Vista , Windows 7 (32bit/64bit), 

Ubuntu (for China Only) 

Manageability (examples WOL, PXE..) 

WoL, PXE 

Management Capabilities Alerting (examples ASF 2.0 
AMT…) 

 

1

 This term does not connote an actual operating speed of 1 Gb/sec. For high speed transmission, connection to a Gigabit Ethernet 

server and network infrastructure is required.

Summary of Contents for OptiPlex 380

Page 1: ...DELL OPTIPLEX 380 TECHNICAL GUIDEBOOK 1 Table of Content DELL OPTIPLEX 780 TECHNICAL GUIDEBOOK INSIDE THE OPTIPLEX 380 DELLTM OPTIPLEXTM 380 ...

Page 2: ...Communications Modem 15 Communications Wireless 15 Audio and Speakers 15 Keyboard and Mouse 15 Security 16 Enterprise Solutions 16 Service and Support 16 Software 16 Detailed Engineering Specifications 17 System Dimensions Physical 17 System Board Connector Maximum Allowable Dimensions 17 System Level Environmental and Operating Conditions 18 Power 19 Audio 20 Communications Integrated LAN 21 Comm...

Page 3: ...lable to meet your changing needs Dell Client Manager allows IT to configure and update multiple desktops simultaneously while monitoring the health of key system components IT can standardize all OptiPlex desktops to a global configuration at time of purchase making it easy to resolve issues and order replacement parts later A 12 month targeted lifecycle and 2 month managed transition period make...

Page 4: ...tch 16 Expansion Card Slots 4 13 Voltage Selector Switch 17 Power Supply Diagnostic Button 14 Power Connector 18 Power Supply Diagnostic Light 1 Optical Drive optional 6 Power Button Power light 2 Optical Drive Eject Button 7 Diagnostic Lights 4 3 Optical Drive Panel 8 Headphone Connector 4 USB 2 0 Connectors 2 9 Microphone Connector 5 Hard Drive Activity Light 10 Network Connectivity Light ...

Page 5: ...ton 7 Network Connectivity Light 3 USB 2 0 Connectors 2 8 Microphone connector 4 Hard Drive Activity Light 9 Headphone connector 5 Diagnostic Lights 4 10 Power Supply Diagnostic Button 14 Chassis Lock Loop 11 Power Supply Diagnostic Light 15 Power Cable Connector 12 Voltage selection switch 16 Back Panel Connectors 13 Cover Release Latch 17 Expansion Card Slots 3 ...

Page 6: ...ton 7 Hard Drive Activity Light 3 USB 2 0 Connectors 2 8 Headphone connector 4 Power button Power light 9 Microphone connector 5 Network Connectivity Light 10 Power Supply Diagnostic Button 14 Voltage Selection Switch 11 Power Supply Diagnostic Light 15 Power Cable Connector 12 Cover Release Latch 16 Back Panel Connectors 13 Chassis Lock Loop 17 Expansion Card Slots 3 ...

Page 7: ...BATTERY 4 Memory module connectors DIMM_1 14 PCI Express x16 card connector SLOT1 5 Memory module connectors DIMM_2 15 PCI card connectors SLOT2 and SLOT3 6 SATA drive connectors SATA0 16 Internal buzzer SPKR 7 SATA drive connectors SATA1 17 Serial PS 2 connector PS2 SER2 8 SATA drive connectors SATA2 18 Fan connector FAN_CPU 9 Front panel connector FRONTPANEL 10 Power connector POWER 1 2 3 4 5 6 ...

Page 8: ...socket BATTERY 4 Memory module connectors DIMM_1 14 PCI Express x16 card connector SLOT1 5 Memory module connectors DIMM_2 15 PCI card connectors SLOT2 6 SATA drive connectors SATA0 16 Internal buzzer SPKR 7 SATA drive connectors SATA1 17 Serial PS 2 connector PS2 SER2 8 Front panel connector FRONTPANEL 18 Fan connector FAN_CPU 9 Power connector POWER 10 Fan connector FAN_HDD 15 1 2 3 4 5 6 7 8 9 ...

Page 9: ...Only Windows Vista operating system 32 bit Windows Vista Business SP1 Windows Vista Home Basic SP1 Windows Vista Business SP1via Windows 7 Professional Downgrade Rights Windows Vista Starter SP1 Limited Countries Only Windows XP operating system 32 bit through downgrade right Windows XP Professional SP3 via Windows Vista Business Windows XP Professional SP3 via Microsoft Windows 7 Professional or ...

Page 10: ... 2 Duo E8500 3 16GHz 6M 1333FSB X X X Intel Core 2 Duo E8400 3 0GHz 6M 1333FSB X X X Intel Core 2 Duo E7600 3 06GHz 3M 1066FSB X X X Intel Core 2 Duo E7500 2 93GHz 3M 1066FSB X X X Intel Core 2 Duo E7400 2 80GHz 3M 1066FSB X X X Intel Pentium Dual Core E6500 2 93GHz 2M 1066FSB X X X Intel Pentium Dual Core E6300 2 8GHz 2M 1066FSB X X X Intel Pentium Dual Core E5400 2 7GHz 2M 800FSB X X X Intel Pen...

Page 11: ...ots 2 2 2 DIMM Capacities Up to 2GB Up to 2GB Up to 2GB Minimum Memory 1GB 1GB 1GB Maximum Memory with 1066 MHz speed memory 4GB 4GB 4GB Configurations 1066MHz Memory configurations 4GB1 DDR3 Non ECC SDRAM 1066MHz 2 DIMM X X X 3GB DDR3 Non ECC SDRAM 1066MHz 2 DIMM X X X 2GB DDR3 Non ECC SDRAM 1066MHz 1DIMM X X X 2GB DDR3 Non ECC SDRAM 1066MHz 2 DIMM X X X 1GB DDR3 Non ECC SDRAM 1066MHz 1 DIMM X X ...

Page 12: ...0 RPM HDD X 320GB1 SATA 7200 RPM HDD X 250GB1 SATA 7200 RPM HDD X 160GB1 SATA 7200 RPM HDD X Optical Drive SFF requires a slimline optical drive DVD RW2 SATA 1 5Gbit s DVD ROM3 SATA 1 5Gbit s 1 For hard drives GB means 1 billion bytes and TB equals 1 trillion bytes actual capacity varies with preloaded material and operating environment and will be less 2 Discs burned with this drive may not be co...

Page 13: ...ON HD 3450 with dual DVI or VGA and S Video Out adapters convert to dual DVI or dual VGA Optional card 256MB nVidia GeForce 9300 GE with dual DVI or VGA and S Video Out adapters convert to dual DVI or dual VGA Optional card Significant of system memory may be allocated to support integrated graphics depending on operating system system memory size and other factors Populating a up graphics card in...

Page 14: ...ne mini jack rear Risers PCI riser card will replace two PCI slots and Combo riser card will replace one PCI and one PCIe slots Combo full height riser with 1 PCI and 1 PCIe connector Optional Dual full height riser with 2 PCI connectors Optional Communications Network Adapter NIC NOTE MT supports full height card DT supports low profile card or full height card with optional riser SFF supports lo...

Page 15: ...profile card MT DT SFF Wireless 1505 Draft 802 11n WLAN Mini Card Desktops Optional full height or low profile card Audio and Speakers MT DT SFF Realtek ALC269Q High Definition Audio Codec Integrated on system board Internal Chassis Speaker Optional Dell AX210 1 2W 2 0 Stereo Speakers Optional Dell AX510 AX510PA FPD Sound Bar Optional Dell AY410 30W 2 1 Stereo Speakers with Subwoofer Optional Keyb...

Page 16: ...ce and Support NOTE For more details on Dell Service Plans please to go to www dell com service service_plans MT DT SFF 1 Year Next Business Day On Site Service 1 1 1 Standard 3 Year Next Business Day On site Service 3 3 3 Optional Software MT DT SFF Dell Client Manager Standard Available via Dell com Dell Control Point Standard security Norton Internet Security 90 Day Trial or optional subscripti...

Page 17: ...ilograms pounds includes packaging materials 19 7 43 5 12 7 28 0 9 7 21 3 Packaging Parameters HxWxD Height inches centimeters 22 38 56 8 20 63 52 4 20 88 50 04 Width inches centimeters 22 25 56 5 20 31 51 6 19 38 49 23 Depth inches centimeters 14 25 36 2 11 75 29 8 10 63 27 System Board Connector Maximum Allowable Dimensions MT DT SFF PCI Slot s Dimensions HxL 2 2 1 Height inches centimeters 4 37...

Page 18: ...ure Operating 10 to 35 C 50 to 95 F Non Operating 40 to 65 C 40 to 149 F Relative Humidity Operating Noncondensing 20 to 80 Max Wet bulb temperature 29 C Non Operating Noncondensing 5 to 95 Max Wet bulb temperature 38 C Maximum vibration Operating 0 25 G at 3 to 200 Hz at 0 5 octave min Non Operating 0 5 G at 3 to 200 Hz at 1 octave min Maximum Shock Operating Bottom half sine pulse with a change ...

Page 19: ...A 5 0v output 17 0 A 15 0 A 15 0 A 15 0 A 15 0 A 16 0 A 12 0v output 16 0 A 13 0 A 7 0 A 14 0 A 18 0 A 16 0 A 17 0 A 5 0v auxiliary output 4 0 A 4 0 A 4 0 A 4 0 A 4 0 A 4 0 A 12 0v output 0 2 A 0 5 A 0 2 A 0 5 A 0 5 A 0 5 A Max total power 255 W 255 W 235 W 255 W 235 W 235 W Max combined 3 3v 5 0v power 121 W 80 W 105 W 91 5 W 98 W 88 W Max combined 12 0v power note only if more than one 12v rail ...

Page 20: ...with 4 channels Number of Bits Audio resolution 16 20 and 24 bit resolution Sampling rate recording playback DACs support Up to 192KHz ADCs support Up to 96KHz Signal to Noise Ratio 98dB Wavetable voices Analog Audio Yes Dolby Digital THX Digital out S PDIF Audio Jack Impedance Microphone 150 kΩ Line In 150 kΩ Line Out 190 Ω Headphone 5 Ω Internal Speaker Power Rating 2W ...

Page 21: ...ications example FCC B GS mark IEEE Boot ROM Support Yes Network Transfer Mode example Full Duplex Half Duplex Full Duplex Half Duplex Network Transfer Rate 10BASE T half duplex 10 Mbps 10BASE T full duplex 20 Mbps 100BASE TX half duplex 100 Mbps 100BASE TX full duplex 200 Mbps 1000BASE T full duplex 2000 Mbps Depends on the system environment Environmental Operating temperature 0 to 70 C Operatin...

Page 22: ...mpliance example 802 1P 802 3 802 2 802 3x 802 1p Hardware Certifications example FCC B GS mark FCC B VCCI B CE Boot ROM Support No Network Transfer Mode example Full Duplex Half Duplex Full Duplex Half Duplex Network Transfer Rate 10BASE T half duplex 10 Mbps 10BASE T full duplex 20 Mbps 100BASE TX half duplex 100 Mbps 100BASE TX full duplex 200 Mbps 1000BASE T full duplex 2000 Mbps Depends on th...

Page 23: ...chronous Error Correction and Data Compression V 44 V 42 V 42bis MNP 2 4 MNP 5 Power Management WOR wake on ring capable Upgradeability Driver upgradeable Video V 80 Synchronous Access Mode SAM can be supported by software applications not driver Operating Temperature 0 50 degree C Operating Humidity 45 degree C 90 max Operating System Support Windows 7 32 64 Vista 32 64 Windows XP 32 64 Operating...

Page 24: ...ed video memory with 2 3 or 4 GB system memory Maximum power consumption 4 0 W Overlay Planes Yes Maximum Color Depth 32 bit Maximum Vertical Refresh Rate 85 Hz Multiple Display Support Yes Operating Systems Graphics Video API Support OpenGL 2 0 DirectX 10 0 Supported Resolutions and Max Refresh Rates Hz Note Analog and or digital Up to 2048x1536 75 Hz Supports flat panels up to 1920x1200 60 Hz or...

Page 25: ...rt Yes Operating Systems Graphics Video API Support D3D and Open GL Supported Resolutions and Max Refresh Rates Hz Note Analog and or digital Max 1920x1440 32bpp 75Hz Min 640x480 8bpp 60Hz External connectors DMS 591 and S video Dimensions of full height card inches centimeters L x H 167 64mm x 120mm Dimensions of low profile card inches centimeters L x H 167 64mm x 85mm Environmental Operating Co...

Page 26: ... Max Refresh Rates Hz Note Analog and or digital Max 1920x1440 32bpp 75Hz Min 640x480 8bpp 60Hz External connectors DMS 59 and S video Dimensions of full height card inches centimeters L x H 167 64mm x 120mm Dimensions of low profile card inches centimeters L x H 167 64mm x 85mm Environmental Operating Conditions Non Condensing Operating Temperature Range 10 50 C Relative Humidity Range 5 90 RH Al...

Page 27: ...V 8A and 12V 1 8A Environmental Operating Conditions Non Condensing Operating Temperature Range 5 to 60 C Relative Humidity Range 20 to 80 non condensing Maximum Wet Bulb Temperature 29 C Altitude Range 50 ft to 10000 ft Environmental Non Operating Conditions Non Condensing Operating Temperature Range 40 to 65 C Relative Humidity Range 10 to 90 non condensing Maximum Wet Bulb Temperature 38 C Alti...

Page 28: ...s 488 397 168 Power Source DC Power Max Idle 7 0W Active 10 0W DC Current 5V 8A and 12V 1 8A Environmental Operating Conditions Non Condensing Operating Temperature Range 5 to 60 C Relative Humidity Range 20 to 80 non condensing Maximum Wet Bulb Temperature 29 C Altitude Range 50 ft to 10000 ft Environmental Non Operating Conditions Non Condensing Operating Temperature Range 40 to 65 C Relative Hu...

Page 29: ...ks 625 142 448 Power Source DC Power Max Idle 7 0W Active 10 0W DC Current 5V 8A and 12V 1 8A Environmental Operating Conditions Non Condensing Operating Temperature Range 5 to 60 C Relative Humidity Range 20 to 80 non condensing Maximum Wet Bulb Temperature 29 C Altitude Range 50 ft to 10000 ft Environmental Non Operating Conditions Non Condensing Operating Temperature Range 40 to 65 C Relative H...

Page 30: ...ks 976 773 168 Power Source DC Power Max Idle 7 0W Active 10 0W DC Current 5V 8A and 12V 1 8A Environmental Operating Conditions Non Condensing Operating Temperature Range 5 to 60 C Relative Humidity Range 20 to 80 non condensing Maximum Wet Bulb Temperature 29 C Altitude Range 50 ft to 10000 ft Environmental Non Operating Conditions Non Condensing Operating Temperature Range 40 to 65 C Relative H...

Page 31: ...48x CD 8x DVD 24x CD Reads 16x DVD 48x CD 8x DVD 24x CD Power Source DC Power Requirements 12V 5V 5V DC Current 1200mA 12V 900mA 5V 1000mA Environmental Operating Conditions Non Condensing Operating Temperature Range 5C to 50C 5C to 50C Relative Humidity Range 20 to 80 RH 20 to 80 RH Maximum Wet Bulb Temperature 29C 29C Altitude Range 200 to 3048 200 to 3048 Environmental Non Operating Conditions ...

Page 32: ...ource DC Power Requirements 12V 5V 5V DC Current 1200mA 12V 900mA 5V 800mA Environmental Operating Conditions Non Condensing Operating Temperature Range 5C to 50C 5C to 50C Relative Humidity Range 20 to 80 RH 20 to 80 RH Maximum Wet Bulb Temperature 29C 29C Altitude Range 200 to 3048m 200 to 3048 Environmental Non Operating Conditions Non Condensing Operating Temperature Range 40C to 65C 40C to 65...

Page 33: ... 0 Enable SATA 1 Enable SATA 2 Enable System Configuration Integrated NIC Enable USB Controller Enable Parallel Port PS 2 Parallel Port Address 378h Serial Port 1 ATUO Miscellaneous Devices Enable Front USB Ports PCI Slots and Audio Video Primary Video Auto Performance Multi Core Support Enable Intel SpeedStep Enable Limit CPUID Value Disable HDD Acoustic Mode Bypass HDD protection Support Disable...

Page 34: ... Auto On Time 08 00 AM Disable Low Power Mode Enable Remote Wake Up Disable Suspend Mode S3 Maintenance Service Tag TBD Asset Tag TBD SERR Messages Enable Image Server Lookup Method DNS Image Server IP 255 255 255 255 Image Server Port 06910 Client DHCP DHCP Client IP 255 255 255 255 Client Subnet Mask 255 255 255 255 Client Gateway 255 255 255 255 License Status TBD Post Behavior Fast Boot Enable...

Page 35: ...w required for proper ventilation Regulatory Compliance and Environmental Product related conformity assessment and regulatory authorizations including Product Safety Electromagnetic Compatibility EMC Ergonomics and Communication Devices relevant to this product may be viewed at www dell com regulatory_compliance The Regulatory Datasheet for this product is located at www dell com regulatory_compl...

Page 36: ...e LpA Table Top Floor Standing Table Top Floor Standing Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Idle 30 3 25 2 24 7 22 9 29 8 25 4 24 4 22 4 HDD Operating 30 3 25 2 24 7 22 9 29 5 24 6 24 5 22 6 ODD Operating 40 4 34 5 34 9 33 0 41 5 36 1 36 2 33 9 90 CPU 31 7...

Page 37: ...p Floor Standing Table Top Floor Standing Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Idle 28 6 24 4 24 7 24 3 28 2 24 2 22 4 20 9 HDD Operating 28 5 24 4 24 9 24 5 28 6 24 8 22 3 21 3 ODD Operating 40 9 36 2 39 2 39 9 41 5 36 9 36 2 34 4 90 CPU 29 3 24 9 25 7 24 ...

Page 38: ...op Floor Standing Table Top Floor Standing Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Operator Position LpA Bystander Position LpA Idle 29 0 24 9 21 7 21 2 31 5 27 4 24 7 23 4 HDD Operating 29 1 25 2 21 7 21 2 32 4 27 8 25 4 23 9 ODD Operating 38 2 32 7 28 7 27 6 38 7 32 9 30 0 28 7 90 CPU 32 1 27 3 23 5 23...