4
Technical Specifications
This chapter lists the S4048–ON specifications.
NOTE: Operate the system at an ambient temperature not higher than 113°F (45°C).
CAUTION: Lithium Battery Caution: To avoid the possibility of an explosion, always replace the
battery correctly.
NOTE: Replace the battery only with the same or an equivalent type. Dispose of the batteries
according to the manufacturer's instructions.
Table 3. S4048–ON Chassis Physical Design
Parameter
Specifications
Height
1.71 inches (43.5 mm)
Width
17.09 inches (434 mm)
Depth
18.11 inches (460 mm)
Chassis weight with factory-installed components
21.7 pounds (approx.) (9.86 kg)
Rack clearance required
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 4. Environmental Parameters
Parameter
Specifications
Operating temperature
32° to 113°F (0° to 45°C)
Operating humidity
5 to 90 percent (RH), non-condensing
Storage temperature
–40° to 158°F (–40° to 70°C)
Storage and non-operating humidity
5 to 95 percent (RH), non-condensing
Maximum thermal output
1153.265 BTH/hr
Maximum operational altitude
10,000 feet (3,048 meters)
Maximum non-operational altitude
No performance degradation to 35,000 feet
(10,668 meters)
Shock
Meets Bellcore Zone 4 earthquake requirements
(MIL-STD-810)
Technical Specifications
23