![Dell Latitude E6400 XFR Service Manual Download Page 80](http://html.mh-extra.com/html/dell/latitude-e6400-xfr/latitude-e6400-xfr_service-manual_78813080.webp)
Dell
™
Latitude™ E6420 XFR Service Manual
Page 80
System Logs
Option
Description
BIOS Events
Allows you to view and clear the System Setup (BIOS) POST events.
DellDiag Events
Allows you to view and clear the DellDiag events.
Thermal Events
Allows you to view and clear the Thermal events.
Power Events
Allows you to view and clear the Power events.
41
Diagnostics
Diagnostic LED Codes The following table shows the possible LED codes that may display when your computer is
unable to complete a power on self test.
Appearance
Description
Next Step
Storage
LED
Power
LED
Wireless
LED
Blinking
Solid
Solid
The microcontroller is
handing control of the
system to the processor.
This code persists if no
processor is detected.
Replace the processor.
Solid
Blinking
Solid
Memory is detected but has
errors.
1. Re-seat the memory.
2. If two modules are installed, remove one and
test. Try the other module in the same slot and
test. Test the other slot with both modules.
3. Replace the memory.
4. Replace the system board.
Blinking
Blinking
Blinking
System Board Error
Replace the System Board.
Blinking
Blinking
Solid
Video Card Error
Replace the System Board.
Blinking
Blinking
Off
Keyboard Error
1. Re-seat the keyboard cable.
2. Replace the keyboard.
Blinking
Off
Blinking
USB Controller Error
Unplug any USB devices attached
Solid
Blinking
Blinking
No SODIMMs are installed
1. Install supported memory modules.
2. If memory is already present, re-seat the
module(s) one at a time in each slot.
3. Try known good memory from another
computer or replace the memory.
4. Replace the system board.
Blinking
Solid
Blinking
Display Panel Error
1. Re-seat the display cable.
2. Replace the display panel.
3. Replace the video card/system board.
Off
Blinking
Blinking
Modem Error
1. Re-seat the modem.
2. Replace the modem.
3. Replace the system board.