Check
List
Task
Topic
☐
11
Install the replacement backplane.
See
on page
86.
For instructions on cable routing, see
☐
12
Install the cooling fan assembly.
See
Install the cooling fan assembly
page 175.
☐
13
Install the air shroud.
See the relevant topic, depending on
your system:
Install the non-GPU air shroud
on page
169
on page 171
☐
14
Install the hard drives.
See
on page 90.
☐
15
Install the system cover.
See
on page
173.
☐
16
Slide the system into the cabinet.
See
Slide the system into the cabinet
page 165.
☐
17
Connect the cable cords.
See
Connect the I/O cables and power
on page 164.
☐
18
Install the front bezel.
See
on page 166.
Perform mandatory software tasks to return the node to operation:
☐
19
Return the node to operation.
See "Return the node to operation" in
the VxFlex Ready Node Field Replacement
Unit Software Guide
.
Drive backplane
The supported drive backplanes are shown here:
Figure 22 8 x 2.5-inch backplane
1. miniSAS hard drive B 1
Hardware FRU procedures
82
VxFlex Ready Node R840
Hardware Field Replacement Unit and Service Manual