Procedure
1. Align the screws with the designated U spaces on the front and rear rack
flanges.
Ensure that the screw holes on the tab of the system retention bracket are
seated on the designated U spaces.
2. Insert and tighten the two screws using the Phillips #2 screwdriver.
Figure 28 Installing screws
Install the system in the cabinet
This procedure is used to install the system in the cabinet.
WARNING
The system is heavy and should be installed in a cabinet by two people. To avoid
personal injury and/or damage to the equipment, do not attempt to install the
system in a cabinet without a mechanical lift and/or help from another person.
Procedure
1. At front of the cabinet, pull the inner slide rails out of the cabinet until they lock
into place.
2U1N Configuration Equipment Installation
Install the system in the cabinet
69