background image

Figure 10. 

5U switch attached FC or iSCSI host server connections

Figure 9. 

2U switch attached FC or iSCSI host server connections

Figure 11.

 2U switch attached FC/iSCSI hybrid host server connections

Figure 13. 

2U direct attached SAS host server connections

Figure 14. 

5U direct attached SAS host server connections

Figure 8. 

5U SAN connections

Figure 16. 

5U AC connections

Figure 17. 

Welcome!

 screen

Figure 12. 

5U switch attached FC/iSCSI hybrid host server connections

SAS

Install and connect each HBA directly to the host ports on the two controllers shown 
in figures 13 and 14.

5  Connect power cables and    

 

power on the storage system

When powering on, ensure the enclosures are powered on and associated with 
data hosts, in the following order (see figures 15 and 16):

1. 

Power on any network switches, routers, or other standalone components.

2. 

Power on any expansion enclosures. Wait until the expansion enclosures are 
completely powered up before powering on the controller enclosure.

3. 

Power on the controller enclosure.

4. 

Power on the host servers (if powered down for maintenance purposes).

Once powered on, the System Power LED on the 2U Ops panel or the Power on/
Standby LED on the 5U Ops panel turns green.

4  Cable host servers to the   

 

 

storage system

The storage system can connect to host servers directly or optionally through 
switches. For information about switch-attach cabling, see the

 Dell EMC 

PowerVault ME4 Series Storage System Deployment Guide. For a list of 
supported HBAs or iSCSI network adapters, see the 

Dell EMC PowerVault ME4 

Series Storage System Support Matrix

.

Fibre Channel

Install and connect each HBA to a switch that is connected to the host ports 
on the two controllers shown in figures 9-12. In hybrid examples, one server and 
switch manages FC traffic, and another server and switch manages iSCSI traffic. 
For FC, each initiator must be zoned with a single or multiple host ports only 
(single initiator/single target or single initiator/multiple target of the same device).

iSCSI

Install and connect each HBA to a switch that is connected to the host ports on 
the two controllers shown in figures 9-12.
For iSCSI, use either dedicated switches for iSCSI traffic, or use VLANs when 
switches are used for different kinds of IP traffic.

6  Configure the storage system

Temporarily set the management host NIC to a 10.0.0.x. address or to the same IPv6 subnet 
to enable communication with the storage system. Use Mozilla Firefox 57 and later, Google 
Chrome 57 and later, or Microsoft Internet Explorer (IE) 10 and 11 browsers to configure the 
storage system.

 

NOTE:

 HTTPS must be used to access the storage system during deployment.

 

NOTE:

 Do not turn on more than one unconfigured controller enclosure at a time to 

avoid IP conflicts.

In a supported web browser:

1. 

Type 

https://10.0.0.2

 to access controller A on an IPv4 network. 

Type 

https://fd6e:23ce:fed3:19d1::1

 to access controller A on an IPv6 network.

2. 

Click 

Get Started

. If a license agreement is displayed, click 

Accept

.

3. 

Set a new username and password for the storage system, then click 

Apply and 

Continue

.

4. 

The 

Welcome!

 panel is displayed (figure 17).

 

NOTE:

 If you have a single controller storage system you must select 

Yes, set my 

system to operate with only a single controller

 on the System Health panel.

5. 

When first accessing Storage Manager, perform a firmware update before configuring 
your storage system. After the firmware update is complete, the 

Welcome!

 panel guides 

you through system setup, storage setup, and host setup.

7  Perform host setup

For more information about performing host setup, see the 

Dell EMC PowerVault 

ME4 Series Storage System Deployment Guide. For a list of supported HBAs or 
iSCSI network adapters, see the 

Dell EMC PowerVault ME4 Series Storage System 

Support Matrix.

 

CAUTION:

 

Ensure that you assign the correct IP addresses to the HBAs 

or network adapters on an iSCSI host. Assigning IPs to the wrong ports 
can cause connectivity issues.

Windows and Linux hosts

Install the HBAs or network adapters and make sure that the latest supported BIOS 
and drivers are installed.
Attach the hosts to the storage system and install MPIO or DM Multipathing on the 
hosts before performing the following steps:

 

NOTE:

 Configure only one host at a time.

Fibre Channel

1. 

Write down the FC WWN of each HBA to complete the Host Setup Wizard

2. 

From the Storage Manager interface, run the Host Setup Wizard.

3. 

Configure MPIO or DM Multipathing for the volumes on the host.

iSCSI

1. 

Assign IP addresses to each iSCSI port to match the subnets for each 
redundant path. 

2. 

Write down the IQNs for each ISCSI initiator/HBA to complete the Host Setup 
Wizard. 

3. 

If needed, install and configure the iSCSI software initiator on the host.

4. 

If using the iSCSI software initiator, it should connect pairs of target/initiator 
addresses for multipath using the initiator applet or CLI.

5. 

Configure MPIO or DM Multipathing for the volumes on the host.

SAS

1. 

Write down the SAS WWN of each HBA to complete the Host Setup Wizard. 

2. 

From the Storage Manager interface, run the Host Setup Wizard. 

3. 

Configure MPIO or DM Multipathing for the volumes on the host.

VMware ESXi Hosts

Install the HBAs or network adapters and make sure that the latest supported BIOS 
and drivers are installed.
Attach the hosts to the storage system before performing the following steps:

 

NOTE:

 Configure only one host at a time.

Fibre Channel

1. 

Write down the FC WWN of each HBA to complete the Host Setup Wizard. 

2. 

From the Storage Manager interface, run the Host Setup Wizard. 

iSCSI

1. 

If using network adapters, create a VMkernel port for each adapter (one 
VMkernel per vSwitch).

2. 

Assign IP addresses for each adapter port to match the subnets for each 
redundant path.

3. 

If using network adapters, add the VMkernel ports to the iSCSI software initiator.

4. 

Write down the IQNs for each ISCSI initiator/HBA to complete the Host Setup 
Wizard.

5. 

From the Storage Manager interface, run the Host Setup Wizard.

SAS

1. 

Write down the SAS WWN of each HBA to complete the Host Setup Wizard.

2. 

From the Storage Manager interface, run the Host Setup Wizard.

For more detailed information, go to 

https://www.dell.com/support

Figure 15. 

2U AC connections

For more detailed setup information, see the 

Dell EMC PowerVault ME4 Series 

Storage System Deployment Guide and Dell EMC PowerVault ME4 Series Storage 
System

 

Administrator’s Guide at 

https://www.dell.com/storagemanuals

.

Summary of Contents for EMC PowerVault ME4 Series

Page 1: ...Setting Up Your Dell EMC PowerVault ME4 Series Storage System 2019 Dell Inc or its subsidiaries 2019 10 ...

Page 2: ...ide of the rear section of the rack bracket d Repeat the above sequence of steps for the companion rail 2 Install the enclosure into the rack a Keeping the enclosure level carefully insert the chassis slides into the rack rails and push fully in b Tighten the mounting screws in the rear kit brackets Figure 1 2U enclosure Figure 2 5U enclosure Expansion cables 1 per expansion module Optional enclos...

Page 3: ...ew Item Description Item Description 1 Fastening screws A 6 Middle slide locking screws 2 Left rail 7 Rear left portion of 5U chassis 3 Rear rack post square hole 8 Front rack post square hole 4 Clamping screw B 9 Front left portion of 5U chassis shown for reference 5 Rail location pins A B C 8 3 4 1 7 2 5 6 1 4 9 5 Fasten the front and rear of the enclosure using the enclosure fastening screws CA...

Page 4: ...odules are not used 3 Connect to the management network Each controller s network port must be connected to a management network The network port provides access to management interfaces and is used to send notifications SNMP traps and support data See figures 7 and 8 1 Connect an RJ45 Ethernet cable to the network port on each controller 2 Connect the other end of each Ethernet cable to a network...

Page 5: ...Storage System Support Matrix Fibre Channel Install and connect each HBA to a switch that is connected to the host ports on the two controllers shown in figures 9 12 In hybrid examples one server and switch manages FC traffic and another server and switch manages iSCSI traffic For FC each initiator must be zoned with a single or multiple host ports only single initiator single target or single ini...

Page 6: ...erver connections Figure 13 2U direct attached SAS host server connections Figure 12 5U switch attached FC iSCSI hybrid host server connections SAS Install and connect each HBA directly to the host ports on the two controllers shown in figures 13 and 14 ...

Page 7: ... to configure the storage system NOTE HTTPS must be used to access the storage system during deployment NOTE Do not turn on more than one unconfigured controller enclosure at a time to avoid IP conflicts In a supported web browser 1 Type https 10 0 0 2 to access controller A on an IPv4 network Type https fd6e 23ce fed3 19d1 1 to access controller A on an IPv6 network 2 Click Get Started If a licen...

Page 8: ...t 4 If using the iSCSI software initiator it should connect pairs of target initiator addresses for multipath using the initiator applet or CLI 5 Configure MPIO or DM Multipathing for the volumes on the host SAS 1 Write down the SAS WWN of each HBA to complete the Host Setup Wizard 2 From the Storage Manager interface run the Host Setup Wizard 3 Configure MPIO or DM Multipathing for the volumes on...

Page 9: ...L Storage ME4series Notes cautions and warnings NOTE Indicates important information that helps you make better use of your product CAUTION Indicates potential damage to hardware or loss of data and tells you how to avoid the problem WARNING Indicates a potential for property damage personal injury or death ...

Reviews: