Specifications
This section lists the S5148F-ON switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 0°C to 45°C (32°F to 113°F).
CAUTION:
Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE:
For RoHS information, see
Restricted Material Compliance
Topics:
•
Chassis physical design
Table 1. Chassis physical design
Parameter
Specifications
Height
1.72 inches (44 mm)
Width
17.1 inches (434 mm)
Depth
18.1 inches (460 mm)
PSU/fan tray handle: 1.57 inches (40 mm)
Chassis weight with factory-installed components
19 lbs (2* PSUs)
8.62 kg (2* PSUs)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 2. Environmental parameters
Parameter
Specifications
Operating temperature
0°C to 45°C (32°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE:
Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity
5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature
-40°C to 70°C (-40°F to 158°F )
Storage humidity
5% to 90%, non-condensing
4
18
Specifications