Table 22. Expansion card slots supported on the system board
PCIe slot
Riser
PCIe slot height
PCIe slot length
Slot width
Slot 1
LOM Riser
Unique to Dell
Unique to Dell
x8 (Gen 3)
Slot 2
Riser 1A
Low-profile
Half-length
x16 (Gen 3)
Slot 3
Riser 2
Low-profile
Half-length
x16 (Gen 4)
a.
The LOM riser contains the OCP network card.
Memory specifications
The VxRail E665 Series appliance supports the following memory specifications for optimized operation.
Table 23. Memory specifications
DIMM type
DIMM rank
DIMM capacity
Minimum RAM
Maximum RAM
RDIMM
Dual rank
16 GB
16 GB
256 GB
32 GB
32 GB
512 GB
64 GB
64 GB
1 TB
Table 24. Memory module sockets
Memory module sockets
Speed
Sixteen 288-pin
3200 MT/s
a.
The clock speed operates at 2933 MT/s if greater than 10 DIMMs are populated.
Storage controller specifications
The VxRail E665 Series appliance supports the following controller cards:
●
Internal controllers
: PowerEdge Expandable RAID Controller (PERC) HBA330
NOTE:
There is no internal storage controller for the VxRail E665N (NVMe) configuration.
●
Boot Optimized Storage Subsystem (BOSS-S1)
: HWRAID 2x M.2 SSDs
●
Onboard controller
: Software RAID (SWRAID) S140
Drives
The VxRail E665 Series appliance supports the following configurations:
●
Hybrid
: Up to 8 x 2.5-inch (SAS, SATA or SSD) front accessible drives in slot 0 to 7
○
Configured as one or two disk groups: 1 cache drive (SAS) + up to 3 capacity drives (HDD) per group
●
All Flash
: Up to 8 x 2.5-inch (SAS, SATA or SSD) front accessible drives in slot 0 to 7
○
Configured as one or two disk groups: 1 cache drive (SAS) + up to 3 capacity drives (SAS/SATA) per group
●
All NVMe
: Up to 10 x 2.5-inch front accessible NVMe drives in slot 0 to 9
○
Configured as one or two disk groups: 1 cache drive (NVMe) + up to 4 capacity drives (NVMe) per group
NOTE:
The front accessible NVMe drives currently utilize PCIe Gen3.
NOTE:
Refer to the VxRail Series procedures in
SolVe Online or the SolVe Desktop application
before performing any
hardware replacement or upgrade activity.
Technical specifications
23