3-2
Dell PowerEdge 4100/180 and 4100/200 Systems Service Manual
1-3-3-1
No DIMM memory
installed
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
1-3-4-1
DRAM failure
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
1-3-4-3
DRAM failure
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
1-4-1-1
DRAM failure
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
1-4-2-1
CMOS failure
Defective system board.
1-4-3-1
Memory controller or
DIMM failure
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
2-2-3-1
Unexpected interrupt
Improperly seated expan-
sion card, or system needs to
be rebooted.
3-2-2-1
4-2-4-4
Gate A20 failure
Defective system board.
4-2-4-3
Keyboard controller
error
Defective DIMMs or system
board. Reseat DIMMs or
replace system board.
Table 3-1. Beep Codes
(continued)
Beep Code
Error
Probable Causes