Table 25 Primary node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 6 - Port 0 A controller port 0 of shelf V1.1
2M
1
I/O 2 - Port 1 B controller port 0 of the highest number shelf in V1
2M
2
I/O 3 - Port 0 A controller port 0 of shelf V2.1
2M
2
I/O 2 - Port 0 B controller port 0 of the highest number shelf in V2
2M
3
I/O 2 - Port 2 A controller port 0 of shelf V3.1
5M
3
I/O 3 - Port 2 B controller port 0 of the highest number shelf in V3
5M
4
I/O 2 - Port 3 A controller port 0 of shelf V4.1
5M
4
I/O 6 - Port 1 B controller port 0 of the highest number shelf in V4
5M
5
I/O 6 - Port 3 A controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
5
I/O 3 - Port 3 B controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
6
I/O 9 - Port 3 A controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
6
I/O 6 - Port 2 B controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Table 26 Standby node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 6 - Port 0 B controller port 2 of shelf V1.1
2M
1
I/O 2 - Port 1 A controller port 2 of the highest number shelf in V1
2M
2
I/O 3 - Port 0 B controller port 2 of shelf V2.1
2M
2
I/O 2 - Port 0 A controller port 2 of the highest number shelf in V2
2M
3
I/O 2 - Port 2 B controller port 2 of shelf V3.1
5M
3
I/O 3 - Port 2 A controller port 2 of the highest number shelf in V3
5M
4
I/O 2 - Port 3 B controller port 2 of shelf V4.1
5M
4
I/O 6 - Port 1 A controller port 2 of the highest number shelf in V4
5M
5
I/O 6 - Port 3
A controller EXPANSION
port of the SSD shelf
or DD Cloud Tier metadata shelf
2M
5
I/O 3 - Port 3
B controller EXPANSION
port of the SSD shelf
or DD Cloud Tier metadata shelf
2M
Connect Cables and Power on
DD9500 and DD9800 with DD Cloud Tier (HA)