![Dell Data Domain DD9500 Hardware Overview And Installation Manual Download Page 75](http://html.mh-extra.com/html/dell/data-domain-dd9500/data-domain-dd9500_hardware-overview-and-installation-manual_85804075.webp)
DD9500 and DD9800 with DD Cloud Tier (Single node)
For a DD9500 and DD9800 system with DD Cloud Tier:
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 6 - Port 0 A controller port 0 of shelf V1.1
2M
1
I/O 2 - Port 1 B controller port 0 of the highest number shelf in V1
2M
2
I/O 3 - Port 0 A controller port 0 of shelf V2.1
2M
2
I/O 2 - Port 0 B controller port 0 of the highest number shelf in V2
2M
3
I/O 9 - Port 2 A controller port 0 of shelf V3.1
2M
3
I/O 3 - Port 1 B controller port 0 of the highest number shelf in V3
2M
4
I/O 2 - Port 2 A controller port 0 of shelf V4.1
5M
4
I/O 3 - Port 2 B controller port 0 of the highest number shelf in V4
5M
5
I/O 2 - Port 3 A controller port 0 of shelf V5.1
5M
5
I/O 9 - Port 0 B controller port 0 of the highest number shelf in V5
5M
6
I/O 6 - Port 3 A controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
6
I/O 3 - Port 3 B controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
7
I/O 9 - Port 3 A controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
7
I/O 6 - Port 2 B controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on
DD9500 and DD9800 with DD Cloud Tier (Single node)
75