Number
Resulting TPID
1
0x0001
10
0x0010
81
0x0081
8100
0x8100
Related
Commands
•
— sets a port (physical ports only) to accept both tagged and
untagged frames. A port configured this way is identified as a hybrid port in report
displays.
•
— specifies a Layer 2 port or port channel as a trunk port to the
Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
C9000 Series
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the
no vlan-
stack trunk
command.
Defaults
Not configured.
Command Modes
INTERFACE
Command History This guide is platform-specific. For command information about other platforms, refer
to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Netowrking OS version history for this command.
Version
Description
9.9(0.0)
Introduced on the C9010.
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
8.2.1.0
Introduced on the E-Series ExaScale. C-Series and S-Series
accept both bytes of the 2-byte S-Tag TPID.
VLAN Stacking
2284
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...
Page 1297: ...Total 5 0 Total 5 active route s using 952 bytes IPv6 Basics 1297 ...