Uplink Failure Detection (UFD)
Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with
NIC teaming, automatic recovery from a failed link.
Topics:
•
•
•
•
•
•
•
•
show running-config uplink-state-group
•
•
•
clear ufd-disable
Re-enable one or more downstream interfaces on the switch/router that are in a UFD-Disabled Error state so
that an interface can send and receive traffic.
C9000 Series
Syntax
clear ufd-disable {interface
interface
| uplink-state-group
group-
id
}
Parameters
interface
interface
Specify one or more downstream interfaces. For
interface
, enter
one of the following interface types:
• 10 Gigabit Ethernet:
tengigabitethernet {
slot/port
|
slot/ port-range
}
• 40 Gigabit Ethernet:
fortyGigE {
slot/port
|
slot/
port-range
}
• Port channel:
port-channel {
1-512
|
port-
channel-range
}
61
Uplink Failure Detection (UFD)
2191
Summary of Contents for C9000 series
Page 1: ...Dell Networking Command Line Reference Guide for the C9000 Series Version 9 10 0 0 ...
Page 394: ...deny 14551 666 Dell Access Control Lists ACL 394 ...
Page 877: ...algorithm FIPS Cryptography 877 ...